Collision Gas Add-on User Manual (EN) 

Full screen preview

Resource tools

Original PDF File

1.9 MB Download

View directly in browser

1.9 MB View in browser
  •  Share
Resource details

Resource ID

4751

Access

Open

Contributed by

Gregor Thompson

Updated date

18 January 23

Review date

31 October 25

Title

Collision Gas Add-on User Manual (EN)

Revision Number

1

Revision Details

Collision Gas Add-on User Manual (EN)

Keywords

Collision Gas Add-on, Collision, User, Manual, UM,

Product Range

Other

Language

UK English

Company Brand

Peak Scientific

Public / Private

public

Extracted text

Collision Gas Add-On
User Manual

Collision Gas Add-On User Manual Rev 1 RSID XXXX EN 22/12/22

Register Product to Operate
To begin operation you will need to register your generator. You can do so by
visiting www.peakscientific.com/activate or by downloading the Peak Genius
App.
Registering will activate your 2 year warranty* - covering every single
component in your generator.






Important!
You must register your generator before nitrogen generation can commence. In
order to be eligible for warranty your generator must be registered to the end
user (not a reseller or distributor) and must have a paid annual preventative
maintenance arranged within 13 months of the installation date & carried out by
a Peak approved Field Service Engineer. Once registered the warranty will be
honoured for a period of 24 months.**
* 2nd year warranty subject to completion of preventative maintenance visit arranged within 13 months of installtion.
For terms and conditions please visit www.peakscientific.com/warranty-statement/
** Call out and labour charges may apply where generator was not purchased directly from Peak

Page 2

Contents
Change History

4

How to use this Manual

4

Warranties and Liabilities

5

Safety Notices

7

Symbols

7

Safety Notice to Users

7

Declaration of Conformity

8

Environmental Declaration
Technical Specification

9
10

Unpacking

11

Fittings Kit Contents

12

Generator Overview

13

General Dimensions

13

Unit Controls

13

Collision Gas Add-On Rear Connections

14

Installation

15

Electrical Connection

16

Start-Up Sequence

17

Product Registration

18

Connecting to the application

20

Tubing Lengths

20

Normal Operation

21

Normal Operation Information Screens

21

Normal Operation Home Screen

21

Unit Information Screen

21

Running Hours Information Screen

21

Unusual Operation

22

Service Requirements

23

Service Schedule

23

Service Indication

24

Peak Protected

25

Cleaning

26

Troubleshooting

27

Page 3

Change History
Rev

Comment

Name

Date

How to use this Manual
This manual is intended for end users and has been written as a reference document
where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, and should
you require any further assistance or support please do not hesitate to contact Peak
Scientific or the Peak Partner from which you purchased your generator.

Page 4

Warranties and Liabilities
Warranty & Liability Coverage
1.

Peak warrants that, subject to the provisions in this statement, purchased Peak generators, whether
purchased directly from Peak or indirectly via an approved, certified and trained distributor or partner
(referred to hereafter as a “Peak Partner”) will comply in all material respects with any specifications
referred to in your customer order confirmation and, subject to installation and operational guidelines
being followed as described in applicable product manuals, shall be free from any defects in quality of
materials or workmanship for a period of one year from the date of installation, provided this takes place
within 3 months of factory dispatch.

2. Where the purchased generator is from the Precision Hydrogen series, Peak further warrants that, subject
to installation and operational guidelines being followed as described in applicable product manuals, the
hydrogen cell shall be free from any defects in quality of materials or workmanship for a total period of
three years (inclusive of warranty period specified in clause 1) from date of installation, provided this takes
place within 3 months of factory dispatch.
3. Where the purchased generator is from the i-Flow 6000 series, Peak further warrants that, subject to
installation and operational guidelines being followed as described in applicable product manuals, the
generator shall be free from any defects in quality of materials or workmanship for a total period of two
years (inclusive of warranty period specified in clause 1) from the date of installation, provided this takes
place within 3 months of factory dispatch and the following provisions have also been met:
a. you must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on or
before the end of the first 12 months of your ownership, and serviced at least once during each subsequent
12 month period thereafter;
b. the generator (and any associated equipment) must have been commissioned by Peak or a Peak
Partner;
c. the feed air or inlet air supply to the generator must comply with ISO 8573-1:2010 Class 1.2.1 at all times;
d. your air compressor, dryer, filtration and oil removal systems must be deemed suitable for use by Peak
or a Peak Partner, and must be changed and serviced regularly, in line with the equipment manufacturer’s
recommended guidelines; and
e. any generator failure or fault that is deemed to have been caused by the failure of any upstream
equipment, component, part or system (such as air compressor, air treatment or filtration) will be excluded
from the warranty described herein.
4. Where the purchased generator is from the Genius XE range, Peak further warrants that, subject to
installation and operational guidelines being followed as described in applicable product manuals, the
generator shall be free from any defects in quality of materials or workmanship for a total period of
two years (inclusive of warranty period specified in clause 1) from the date of registration, provided the
following provisions have also been met:
a. The product must be registered within 12 months of the build date, to the end user (registrations to 3rd
party resellers or other channel partners will not qualify for the warranty extension).
b. You must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on or
before the end of the first 13 months of your ownership
c. The product is required to be serviced in accordance with manufacturer requirements, preventative
maintenance visit must be arranged within 13 months of installation, and the generator must be serviced by
Peak, or a Peak Partner within 13 months of installation.
d. Products purchased via Peak Partners may be subject to call-out and labor charges, which is at the
discretion of the Peak Partner.
5. Peak also warrants that any replacement parts whether purchased (directly from Peak, or via a Peak
Partner) or supplied as part of any remedial action undertaken in line with the provisions of clauses 13 and
14, shall be free from any defects in quality of materials or workmanship for a period of 180 days from the
date of factory dispatch, provided its installation is performed by Peak or a Peak Partner.
6. This warranty does not exclude Peak’s liability in respect of any claim for death or personal injury to any
person, in so far as such can be attributed to negligence or breach of duty of care directly resulting from
failure of Peak to comply with the provisions in clauses 1, 2, 3, 4 & 5.

Page 5

Exclusions & Limitations
7.

This warranty does not cover:
a. damage, deterioration or malfunction resulting from an alteration or modification to a generator which
has not been carried out by Peak or a Peak Partner;
b. damage, deterioration or malfunction resulting from what Peak reasonably believes to be abuse, or
misuse of a generator by you or any third party;
c. liability for accident or neglect (other than pursuant to clause 6);
d. maintenance or repairs which have not been carried out by Peak or a Peak Partner;
e. operation of a generator or exposure of a generator to environmental conditions that fall out-with
operational guidelines as specified in the applicable product user manual; and
f. lightning, power surges or any other acts of God or nature.

8. This warranty is non-transferrable. Only the original owner of the generator may benefit from the terms
within this statement.
9. Peak shall not be liable in respect of any claim made for costs, damages, losses or expenses (whether
consequential, direct, indirect or otherwise) or in any respect howsoever arising including, but not limited
to, liability from accident or negligence (other than pursuant to clause 6) that may be suffered by you or
any third party.
10. No person or entity is authorised to change the terms and conditions outlined in this warranty statement in
any respect, or to create any additional obligations or liabilities for any party involved.
11. This warranty statement supersedes any and all prior warranty agreements between the parties and
constitutes the complete, final and exclusive understanding of the parties with respect to the subject
matter. All prior negotiations, representations, or promises, whether oral or written, of either party shall be
deemed to have been merged herein.
12. If any part of this warranty statement is invalidated, for whatever reason, such part will be deleted and the
rest shall remain unaffected, continuing to be in full force and effect.

Delivery of Warranty Service
13. Subject to clause 14, and:
a. Peak being notified by you, within the duration of the applicable warranty period, of any defect that you
think is subject to any warranty valid under clauses 1, 2, 3, 4 or 5; and
b. Peak being permitted to inspect the generators, parts and their installation (along with any relevant
packaging)
Peak shall at its option repair or replace defective generators or parts (including, if necessary, any moving
parts and irrespective of runtime). No additional charges will apply, for parts or delivery and, where
applicable, labour or travel. Peak will endeavour to deliver this service within 3 working days of your
notification.
14. Where, in Peak’s reasonable opinion, a defect is subject to an exclusion described in clause 7, Peak reserves
the right to charge for parts or delivery and, where applicable, you may also be charged by Peak for call
out, labour or travel in respect of any repair or replacement which you authorize Peak to carry out.

Page 6

Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this manual refer to the most
likely potential hazards, but by definition cannot be all inclusive. If the user employs
an operating procedure, item of equipment or a method of working which is not
specifically recommended by Peak Scientific, the user must ensure that the equipment
will not be damaged or become hazardous to persons or property.

Symbols
This manual uses the following symbols to highlight specific areas important to the safe
and proper use of the generator.

WARNING

A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.

CAUTION

A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the generator or the application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed
before proceeding.

Safety Notice to Users

WARNING

WARNING

These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.

WARNING

This equipment is for indoor use only.
CAUTION

Page 7

Declaration of Conformity
Unit currently under accreditation.
We
Peak Scientific Instruments Ltd.
Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:
Equipment:

Nitrogen Gas Generator

Models: Fusion 2020

To which this declaration relates, is in conformity with the applicable EC directives,
harmonized standards, and other normative requirements.
•

Low Voltage Directive 2014/35/EU
EN 6-1: 2010 Safety Requirements for Electrical Equipment for Measurement, Control
and Laboratory Use.

•

Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for Measurement, Control and Laboratory Use
- EMC Requirements.

•

FCC47 CFR Part 15 Class A
Unintentional radiators; Conducted and Radiated emissions limits.

All evaluation, testing and certification issued by:
Nemko Canada Inc.

Eurofins (York) Ltd.

303 River Road

Unit 1, Grangemouth Technology Park

Ottawa, Ontario

Earls Road, Grangemouth,

Canada, K1V 1H2

United Kingdom, FK3 8UZ



Signed: Name:

Fraser Dunn

Date:

Design Engineering Manager

Page 8

11/01/2021

Position:

Environmental Declaration
Unit currently under accreditation.
We
Peak Scientific Instruments Ltd.
Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:
Equipment:

Nitrogen Gas Generator

Models:

Genius XE SMZ

Is fully compliant with the following Directives.
•

2012/19/EU

WEEE (Waste of Electrical and Electronic Equipment)

•

2011/65/EU & 2015/863

RoHS (Restriction of Hazardous Substance)

Peak Scientific Instruments Ltd fully complies with its obligations towards the European
WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These
obligations are being met within the B2B compliance group.
Peak Scientific Instruments Ltd, herewith confirm that as a manufacturer of articles we
conform to the European Parliament and Council Directives, 2011/65/EU for the original
6 restricted substances listed in the Restriction of Hazardous Substances (RoHS)
Directive and Commision Delegated Directive (EU) 2015/863 to include 4 additional
restricted substances. Peak Scientific Instruments LTD have developed all reasonable
'due diligence' controls to ensure that our products comply with the principles and
requirements of the RoHS (Restriction of Hazardous Substances) Directives.
Where a specific certificate of compliance is required, this can be requested, on
a product serial number basis, directly from Peak Scientific Instruments Ltd, by
contacting us through our website at www.peakscientific.com

Signed: Name:

Fraser Dunn

Date:

Design Engineering Manager

Page 9

11/01/2021

Position:

Technical Specification
Environment
Collision Gas
Minimum Operating Ambient Temperature

5°C (41°F)

Maximum Operating Ambient Temperature

35°C (95°F)

Maximum Altitude
Maximum Relative Humidity

3000 m
80% Non-Condensing

Minimum Storage Temperature*

-20°C (-4°F)

Maximum Storage Temperature*

60°C (140°F)

*NOTE – When taken out of storage the Generator should be allowed to acclimatize at room temperature for a minimum of 3 hours before operation.

Generator Outlets
Nitrogen Maximum Flow
Particles
Phthalates
Suspended Liquids
Gas Outlets

0.2 L/min @ 5.5 Bar (80 PSI)
<0.01µm
NONE
NONE
1 x ¼” BSPP

Electrical Requirements
Voltage
Frequency
Current
Input Connection
Power Cord
Pollution Degree
Installation / Over Voltage Category

240VAC / 100VAC
50/60 Hz
0.2A
C14 Plug
C13 socket to local connection
2
II

General
Dimensions cm (inches) WxDxH
Generator Weight Kg (lbs)
Shipping Weight Kg (lbs)

Page 10

36 x 42.5 x 16.5 cm (14.2 x 16.7 x 6.5")
13.7kg (30.2lbs)
TBC

Unpacking
Although Peak Scientific takes every precaution with safe transit and packaging, it is
advisable to fully inspect the unit for any sign of transit damage.
Check ‘SHOCKWATCH’ and ‘TIP-N-TELL’ labels for signs of rough handling prior to
unpacking.

Any damage should be reported immediately to the carrier and Peak Scientific or the
Peak Partner from where the unit was purchased.
Follow the unpacking instructions posted on the side of the crate.
Please save the product packaging for storage or future shipment of the generator.
Note: Included with the generator is a “Fittings Kit” containing mains power leads for
UK, EU & US and also all the required fittings and warranty registration card. Be careful
not to discard these with the packaging.

Page 11

Fittings Kit Contents
Supplied in the Fittings Kit are all the fittings required to connect the generator to the
application. The contents of the Fittings Kit are as follows:
1/4” Teflon Tubing x 3m

x1

2. 6mm FEP Tubing x 3m

x2

1.

3. 1/4" Compression Fitting x 1
4. 6mm Push-Fit Fitting

x 2



5. Output Split Assembly x 1
6. UK Mains Power Cable 230v

x1

7. EU Mains Power Cable 230v

x1

8. US Mains Power Cable 110v

x1

9. US Mains Power Cable 230v

x1

All of the generators output ports are located on the output panel at the rear of the
unit.

Page 12

Generator Overview
General Dimensions
360mm /14.2"

415mm / 16.3"

165mm / 6.5"

WARNING

WARNING

The generator must always be placed on a flat, level surface. Failure
to do so will affect the performance of the generator. It can be also
placed on the top of Genius XE35/XE70
The generator should be situated in a well ventilated environment, with
at least 75mm (3”) air gap all around it and should be positioned such
that it can be easily disconnect from the mains supply if required.

Unit Controls
HMI Screen

Page 13

Collision Gas Add-On Rear Connections

Gas Outlet
Gas Inlet
Power Switch
IEC Power Inlet

Ensure all inlets and outlets are connected to correct sources and applications
WARNING

All Connections should only be carried out by trained personnel
WARNING

Generator must be switched off and unplugged prior to any cleaning
or maintenance operations
WARNING

Page 14

Installation
Generator Environment
The generator is designed for indoor use only. It should be installed adjacent to the
application(s) it is supplying and close as possible to the gas supply (Genius XE35/
XE70. If this is not convenient then the unit can be sited elsewhere. Consideration
should be made of the lengths of pipe runs as pressure drops can result from extended
runs of pipe. See page 20 for guidance on tubing lengths greater than 3m.
The vent should not be blocked or restricted in any way. An air gap of 75mm (3”)
should be maintained down both sides and 100mm (4") at the rear of the unit. Please
refer to the drawing on page 13 for the general dimensions of the unit.
Please ensure generator is situated in a well ventilated environment and is positioned to
permit easy disconnection if required.
Minimum Operating Ambient Temperature:

5 °C (41 °F)

Maximum Operating Ambient Temperature:

35 °C (95 °F)

Page 15

Electrical Connection
Connect the generator to an appropriate single-phase supply, refer to the generator
serial plate for input specification and ensure your supply matches the requirements.
If an appropriate mains power cords is not supplied or a substitute one is used then
ensure that all components of it the plug, cord and connector have adequate ratings
for the generator and appropriate approvals for the country of use. Failure to do so
could cause damage to the generator or risk overloading of the power cord

WARNING

This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE
EARTHED. Before connecting the unit to the mains supply, please
check the information on the serial plate. The mains supply must be of
the stated AC voltage and frequency.

EARTH/GROUND (E):-

Green & Yellow

or

Green

LIVE (L):-

Brown

or

Black

Neutral (N):-

Blue

or

White



Electrical requirements are 240VAC / 100VAC nominal +/- 10%. Running at voltages
outwith this is not recommended. Extended periods at extremes can have a detrimental
effect on the operation and life of the generator.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.
WARNING

Page 16

Start-Up Sequence
Connect the Collision Gas unit to the gas supply source (Genius XE35/XE70).

CAUTION

Switch the unit on using the power switch on the rear panel of the
generator - do not connect it to the application for 30 minutes to allow
the system to purge.

Collision Gas add-on unit will then go through Product Registration. This is detailed on
the next page.

Page 17

Product Registration
Before the generator will start-up for the first time the user must enter a unique 4-digit
PIN code.
To receive your generator’s unique PIN code, please register on the Peak website
www.peakscientific.com/activate or download the Peak mobile app from the Google
Play Store or Apple App Store. A PIN code may also be requested by phoning the Peak
helpdesk.
This code is only required on the initial start-up of the unit.

Collision Gas Add-On Registration
1. Press the 'I've got my pin' button and select the language on the screen on the
front of the generator.

2. Enter your PIN.

3. The unit will then go through initialisation phase for 3 hours.

Page 18

4. Upon completion of the initialisation phase, the screen will display the below, home screen.
Status on the bottom of the screen should display Ready.

Page 19

Connecting to the application
Once the initial purge run of 30 minutes has completed, generator can be connected to
the application. Please note that this generator requires 3 hours to reach the purity.
After this time, gas will be delivered to the outlet port. Attach the ¼” compression
fittings to the outlet of the generator. Using suitable tubing, connect the outlets of the
generator to the inlets on the application.
If you require more tubing than is supplied please refer to the Tubing Lengths section.
For connection to GC applications, we would recommend laboratory grade copper or
stainless steel tubing.

CAUTION

Once the tubing is connected to the application, please ensure that it
is thoroughly checked for being leak-tight. Even the slightest leak in
the gas supply between the generator and the application can lead to
a reduction in efficiency.

Tubing Lengths

CAUTION

The diameter of the tubing which will be connected to the gas outlets
is important and is determined by the length of tubing required. Failure
to follow these recommendations could lead to pressure between
generator and application.

For connection between Nitrogen generator and Collision Gas Add-on unit:
<3 meters:

Use 6mm OD / 4mm ID FEP tubing.

Tubing length between the nitrogen source and Collision Gas unit should be no longer
than 3 meters.
For connection between Collision Gas Add-on and the application:
<3 meters:


< 10 meters:
>10 metres:


Use 6mm OD / 4mm ID FEP or 1/4" OD / 3/16" ID PTFE or 1/8"
copper / stainless steel tubing (1/8" tubing or fittings not
supplied in the fittings kit).
Use 6mm OD / 4mm ID FEP or 1/4" OD / 3/16" ID PTFE
Please contact Peak Scientific with the relevant distance and we
will calculate the flow resistance and the tubing size required.

Keep the connections and bends to a minimum.

Page 20

Normal Operation
The Collision Gas add-on is specifically designed to minimize operator involvement. The
generator will produce Nitrogen with the purity <5PPM at the flow and pressure specified
in the Technical specification section of the user manual.
To ensure that the generator operates optimally, it should be installed and maintained
according to information provided in this user manual.
Collision Gas Add-on generator input gas must be supplied by Genius XE35/XE70 Peak
nitrogen generator and cannot operate as stand alone unit.
The generator will automatically produce the factory set pressure as detailed in the
technical Specifications. The outlet flow rate is 0.2LPM and cannot be changed

Normal Operation Information Screens
Normal Operation Home Screen

Unit Information Screen

Running Hours Information Screen
Service - number of day left till next
service
Production - number of nitrogen
generation days
Generator - number of days that the
generator is powered on

Page 21

Language Selection Screen

Unusual Operation
If at any time the Generator begins to emit excessive noise or vibration, then it should
be switched off and you should contact your local representative or Peak Scientific as
soon as possible.

Page 22

Service Requirements
Service Schedule
Purchase Interval

Component

24 Months

Collision Gas Add-on 24 Month Service Kit*

Visit

www.peakscientific.com/ordering
48 Months

Collision Gas Add-on 48 Month Service Kit*

* Please quote your generator serial number when ordering your Maintenance Kit to
ensure selection of the appropriate kit for your generator.

Page 23

Service Indication
The generator will notify the user of the service interval.
The generator has the following Service Indication Stages:-

Stage 1 
23 months after installation, the orange service indicator will show on the display.
This is to make the user aware that a service of the generator is due and should be
planned at the earliest convenience. The generator will continue to operate as normal
with the service indicator on.

Stage 2 
If the service is not completed, the generator will continue to run. After 4 weeks, the
service overdue indicator will change to red.
This is to make the user aware that the service of the generator is now overdue and
must be completed immediately to ensure the continuous trouble free operation of the
generator.

Service Indication Reset
Once the service has been completed the Service Indication can be reset through the
service interface. This will be performed by the Peak Service Engineer or trained service
representative that completes the service operation.

Page 24

Peak Protected
With Peak Scientific you invest in not only a product but peace of mind. With a network of
certified Peak engineers stationed throughout the globe, Peak’s rapid response team are
never far away and our commitment is to keep your generator running day in, day out,
protecting your laboratory workflow.

[Peak Protected] can provide…

Installation

A dedicated Peak engineer will visit
your lab to install and setup your
generator

IQ/OQ

Certified assurance for applications
requiring documented qualification

Complete plan

Swift response by a Peak Service
Engineer within 72 hours & planned
preventative maintenance

Spares

Genuine Peak parts with express
delivery, ensuring optimal
performance and lifetime

Premium Protected

Guaranteed rapid on-site response
within 24 hours & planned
preventative maintenance

Technical Support Hotline

Around the clock support by phone
or online with our global technical
helpdesk

To find out more about protecting your investment visit: www.peakscientific.com/protected

Page 25

Cleaning
Clean the outside of the generator only using warm soapy water and a clean damp
cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.
Cleaning should only be undertaken with the power switched off and
the power cord removed from the rear of the generator.

CAUTION

Under no circumstances should any solvents or abrasive cleaning
solutions be used as these can contain fumes that could be harmful to
the generator.
Care should be taken with Leak Detections Liquids.

CAUTION

Page 26

Troubleshooting
Problem

The Generator will not switch on.

Purity isn’t reached.

The application is reporting low pressure.

Service indicator on the screen is active 

Overdue service indicator on the screen is active 

Page 27

Possible Solution
•

Ensure power cord is plugged into the Generator
and that the power socket is turned on.

•

Check the fuse in the power cord plug.

•

Contact your service provider.

•

Check for leaks between generator and instrument

•

Contact your service provider

•

Check output pressure gauge on Genius XE35/
XE70.

•

Check for leaks between the the supply and the
generator but also between generator outputs and
consuming instrument.

•

Contact your service provider.

•

The generator is due for service. Contact your
service provider.

•

Refer to Service Indication section of this manual for
further information.

•

The generator is overdue for service.

•

Contact your service provider urgently.

•

Refer to Service Indication section of this manual for
further information.

Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries
across every continent around the world. This allows us to provide an industry-leading rapid response
service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top
priority.
To discuss Peak Protected generator cover and payment options speak to your local Peak
Representative or for further information contact: protected@peakscientific.com

Peak Scientific
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Tel: +44 141 812 8100
Fax: +44 141 812 8200
For further information on any of our
generator products please contact
marketing@peakscientific.com
Collision Gas Add-On User Manual Rev 1 RSID XXXX EN 22/12/22