Solaris XE
User Manual
Copyright © Peak Scientific Instruments Ltd 2024 — Solaris XE User Manual Rev 9 RSID 2302 EN —25/06/2024
Contents
Change History
3
How to use this Manual
3
Warranties and Liabilities
4
Safety Notices
5
Symbols
5
Safety Notice to Users
5
EU Declaration of Conformity
6
UK Declaration of Conformity
7
WEEE Compliance Statement
8
CSA Compliance Statement
9
European Union (EU) and United Kingdom (UK) Class A Compliance statement
10
FCC Class A Compliance Statement
10
Industry Canada Class A emission compliance statement
10
Korea Communications Commission (KCC) statement
10
Technical Specification
11
Solaris XE
11
Unpacking
12
Fittings Kit Contents
13
Unpacking Instructions
13
Installation
14
Generator Environment
14
Generator Overview
15
Solaris XE General Dimensions
15
Solaris XE Rear Connections
16
Electrical Connection
17
Air Purity
18
Class 1 Particulate
18
Class 4 Water
18
Class 1 Oil
18
Connecting to the application
18
Tubing Lengths
18
Start-Up Sequence
19
Setting the Output Pressure
20
Service Requirements
21
Service Schedule
21
Peak Protected
22
Cleaning
23
Troubleshooting
24
Register Warranty
25
Supported Maintenance Guide
26
Service Parts List
30
Page 2
Change History
Rev
Comment
Name
Date
1
Initial Release
Liam Couttie
14/03/2018
2
Tech Spec Update
Liam Couttie
02/04/2018
3
Updates to Incorporate CSA Feedback
Liam Couttie
26/07/2018
4
5
Env. Declaration Updates
Purity Update
Liam Couttie
Liam Couttie
24/06/2019
6
Declaration Updates
Cleo Denholm
31/08/2021
7
Declaration Updates
Liam Couttie
04/10/2023
8
Declaration Updates
Liam Couttie
20/02/2024
9
SMG Added
Cleo Denholm
18/04/2024
21/07/2020
How to use this Manual
This manual is intended for end users and has been written as a reference document
where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, and should
you require any further assistance or support please do not hesitate to contact Peak
Scientific or the Peak Partner from which you purchased your generator.
Page 3
Warranties and Liabilities
1. The Company warrants that it has title to the Goods.
2. Subject to the provisions of this clause the Company warrants that the Goods
shall comply in all material respects with any specification referred to in the Order
Confirmation (as the same may be amended) and shall, subject thereto, be free
from defects in material and workmanship for the lesser of a period of twelve
months from the date of delivery or thirteen months from the date of dispatch
from the factory.
3. Save as provided in this clause and except where the Goods are sold to a person
dealing as a consumer (within the meaning of the Unfair Contract Terms Act
1977) all warranties, conditions or other terms implied by statute or common
law are hereby expressly excluded save to the extent they may not be lawfully
excluded. When the Goods are sold to a consumer within the meaning of the Unfair
Contract Terms Act 1977 their statutory rights are not affected by the provisions of
this clause.
4. In the event of the Customer making a claim in respect of any defect in terms of
clause 2 hereof the Customer must.
1. Reasonably satisfy the Company that the Goods have been properly installed,
commissioned, stored, serviced and used and without prejudice to the generality
of the foregoing that any defect is not the direct or indirect result of lack of repair
and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or
incorrect spare parts
2. Allow the company to inspect the Goods and/or any installation and any relevant
packaging as and when reasonably required by the Company.
5. Subject to the Company being notified of any defect as is referred to in sub-
clause 2 hereof within a reasonable time of it becoming apparent and subject always
to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or repair
the defective Goods or refund a proportionate part of the Price. The Company shall
have no further liability to the Customer (save as mentioned in sub-clause 6 hereof).
6. The Company shall be liable to indemnify the Customer in respect of any claim
for death or personal injury to any person in so far as such is attributable to the
negligence or breach of duty of the Company or any failure by the Company to
comply with the provisions of sub-clause 2 hereof.
7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect
of any claim by the Customer for costs, damages, loss or expenses (whether direct,
indirect, consequential or otherwise) or indemnity in any respect howsoever arising
including, but not by way of limitation, liability arising in negligence (other than
pursuant to clause 6 above) that may be suffered by the Customer or any third party.
Page 4
Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this manual refer to the most
likely potential hazards, but by definition cannot be all inclusive. If the user employs an
operating procedure, item of equipment or a method of working which is not specifically
recommended by Peak Scientific, the user must ensure that the equipment will not be
damaged or become hazardous to persons or property.
Symbols
This manual uses the following symbols to highlight specific areas important to the safe
and proper use of the generator.
WARNING
A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.
CAUTION
A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the generator or the application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed
before proceeding.
Safety Notice to Users
WARNING
WARNING
These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.
WARNING
Page 5
EU Declaration of Conformity
We
Peak Scientific Instruments Ltd.
Of
Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Hereby declare that, this declaration of conformity is issued under the sole
responsibility of the manufacturer.
Equipment Type:
Nitrogen Generator
Model Designator:
Solaris XE
To which this declaration relates, is in conformity with the following applicable EU
Directives, harmonized standards, and other normative requirements.
•
Low Voltage Directive 2014/35/EU
EN 61010-1: 2010+ A1:2019 Safety Requirements for Electrical Equipment for
Measurement,
Control and Laboratory Use.
•
Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2021 Electrical Equipment for Measurement, Control and Laboratory Use
– EMC Requirements. (Class A)
•
Restriction on the use of certain hazardous substances in electronic equipment
(RoHS) Directive 2011/65/EU as amended by EU 2015/863.
Signed for and on behalf of Peak Scientific by
Signed:
Name:
Fraser Dunn
Position:
Design Engineering Manager
Peak Scientific Instruments ltd,
Inchinnan, Renfrew, Scotland, PA4 9RE, UK.
Date:
5th January 2024
Page 6
UK Declaration of Conformity
We
Peak Scientific Instruments Ltd.
Of
Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE
Hereby declare that, this declaration of conformity is issued under the sole
responsibility of the manufacturer.
Equipment Type:
Nitrogen Generator
Model Designator:
Solaris XE
To which this declaration relates, is in conformity with the following applicable UK
Statutory Instruments, Standards and other normative requirements.
•
The Electrical Equipment (Safety) Regulations 2016 (SI 2016 / 1101) as amended.
BS61010-1:2010+ A1:2019 Safety Requirements for Electrical Equipment for
Measurement Control and Laboratory Use.
•
The Electromagnetic Compatibility Regulations 2016 (SI 2016 / 1091) as amended.
BS61326-1:2021 Electrical Equipment for Measurement , Control and Laboratory Use
– EMC Requirements. (Class A)
•
The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012 (SI 2012 / 3032) as amended.
Signed for and on behalf of Peak Scientific by
Signed:
Name:
Fraser Dunn
Position:
Design Engineering Manager
Peak Scientific Instruments ltd,
Inchinnan, Renfrew, Scotland, PA4 9RE, UK.
Date:
5th January 2024
Page 7
WEEE Compliance Statement
The Waste Electrical and Electronic Equipment (WEEE) Regulations SI 2013 No 3113
and or the Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU
apply to all electrical and electronic equipment placed on the market in the UK and EU
covered by the scope of regulations which can be found in the Government Guidance
Notes (PDF) produced by the Department for Business Innovation and skills for the UK
and here for Europe.
All PEAK products that are subject to the WEEE directive are compliant with the
WEEE marking requirement. Such products are marked with the “crossed-out wheelie
bin” symbol (shown below) in accordance with European standard EN50419. All old
electrical equipment can be recycled. Please do not dispose of any electrical equipment
(including those marked with this symbol) in general rubbish bins. Please contact your
dealer or distributor for clarity.
Page 8
CSA Compliance Statement
CSA Group (Canadian Standards Authority) is a Nationally Recognised Testing
Laboratory (NRTL), headquartered in Toronto Canada.
They are authorised to evaluate product to both their own and Underwriters Laboratory
(UL) standards and certify the product to be in compliance to the relevant standards.
Peak products are certified to the current in force revision of the following standards
in order to cover both Canadian and United States requirements for “Safety
Requirements for Electrical Equipment for Measurement, Control and Laboratory use,
Part 1: general Requirements”.
Canada:
CAN/CSA C22.2 No 61010-1-12
United States:
UL 61010-1
As a result the products covered by this statement are certified and listed by CSA
accordingly and are entitled to carry the CSA mark with both Canadian and United
States subscripts , as shown below on the product rating label.
Page 9
EMC Class A Compliance Statements
European Union (EU) and United Kingdom (UK) Class A Compliance
statement
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
FCC Class A Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Industry Canada Class A emission compliance statement
This ISM device complies with Canadian ICES-001 (A).
Cet appareil ISM est conforme à la norme NMB-001 (A) du Canada.
Korea Communications Commission (KCC) statement
이 기기는 업무용(A급)으로 전자파적합기기로
서 판매자 또는 사용자는 이 점을 주의하시기
바라며, 가정외의 지역에서 사용하는 것을 목
적으로 합니다.
(This is electromagnetic wave compatibility equipment for business (Type A). Sellers
and users need to pay attention to it. This is for any areas other than home.)
Page 10
Technical Specification
Solaris XE
Environment
Solaris XE
Minimum Operating Ambient Temperature
Maximum Operating Ambient Temperature
Maximum Altitude
Maximum Relative Humidity
Minimum Storage Temperature*
Maximum Storage Temperature*
5°C (41°F)
35°C (95°F)
2000 m
80% Non-Condensing
-20°C (-4°F)
60°C (140°F)
Note: Please ensure that the generator is situated in a well ventilated environment.
Inlet Conditions
Inlet Air Pressure Min-Max
Min Air Inlet Flow (For Max Outlet Flow)
Minimum Air Inlet Quality
5.51 - 9.99 bar (80 - 145 psi) (125psi min to achieve
max output of 35L/min)
up to 100 L/min
ISO 8573-1:2010 Class[1.4.1]
Generator Outlets
Maximum Output Pressure
Maximum Outlet Flow Rate
Purity
Particles
Phthalates
Suspended Liquids
Gas Outlets
Start-Up Time For Purity
116 psi / 7.99 bar (variable)
up to 35 L/min
95-99.5% N2
<0.01µm
NONE
NONE
1
5 mins
Electrical Requirements
Voltage
Frequency
Current
Input Connection
Power Cord (Supplied)
Pollution Degree
Insulation Category
Fuses (UK Only)
100-230v
50/60 Hz
0.10A
C14 Plug
C13 Socket to Local Connection
2
II
13A BS1362
General
Dimensions cm (inches) WxDxH
Generator Weight Kg (lbs)
Shipping Weight Kg (lbs)
Max Weight Bearing Kg (lbs)
Page 11
34.3 x 65.5 x 15.6 (13.5 x 25.78 x 6.14)
15.1 (33.2)
18 (39.6)
100 (220)
Unpacking
Although Peak Scientific takes every precaution with safe transit and packaging, it is
advisable to fully inspect the unit for any sign of transit damage.
Check ‘SHOCKWATCH’ label for signs of rough handling prior to unpacking.
Any damage should be reported immediately to the carrier and Peak Scientific or the
Peak Partner from where the unit was purchased.
Follow the unpacking instructions posted on the side of the crate. It will require two
people to remove the unit from the shipping crate and to manoeuvre the generator onto
the bench.
Please save the product packaging for storage or future shipment of the generator.
Note: Included with the generator is a “Fittings Kit” containing mains power leads for
UK, EU, JP & US and also all the required fittings and warranty registration card. Be
careful not to discard these with the packaging.
Page 12
Fittings Kit Contents
Supplied in the Fittings Kit are all the fittings required to connect the generator to the
application. The contents of the Fittings Kit are as follows:
1. 6mm Teflon Tubing x 3m
2. ¼” - 6mm Push-Fit Elbow Fitting
x2
3. UK Mains Power Cable x 1
4. EU Mains Power Cable x 1
5. US Mains Power Cable 110v
x1
6. US Mains Power Cable 230v
x1
7. JP Mains Power Cable 100v
x1
8. 2.5mm Hex Key x 1
9. 3mm Hex Key x 1
10. No.8 Wall Plug x 4
11. No.8 Screw x 4
All of the generators output ports are located on the rear panel of the unit.
Unpacking Instructions
The unit weight constitutes a two person lift and as such, safe lifting practices should
be employed; do not attempt to lift on your own, as you will significantly increase the
chance of injury & damage to yourself and others around you.
1. Remove the generator from the packaging.
2. Next, with someone on either side of the unit, position your hands underneath the
unit ready to lift.
3. Ensuring your knees are bent and your back is straight, lift the unit to the desired
location.
Page 13
Installation
Generator Environment
The generator should be situated in a well ventilated environment and positioned such
that it can be easily disconnected if required. The generator is designed for indoor use
only. It should be installed adjacent to, underneath or in between the application(s) it
is supplying (maximum weight bearing up to 100kg) or it can be mounted onto a wall
horizontally; refer to installation guide for mounting details. If this is not convenient then
the unit can be sited elsewhere, however, consideration should be made of the lengths of
pipe runs as pressure drops can result from extended runs of pipe.
The performance of the generator (like all sophisticated equipment) is affected by
ambient conditions. Note should also be taken to the proximity of Air Conditioning
outlets. These can sometimes give rise to “pockets” of air with high relative humidity.
Operation of the unit within such a pocket could adversely affect its performance.
Consideration should also be given to the air flow around the unit. It is recommended
that an air gap of 75mm (3”) should be maintained down both sides and at the rear of
the unit. Please refer to the drawing on the next page for the general dimensions of the
unit.
Minimum Operating Ambient Temperature:
5 °C (41 °F)
Maximum Operating Ambient Temperature:
35 °C (95 °F)
Page 14
Generator Overview
Solaris XE General Dimensions
343 mm / 13.50”
655 mm / 25.78”
156 mm / 6.14"
Page 15
Horizontal postioning on wall.
Solaris XE Rear Connections
Power Switch
Power Inlet
Compressed Air Inlet
Nitrogen Outlet
CAUTION
Ensure outlets are connected to correct application. Connections
should only be carried out by trained personnel.
The Generator should be switched off prior to maintenance and
cleaning.
CAUTION
Page 16
Electrical Connection
Connect the generator to an appropriate 100-230 volt single-phase supply, refer to
the generator serial plate for input specification and ensure your supply matches the
requirements.
If the appropriate power cord is not supplied; a new plug, rated to at least 12 amps, can
be fitted by a qualified electrician. If a substitute mains supply cord is used, ensure that
it has an adequate rating. Failure to do so could cause damage to the generator.
WARNING
This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE
EARTHED. Before connecting the unit to the mains supply, please
check that your electrical supply falls within the specified range, see
below.
EARTH/GROUND (E):-
Green & Yellow
or
Green
LIVE (L):-
Brown
or
Black
Neutral (N):-
Blue
or
White
Electrical requirements are 100-230VAC nominal +/- 10% depending on chosen model.
However, running continuously at voltages outside this is not recommended. Extended
periods at extremes can have a detrimental effect on the operation and life of the
generator.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.
WARNING
Unit is fully pneumatic and can function without electricity.
If the unit is not connected to a power supply the pressure status indicator feature
will not be available and the LED lights will not function. The unit will perform all
other functions.
Page 17
Air Purity
The Solaris XE generator should be connected to an air supply that, as a minimum,
meets ISO8753-1:2010 Class 1.4.1
Class 1 Particulate
In each cubic metre of compressed air, the particulate count should not exceed 20,000
particles in the 0.1 - 0.5 micron size range, 400 particles in the 0.5 - 1 micron range and
10 particles in the 1 - 5 micron size range.
Class 4 Water
A pressure dew point (PDP) of +3°C or better is required and no liquid water is allowed.
Class 1 Oil
In each cubic metre of compressed air, not more than 0.01mg of oil is allowed. This is a
total level for liquid oil, oil aerosol and oil vapour.
Connecting to the application
Select the ¼”- 6mm push fitting from the fittings kit and connect to the generator AIR
IN and NITROGEN ports on the rear panel. Using suitable 6mm tubing, connect the
outlet of the generator to the inlet on the application.
Please refer to the Tubing Lengths section, to ensure correct tubing is being used.
CAUTION
Once the tubing is connected to the application, please ensure that it is
thoroughly checked for being leak-tight. Even the slightest leak in the
gas supply between the generator and the application can lead to a
reduction in efficiency.
Tubing Lengths
CAUTION
The diameter of the tubing which will be connected to the gas outlet is
important and is determined by the length of tubing required. Failure
to follow these recommendations could lead to pressure between
generator and application.
< 10 meters:
Use ¼”/3⁄16” (¼” O/D, 3⁄16” I/D) P.T.F.E. tubing.
> 10 - 40 meters: Use 3⁄8”/ 5⁄16” (3⁄8” O/D, 5⁄16” I/D). Tubing and fittings not supplied
in the fittings kit.
> 40 metres:
Please contact Peak Scientific with the relevant distance and
we will calculate the flow resistance and the tubing size required.
A combination of ¼”/3⁄16” and 3⁄8”/5⁄16” tubing may be used to ensure that there is no large
diameter tubing within the lab (i.e. for the first 20 meters from the generator use 3⁄8”/5⁄16”
and the final 10 meters to the application use ¼”/3⁄16” tubing). Keep the connections and
bends to a minimum.
Page 18
Start-Up Sequence
Connect the generator to the application as described in the installation guide. Switch
the generator on using the power switch on the rear panel of the unit and connect to the
air supply. Please note: Air can flow through the generator without the power switched
on, however the power must be switched on to give an indication of internal pressure in
the system.
The LED’s on the front panel will illuminate YELLOW.
YELLOW
Turn the air supply on. The fascia will illuminate GREEN when adequate system pressure
has reached 80psi. The Generator will provide Nitrogen almost instantaneously.
GREEN
The Generator will illuminate YELLOW if adequate internal pressure is not met or is lost
during operation. If the unit displays YELLOW during operation, disconnect the unit
from your appliance and check the input air supply to the generator.
Page 19
Setting the Output Pressure
The generator will deliver Nitrogen at the rated flow up to a maximum pressure of 116psi,
assuming an adequate air supply. The output pressure can be adjusted using the regulator at the front of the generator and viewed on the adjacent gauge.
To access the regulator, unclip the fascia from the unit.
Adjust the gauge to the required pressure. To ensure a smooth pressure profile, it is not
recommended to increase the output pressure to above the factory set 116psi.
If earth cable is removed from front fascia, ENSURE it is attached
before using the generator .
WARNING
Page 20
Service Requirements
Service Schedule
Purchase Interval
Component
Visit
12 months
Solaris Nitrogen XE Annual
Maintenance Kit
www.peakscientific.com/ordering
Please note: Only Peak Scientific approved components should be used.
Page 21
Qty.
1
Peak Protected
With Peak Scientific you invest in not only a product but peace of mind. With a network of
certified Peak engineers stationed throughout the globe, Peak’s rapid response team are
never far away and our commitment is to keep your generator running day in, day out,
protecting your laboratory workflow.
[Peak Protected] can provide…
Installation
A dedicated Peak engineer will visit
your lab to install and setup your
generator
IQ/OQ
Certified assurance for applications
requiring documented qualification
Complete plan
Swift response by a Peak Service
Engineer within 72 hours & planned
preventative maintenance
Spares
Genuine Peak parts with express
delivery, ensuring optimal
performance and lifetime
Premium Protected
Guaranteed rapid on-site response
within 24 hours & planned
preventative maintenance
Technical Support Hotline
Around the clock support by phone
or online with our global technical
helpdesk
To find out more about protecting your investment visit: www.peakscientific.com/protected
Page 22
Cleaning
Clean the outside of the generator only using warm soapy water and a clean damp
cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.
Cleaning should only be undertaken with the power switched off and
the power cord removed from the rear of the generator.
CAUTION
Under no circumstances should any solvents or abrasive cleaning
solutions be used as these can contain fumes that could be harmful to
the generator.
Care should be taken with Leak Detections Liquids.
CAUTION
Page 23
Troubleshooting
Problem
Possible Solution
•
Ensure power cord is plugged into the
generator and that the power socket is
turned on.
The generator will not switch on and the
power switch does not illuminate.
•
Check the fuse in the power cord plug.
•
Contact your service provider.
The fascia LED’s have not illuminated but the
power switch is illuminated.
•
Contact your service provider.
•
Check the air supply pressure to the
generator.
•
Contact your service provider.
•
Check for leaks between the generator and
instrument.
•
Contact your service provider.
The fascia Yellow illumination does not change
to green.
The instrument is reporting low pressure. The
fascia has turned from Green to Yellow
Page 24
Go Online or Complete and Return
We know that registering any of your recently purchased products is not the
first thing on your mind- but it is very important to both of us. Not all warranties
are alike and Peak Scientific stand out against other gas suppliers as we offer a
comprehensive, quick response, on-site warranty. This means that in the very
unlikely case that your gas generator develops a fault we have rapid support
teams on-hand around the world who are able to come to your lab and get you
back up and running in no time.
Register for your comprehensive 12 month on-site warranty with ease online at
www.peakscientific.com/protected.
Alternatively, you can send the completed form to Peak Scientific by post or
email at warranty@peakscientific.com.
Go Online or Complete and Return
You can register for your FREE 12 month Warranty with ease online at
www.peakscientific/protected.
Alternatively, you can send the completed form to Peak Scientific by post or
email at warranty@peakscientific.com.
Product Warranty Registration
Contact name
Email address
Company
Address
City/town
Postcode
Country
Telephone
Generator serial #
Model type
Installation date
Do you still use an
alternative gas solution i.e.
cylinders or bulk liquid?
Yes
What gas requirements do
you have in your lab?
Hydrogen
No
Nitrogen
Zero Air
Extend your cover with
Peak Scientific offer comprehensive gas generator after sales support packages.
Peak [Protected] aftercare support can guarantee an on-site response within 72
hours*, genuine parts from our ISO9001 approved factory and a 95% first-time fix
rate. See our enclosed Peak [Protected] leaflet for further information.
Important!
You have 1 month to register your Peak Scientific product from the date of installation. Once registered
the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your
generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com.
For generators that remain unregistered after 1 month from the shipment date, the warranty will be
considered active from the date of factory dispatch.
* Complete Plan only
Important!
You have 1 month to register your Peak Scientific product from the date of
installation. Once registered the warranty will be honoured for a period of 12
months. If you wish to defer the installation of your generator, you must notify
Peak Scientific immediately by emailing warranty@peakscientific.com. For
generators that remain unregistered after 1 month from the shipment date, the
warranty will be considered active from the date of factory dispatch.
Page 25
Supported Maintenance Plan
Introduction
The following is a guide for maintenance of the Solaris XE Nitrogen Generator as provided for by the Peak Service Plan.
This procedure is to be performed on an annual basis
1. Check that the instrument is not in use and that it is OK to disconnect the Gas
Supply. Check that the Gas Demand is turned OFF.
2. Stop the Air Supply and turn the Generator OFF.
3. Remove the fascia panel and disconnect the earth tab.
4. Remove the two top bolts of the filter tray. Confirm that the gauge has returned to
Zero. Any pressure gauge that does not return to zero may be damaged and must
be replaced.
Page 26
5. Remove the LED Molex connection. Once disconnected, open the filter tray using the
tab.
Stage 1 filtration – 0.01μm Particulate
6. Remove the four bolts on the top of the filter using the 3mm hex key.
Page 27
7. Remove the bowl from the filter assembly and replace the filter element 3300675.
Reverse steps 6 and 7 to reassemble.
Stage 2 filtration – Active Carbon
8. Remove four bolts on the top of the filter using the 3mm hex key.
9. Remove the bowl from the filter assembly and replace the filter element 3300676.
Reverse steps 8 and 9 to reassemble.
Page 28
10. Return the filter tray to the upright position and reattach the two mounting bolts.
11. Attach the LED Molex connection.
12. Attach the fascia to the generator. ENSURE EARTH TAB IS RE-ATTACHED.
Page 29
13. Start the air supply and turn the Generator ON.
14. Switch the Instrument gas demand ON.
Service Parts List
Service parts Solaris 25 & Solaris 35
Service
Component
Part No.
Qty.
12 months
Element, filter 0.01 μm
3300675
1
12 months
Element, filter active carbon
3300676
1
As an alternative to purchasing the 12 month service items individually an Annual
Service Kit is available as one part number. This contains all the filters required for this
Generator and offers a costs saving over buying the components separately.
Purchase interval
12 months
Page 30
Component
Solaris25_35 Annual Service Kit
Part No.
3301048
Qty.
1
Page 31
Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries
across every continent around the world. This allows us to provide an industry-leading rapid response
service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top
priority.
To discuss Peak Protected generator cover and payment options speak to your local Peak
Representative or for further information contact: protected@peakscientific.com
Peak Scientific
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Tel: +44 141 812 8100
Fax: +44 141 812 8200
For further information on any of our
generator products please contact
marketing@peakscientific.com
Copyright © Peak Scientific Instruments Ltd 2024 — Solaris XE User Manual Rev 9 RSID 2302 EN —25/06/2024