NM80Z GAS GENERATOR USER MANUAL UM-NM80Z
NM80Z Gas Generator
UM – NM80Z
Contents
Page No Document History Warranty Statement Safety Notice to Users Declaration of Conformity Air Connection Principle of Operation Commissioning Maintenance Schedule Technical Specifications Pneumatic Diagram Maintenance Log Notes 3 4 4 5 6 7 8 9 11 12 13 14
2
NM80Z Gas Generator
UM – NM80Z
History
Rev. No.
1
Changed
Document Created
Initials
S. Khan
Date
27/08/08
3
NM80Z Gas Generator
UM – NM80Z
Warranties & Liabilities
Warranties and Liabilities
1. The Company warrants that it has title to the Goods. 2. Subject to the provisions of this clause the Company warrants that the Goods shall comply in all material respects with any specification referred to in the Order Confirmation (as the same may be amended) and shall, subject thereto, be free from defects in material and workmanship for the lesser of a period of twelve months from the date of delivery or thirteen months from the date of dispatch from the factory. 3. Save as provided in this clause and except where the Goods are sold to a person dealing as a consumer (within the meaning of the Unfair Contract Terms Act 1977) all warranties, conditions or other terms implied by statute or common law are hereby expressly excluded save to the extent they may not be lawfully excluded. When the Goods are sold to a consumer within the meaning of the Unfair Contract Terms Act 1977 their statutory rights are not affected by the provisions of this clause. 4. In the event of the Customer making a claim in respect of any defect in terms of clause 2 hereof the Customer must:4.1. reasonably satisfy the Company that the Goods have been properly installed, commissioned, stored, serviced and used and without prejudice to the generality of the foregoing that any defect is not the direct or indirect result of lack of repair and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or incorrect spare parts; and 4.2.allow the company to inspect the Goods and/or any installation and any relevant packaging as and when reasonably required by the Company. 5. Subject to the Company being notified of any defect as is referred to in sub-clause 2 hereof within a reasonable time of it becoming apparent and subject always to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or repair the defective Goods or refund a proportionate part of the Price. The Company shall have no further liability to the Customer (save as mentioned in sub-clause 6 hereof). 6. The Company shall be liable to indemnify the Customer in respect of any claim for death or personal injury to any person in so far as such is attributable to the negligence or breach of duty of the Company or any failure by the Company to comply with the provisions of sub-clause 2 hereof. 7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect of any claim by the Customer for costs, damages, loss or expenses (whether direct, indirect, consequential or otherwise) or indemnity in any respect howsoever arising including, but not by way of limitation, liability arising in negligence (other than pursuant to clause 6 above) that may be suffered by the Customer or any third party.
SAFETY NOTICE TO USERS These instructions must be read thoroughly and understood before installation and operation of your Peak Scientific NM80Z. Use of the Generator in a manner not specified by Peak Scientific MAY impair the SAFETY provided by the equipment. When handling, operating or carrying out any maintenance, personnel must employ safe engineering practices and observe all relevant local health and safety requirements and regulations. The attention of UK users is drawn to the Health and Safety at Work Act 1974, and the Institute of Electrical Engineers regulations. WARNING: Nitrogen is not a poisonous gas, but if the concentration in the inhaled air becomes too high there will be a risk of asphyxiation.
4
NM80Z Gas Generator Declaration of Conformity
UM – NM80Z
Declaration of Conformity
5
NM80Z Gas Generator
UM – NM80Z
AIR CONNECTION
Note:- A fittings kit is not provided with this Generator.
The Nitrogen Generator should be connected to a clean, dry, OIL - FREE source of compressed air. A regulated minimum pressure of 120 psig is required. Any doubts as to the suitability of your compressed air supply should be referred to the factory for advice. The generator has a Breathing Air Filter with ¼” BSPT connection to the left side of the unit. The Compressed Air supply should be connected here. This filter will drain moisture and is equipped with an automatic drain. The drain should be led to a convenient place. There are 3-off ¼” BSPT Female bulkhead connections to the right of the unit. To balance each EXHAUST flow only for each Mass spectrometer 4 off ¼” inline flow controller have been provided (if required) with User Manual.
6
NM80Z Gas Generator
UM – NM80Z
Principle of Operation
Peak Scientific Instruments NM80Z Generators utilize two different types of air preparation membranes to produce the required Gas outputs. The Nitrogen side of the generator employs “Hollow Fibre Membrane” Technology to efficiently separate Nitrogen from other gases present in ambient air. An overview of this process can be seen below.
The Zero Air side of the generator uses the latest technology in membrane dryers to produce a clean dry supply of Zero grade air. The pneumatic diagram for the system can be seen below.
Air passes into the system through the Inlet BA Filter which removes bulk moisture and harmful particles. The air is now divided into 2 streams. The first stream is passed through the Nitrogen Membranes to generate a flow of High Purity Nitrogen for the Curtain Gas output. The Nitrogen is then filtered through the RAC Filter to remove any remaining contaminants. The second stream is passed through a Dry point Membranes where moisture and other contaminants are removed from the air before final cleaning by the RAC Filter. This provides Zero Grade Air for Source Gas and Exhaust Gas requirements.
7
NM80Z Gas Generator
UM – NM80Z
Commissioning With the Generator installed (as described earlier), connect compressed air to the unit and turn it ON. Disconnect the Outlet connections to allow the generator to vent to atmosphere until the unit is stabilised. The Generator has been pre-set in the factory to give the specified output flow-rate and pressure in line with known requirements. Once the Membranes reach the design pressures the Generator will stabilise and produce Nitrogen. Maximum purity will be achieved after approximately 1 hour. The generator can then be re-connected to the application. The design of the generator is such that it can deliver up to 104 Litres / min of Zero Grade Air at up to 110 psig with an additional 48 Litres / min of High Purity Nitrogen at 80 psig. Should the demand for gases be less than the rated output flow, or indeed should the demand stop the generator will continue to operate without any problems. Pressure & Flow Settings Output pressures and flow rates are controlled by pressure regulators located behind the front panel as shown below. The Factory settings for the 3 outputs are as follows: -
Flow Regulators
Pressure Regulators
PORT CURTAIN SOURCE EXHAUST Usage / Connection Curtain Gas Ion Source / Nebuliser Exhaust Gas Flow/ Pressure 48 Ltr/min - 80 psig 104 Ltr/min - 110 psig 32 Ltr/min - 60 psig
The above settings should allow the NM80Z to be operated with all standard configurations for the Applied Bio-systems API range of LC/MS/MS instruments. Should the above settings not provide sufficient flow or pressure for your application please contact Peak Scientific for assistance.
8
NM80Z Gas Generator
UM – NM80Z
Maintenance Schedule
WARNING: Servicing and/or repair of the Generator should only be undertaken by a TECHNICALLY COMPETENT PERSON with the Generator in a safely isolated condition.
Due to the simplicity of the design and the small number of moving parts the NM Series Nitrogen Generator will have a long and trouble free life. However as with all scientific and technical equipment it should be regularly inspected and serviced as below BA Inlet Filters RAC Filter Elements Every 12 – months Every 12 - months
BA Inlet Filter Elements
These should be changed at 12 months intervals. In addition filter bowls should be cleaned and, the operation of the auto-drains should be checked, if auto-drain requires replacing. Part # is (02-4485).
FAILURE TO FOLLOW THE PRESCRIBED MAINTENANCE PLAN WILL INVALIDATE THE PRODUCT WARRANTY The Air supply to the Generator MUST be turned OFF and the Generator MUST be de-pressurised prior to attempting to remove ANY filter bowl. Failure to do this may cause injury.
Active Carbon Element (00-4427)
Auto drain (02-4485
Coalescing Element (00-4426)
The filter housing is removed by un-screwing in a counter clockwise direction.
9
NM80Z Gas Generator
UM – NM80Z
Maintenance
RAC Filter The Element is as shown, and should be changed at 12-month intervals. The Air supply to the Generator MUST be turned OFF and the Generator MUST be de-pressurised prior to attempting to remove ANY filter bowl. Failure to do this may cause injury.
Active Carbon Element (00-4425)
The filter housing is removed by un-screwing in a counter clockwise direction
10
NM80Z Gas Generator
UM – NM80Z
Technical Data
General Details
5 oC (41 oF) 30 oC (86 oF) 70% RH(max)
Minimum Operating Ambient Temperature Maximum Operating Ambient Conditions Inlet Conditions (Free of oil and bulk moisture) Minimum Air Inlet Pressure Maximum Air Inlet Pressure Minimum Air Inlet Flow Rate Outlet Gas Maximum Pressure Drop (Outlet-Inlet) δP Maximum Gas Outlet Pressure Maximum Source Gas Outlet Flow (Zero Grade Air) Maximum Exhaust Gas Outlet Flow (Zero Grade Air) Maximum Curtain Gas Outlet Flow (High Purity Nitrogen) Start up time for Purity Particles Serviceable Parts List Breathing Air Inlet Filter Elements Active Carbon Filter Element
120 psig (8.27 Barg) 145 psig (10.0 Barg) 380 l/min (ATP)
8 psig 110 psig 104 Litres/min (ATP) 32 Litres/min (ATP) 48 Litres/min (ATP) 60 minutes 0.01um (Service Kit Part # 08-4631) 00-4426 00-4427 00-4425 (x2)
General Dimensions W x D x H Shipping Weight cm (inches) Kg (lbs) 25 x 25 x 120 (10 x 10 x 44) 27 (60)
11
NM80Z Gas Generator
UM – NM80Z
Pneumatic
Pneumatic Diagram
12
NM80Z Gas Generator
UM – NM80Z
Maintenance log
Maintenance Log
Model- NM80Z
Serial number
Work Done
Remarks
Date
Name
13
NM80Z Gas Generator
UM – NM80Z
Notes
14