Extracted text
Horizen 24
Installation Guide
IMPORTANT
Register product to operate at
www.peakscientific.com/activate
Horizen 24 Installation Guide Rev 3 RSID 5112 EN 05/02/24
IMPORTANT
Register Product to Operate
To begin operation of your unit you will need to register your
generator. You can do so by visiting www.peakscientific.com/activate
or by downloading the Peak Gas App.
Registering will activate your 2 year warranty* - covering every
single component in your generator.
Important!
You must register your generator before nitrogen generation can commence.
In order to be eligible for warranty your generator must be registered to the
end user (not a reseller or distributor) and must have an annual preventative
maintenance arranged within 12 months of the installation date & carried out by
a Peak approved Field Service Engineer. Once registered the warranty will be
honoured for a period of 24 months.**
* 2nd year warranty subject to completion of preventative maintenance visit arranged within 12 months of installation.
For terms and conditions please visit www.peakscientific.com/warranty-statement/
** Call out and labour charges may apply where generator was not purchased directly from Peak
Page 2
Change History
Rev
Comment
Name
Date
1
Initial Release
L. Couttie
22/06/2023
2
Installation Process Update
L. Couttie
13/09/2023
3
Content Updates
L. Couttie
05/02/2024
How to use this Manual
This installation guide is intended to be used as a step by step, quick start guide, to
facilitate installation and configuration.
Please visit www.peakscientific.com/downloads to
download the full User Manual for your gas generator.
Thank you for selecting Peak Scientific to meet your Gas Generation needs, and should
you require any further assistance or support please do not hesitate to contact Peak
Scientific or Peak Partner from which you purchased your Generator.
Page 3
Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this document detail the
most known potential hazards, but by definition cannot be all inclusive. If the user
employs an operating procedure, item of equipment or a method of working which
is not specifically recommended by Peak Scientific, the user must ensure that the
equipment will not be damaged or become hazardous to persons or property.
Symbols
This document uses the following symbols to highlight specific areas important to the
safe and proper use of the Generator
WARNING
A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.
CAUTION
A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the Generator or the Application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the Generator has been removed
before proceeding.
Safety Notice to Users
WARNING
WARNING
These instructions must be read thoroughly and understood before
installation and operation of your Peak Horizen 24 Generator. Use of
the Generator in a manner not specified by Peak Scientific MAY impair
the SAFETY provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
WARNING
Page 4
Fittings Kit
x1
US Mains Cable 240V C19 6-15 04-1024
x1
Flow Control Silencer 02-1096
x3m
1/4” Teflon Tubing 00-1266
x1
UK Mains Cable C19 04-1025
x1
1/4” Compression Fitting
02-4421
x3m
x1
6mm PTFE Tubing 00-1302
EU Mains Cable C19 04-1026
x2
6mm Push Fit Fitting
02-4600
x1
US Mains Cable 120V C19 5-15 04-1035
x3m
6mm PE Tubing 00-1282
Page 5
1.
WARNING
0°
0°
Unpack the generator from the shipping crate, referring to the unpacking instruction
located on the outside of the box, and position on a flat surface in desired area.
The unit should be left to acclimatize for 3 hours.
WARNING the weight of the unit constitutes a two man lift. Safe lifting practices are advised.
2.
02-1096
02-4600
Select the 6mm Push Fit Fitting 02-4600 and attach to the Drain port at the rear of
the generator. Attach the Flow Control Silencer 02-1096 to the Nitrogen port.
Page 6
3.
WARNING
CAUTION
00-1282
Connect the 6mm Polyethylene Tubing (00-1282) to the 6mm Push Fit Fitting (02-4600).
Fit the other end of the tubing to a suitable drain connection or container.
WARNING: The container used MUST be a plastic material and MUST NOT be glass for
safety reasons. The container MUST NOT have an airtight seal as water and air will be
expelled periodically under slight pressure. The container must be placed at ground
level with no elevated or spiralled tubing.
4.
CAUTION
04-1024/04-1025/04-1026/04-1035
Select the appropriate power cable from the fittings kit and plug the IEC 60320/C19
cable into the power input at the rear of the generator.
Page 7
5.
UK
EU
US
110V
US
240V
CAUTION
Plug the mains cable into the corresponding 100VAC 50/60Hz, 120VAC 60Hz OR
230VAC 50/60Hz OR 240V 60Hz single phase power supply.
CAUTION ensure the correct cable has been selected for your electrical supply
Consult the Electrical Requirements section if you are unsure of the requirements of
your generator.
6.
Switch the generator ON using the switch on the rear panel.
Page 8
7.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
Remove the TWO transit bolts from the base of the generator,
turning anti-clockwise using a 13mm spanner.
Press OK on the HMI screen once the bolts have been removed.
8.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
Before the generator will start-up for the first time the user must enter a unique 4-digit
PIN code.
To receive your generator’s unique PIN code, please register on the Peak website
www.peakscientific.com/activate or by downloading the Peak mobile app from the Google Play
Store or Apple App Store. A PIN code may also be requested by phoning the Peak helpdesk. You
will require the generator serial number which is displayed on the screen.
This code is only required on the initial start-up of the unit on the screen on the front
of the generator.
Page 9
9.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
Enter your PIN. If entered incorrectly the screen will briefly display a wrong pass code
warning before allowing a new PIN entry attempt.
10.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
The generator will now initialise.
Page 10
11.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
Press Turn On in the corner of the HMI screen. The outlet pressure reading on the
display will gradually increase to the factory set pressure of 100 psi (6.9 bar). The
outlet pressure can be configured to 116 psi (8.0) bar by pressing the pressure reading
and typing 116 if required.
12.
30
minutes
Leave the generator switched on for a period of 30 minutes to purge the system.
Page 11
13.
After 30 minutes of running, press TURN OFF in the corner of the HMI screen.
Once the pressure gauge on the HMI screen reads 0, the generator can be powered
off and the silencer fitting can be removed from the Nitrogen port.
14.
OR
02-4421
02-4600
Remove the Flow Control Silencer 02-1096 then, depending on the size of the
inlet on the instrument, select either the ¼” Compression Fitting 02-4421 or the
remaining ¼”- 6mm Push Fit Fitting 02-4600.
Page 12
15.
OR
00-1302
00-1266
Attach the appropriate sized Teflon tubing to the fitting attached to the nitrogen
port and connect to the gas inlet of your instrument.
16.
Switch the generator ON using the switch on the rear panel
Page 13
17.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
START UP DISCLAIMER
The generator will be ready to be connected to your LC-MS Instrument after a 30 minute
purge run as LC-MS grade purity will be achieved within this period.
This only applies to the initial start up of the generator. Should your generator be
switched off occasionally for a period of more than 48hrs, we recommend a short purge
run of 30 minutes at 12LPM before resuming testing.
18.
REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]
I’ve got my pin
The pressure display will again gradually increase to the factory set pressure.
Page 14
19.
CONGRATULATIONS
Your Peak Scientific gas generator is now fully installed, operational and ready to
supply gas on demand to your instrument.
Page 15
General Notes
1. The generator is universal voltage and will operate with a 240V, 230V, 120V or 100V
mains supply.
2. The Teflon tube supplied in the fittings kit is to allow the generator to be installed
adjacent to the instrument it is supplying. If the generator is to be installed further
away from the instrument then attention needs to be paid to pressure drops that could
occur. The maximum distance away from the instrument the generator can be placed
still using 6mm (4mm internal diameter) or ¼” (3/16” internal diameter) tubing is 3m.
For further information relating to tubing lengths please refer to the user manual.
Electrical Requirements
Generator
Voltage
Frequency
Plug Type
Horizen 24
100-240V
50-60Hz
UK, EU, US 240V,
US 120V
Please familiarise yourself with the full User Manual available at www.peakscientific.
com/downloads. This includes all other technical specifications, operating
instructions, service requirements, contact details and troubleshooting.
Page 16
Page 17
Page 18
Page 19
Please visit www.peakscientific.com/downloads to
download the full User Manual for your gas generator.
Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries
across every continent around the world. This allows us to provide an industry-leading rapid response
service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top
priority.
To discuss Peak Protected generator cover and payment options speak to your local Peak
Representative or for further information contact: protected@peakscientific.com
Peak Scientific
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Tel: +44 141 812 8100
Fax: +44 141 812 8200
For further information on any of our
generator products please contact
marketing@peakscientific.com
Horizen 24 Installation Guide Rev 3 RSID 5112 EN 05/02/24