Genius XE (All Models)
User Manual

Copyright © Peak Scientific Instruments Ltd 2018 — GeniusXE User Manual Rev 2 RSID 2299 EN —18/07/2018

Register Product to Operate
To begin operation you will need to register your generator. You can do so by
visiting www.peakscientific.com/activate or by downloading the Peak Genius
App.
Registering will activate your 2 year warranty* - covering every single
component in your generator.






Important!
You must register your generator before nitrogen generation can commence. In
order to be eligible for warranty your generator must be registered to the end
user (not a reseller or distributor) and must have a paid annual preventative
maintenance arranged within 12 months of the installation date & carried out by
a Peak approved Field Service Engineer. Once registered the warranty will be
honoured for a period of 24 months.*
* Call out and labour charges may apply where generator was not purchased directly from Peak

Page 2

Contents
Change History

4

How to use this Manual

4

Warranties and Liabilities

5

Safety Notices

7

Declaration of Conformity

8

Environmental Declaration

9

Unpacking 11
Fittings Kit Contents

12

Installation 13
Operation in High Ambient Temperatures

13

Generator Overview

14

Drain Connection

16

Electrical Connection

17

Start-Up Sequence

18

Product Registration

19

Connecting to the application

21

Normal Operation

23

Eco Mode

23

Service Screens

24

Error Screens

25

Information Screens

26

Settings Screens

27

Service Log-in Sceen

27

Unusual Operation

27

Service Requirements

28

Service Schedule

28

Service Indication

29

Peak Protected

30

Cleaning

31

Alarm Messages

32

Troubleshooting 33

Page 3

Change History
Rev

Comment

Name

Date

1

Initial Release

Liam Couttie

25/04/2018

2

Fittings Kit Update

Liam Couttie

18/07/2018

How to use this Manual
This manual is intended for end users and has been written as a reference document
where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, should you
require any further assistance or support please do not hesitate to contact Peak Scientific or the Peak Partner from which you purchased your generator.

Page 4

Warranties and Liabilities
Warranty & Liability Coverage
1. Peak warrants that, subject to the provisions in this statement, purchased Peak generators, whether
purchased directly from Peak or indirectly via an approved, certified and trained distributor or partner
(referred to hereafter as a “Peak Partner”) will comply in all material respects with any specifications
referred to in your customer order confirmation and, subject to installation and operational guidelines
being followed as described in applicable product manuals, shall be free from any defects in quality
of materials or workmanship for a period of one year from the date of installation, provided this takes
place within 3 months of factory dispatch.
2. Where the purchased generator is from the Precision Hydrogen series, Peak further warrants that,
subject to installation and operational guidelines being followed as described in applicable product
manuals, the hydrogen cell shall be free from any defects in quality of materials or workmanship for a
total period of three years (inclusive of warranty period specified in clause 1) from date of installation,
provided this takes place within 3 months of factory dispatch.
3. Where the purchased generator is from the i-Flow 6000 series, Peak further warrants that, subject
to installation and operational guidelines being followed as described in applicable product manuals,
the generator shall be free from any defects in quality of materials or workmanship for a total period
of two years (inclusive of warranty period specified in clause 1) from the date of installation, provided
this takes place within 3 months of factory dispatch and the following provisions have also been met:
a. you must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on
or before the end of the first 12 months of your ownership, and serviced at least once during each
subsequent 12 month period thereafter;
b. the generator (and any associated equipment) must have been commissioned by Peak or a Peak
Partner;
c. the feed air or inlet air supply to the generator must comply with ISO 8573-1:2010 Class 1.2.1 at all
times;
d. your air compressor, dryer, filtration and oil removal systems must be deemed suitable for use by
Peak or a Peak Partner, and must be changed and serviced regularly, in line with the equipment manufacturer’s recommended guidelines; and
e. any generator failure or fault that is deemed to have been caused by the failure of any upstream
equipment, component, part or system (such as air compressor, air treatment or filtration) will be
excluded from the warranty described herein.
4. Where the purchased generator is from the Genius XE range, Peak further warrants that, subject to
installation and operational guidelines being followed as described in applicable product manuals, the
generator shall be free from any defects in quality of materials or workmanship for a total period of
two years (inclusive of warranty period specified in clause 1) from the date of registration, provided
the following provisions have also been met:
a. The product must be registered within 12 months of the build date, to the end user (registrations to
3rd party resellers or other channel partners will not qualify for the warranty extension).
b. You must purchase a service plan, ensuring the generator is serviced by Peak or a Peak Partner on
or before the end of the first 13 months of your ownership
c. The product is required to be serviced in accordance with manufacturer requirements, preventative
maintenance visit must be arranged within 13 months of installation, and the generator must be serviced by Peak, or a Peak Partner within 13 months of installation.
d. Products purchased via Peak Partners may be subject to call-out and labor charges, which is at the
discretion of the Peak Partner.
5. Peak also warrants that any replacement parts whether purchased (directly from Peak, or via a Peak
Partner) or supplied as part of any remedial action undertaken in line with the provisions of clauses 13
and 14, shall be free from any defects in quality of materials or workmanship for a period of 180 days
from the date of factory dispatch, provided its installation is performed by Peak or a Peak Partner.
6. This warranty does not exclude Peak’s liability in respect of any claim for death or personal injury to

Page 5

any person, in so far as such can be attributed to negligence or breach of duty of care directly resulting
from failure of Peak to comply with the provisions in clauses 1, 2, 3, 4 & 5.

Exclusions & Limitations
7. This warranty does not cover:
a. damage, deterioration or malfunction resulting from an alteration or modification to a generator
which has not been carried out by Peak or a Peak Partner;
b. damage, deterioration or malfunction resulting from what Peak reasonably believes to be abuse, or
misuse of a generator by you or any third party;
c. liability for accident or neglect (other than pursuant to clause 6);
d. maintenance or repairs which have not been carried out by Peak or a Peak Partner;
e. operation of a generator or exposure of a generator to environmental conditions that fall out-with
operational guidelines as specified in the applicable product user manual; and
f. lightning, power surges or any other acts of God or nature.
8. This warranty is non-transferrable. Only the original owner of the generator may benefit from the
terms within this statement.
9. Peak shall not be liable in respect of any claim made for costs, damages, losses or expenses (whether consequential, direct, indirect or otherwise) or in any respect howsoever arising including, but not
limited to, liability from accident or negligence (other than pursuant to clause 6) that may be suffered
by you or any third party.
10. No person or entity is authorised to change the terms and conditions outlined in this warranty statement in any respect, or to create any additional obligations or liabilities for any party involved.
11. This warranty statement supersedes any and all prior warranty agreements between the parties and
constitutes the complete, final and exclusive understanding of the parties with respect to the subject
matter. All prior negotiations, representations, or promises, whether oral or written, of either party
shall be deemed to have been merged herein.
12. If any part of this warranty statement is invalidated, for whatever reason, such part will be deleted
and the rest shall remain unaffected, continuing to be in full force and effect.

Delivery of Warranty Service
13. Subject to clause 14, and:
a. Peak being notified by you, within the duration of the applicable warranty period, of any defect
that you think is subject to any warranty valid under clauses 1, 2, 3, 4 or 5; and
b. Peak being permitted to inspect the generators, parts and their installation (along with any relevant
packaging)
Peak shall at its option repair or replace defective generators or parts (including, if necessary, any
moving parts and irrespective of runtime). No additional charges will apply, for parts or delivery and,
where applicable, labour or travel. Peak will endeavour to deliver this service within 3 working days of
your notification.
14. Where, in Peak’s reasonable opinion, a defect is subject to an exclusion described in clause 7, Peak
reserves the right to charge for parts or delivery and, where applicable, you may also be charged by
Peak for call out, labour or travel in respect of any repair or replacement which you authorize Peak to
carry out.

Page 6

Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this manual refer to the most
likely potential hazards, but by definition cannot be all inclusive. If the user employs an
operating procedure, item of equipment or a method of working which is not specifically recommended by Peak Scientific, the user must ensure that the equipment will not
be damaged or become hazardous to persons or property.

Symbols
This manual uses the following symbols to highlight specific areas important to the safe
and proper use of the generator.

WARNING

CAUTION

A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.
A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the generator or the application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed
before proceeding.

Safety Notice to Users

WARNING

WARNING

These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.

WARNING

Page 7

Declaration of Conformity
We

Peak Scientific Instruments Ltd.

Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:
Equipment: Nitrogen Generator


Models:

Genius XE 35 & 70


To which this declaration relates, is in conformity with the applicable EC directives,
harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Electrical Equipment for measurement, control and laboratory use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for measurement, control and laboratory use.
• FCC47 CFR Part 15 Class B
Unintentional radiators; Conducted and Radiated emissions limits.

Year CE mark first applied: 2017
All evaluation, testing and certification issued by:
Nemko Canada
York EMC Services
303 River Road, Ottawa,
Unit 1, Grangemouth Technology Park,
Ontario, Canada,
Earls Road, Grangemouth, Scotland,
K1V 1H2 FK3 8UZ
Signed: Name: Chris Pugh
Date:

Page 8

2/11/2017

Position:

Chief Technology Officer

Environmental Declaration
We

Peak Scientific Instruments Ltd.

Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:
Equipment: Nitrogen Generator


Models:

Genius XE 35 & 70

Is fully compliant with the following Directives
• 2012/19/EU

WEEE (Waste of Electrical and Electronic Equipment)

• 2011/65/EU

RoHS 2 (Restriction of Hazardous Substance)

Peak Scientific Instruments Ltd fully complies with its obligations towards the European
WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These
obligations are being met within the B2B compliance group.
Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to
ensure that our products comply with the principles and requirements of the European
recast RoHS (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar
directives in the United States and China, for example, have also been captured within
this program.
Where a specific certificate of compliance is required, this can be requested, on
a product serial number basis, directly from Peak Scientific Instruments Ltd, by
contacting us through our website on www.peakscientific.com
Signed: Name: Chris Pugh
Date:

Page 9

2/11/2017

Position:

Chief Technology Officer

Technical Specification
Environment
XE 35
Minimum Operating Ambient Temperature
Maximum Operating Ambient Temperature
Maximum Altitude
Maximum Relative Humidity
Minimum Storage Temperature*
Maximum Storage Temperature*

CXE 70
5°C / 41°F
35°C / 95°F
2000m
80% @ 35°C
-20°C / -4°F
60°C / 140°F

Generator Outlets
Max Gas Outlet Pressure
Max Gas Outlet Flow Rate†
Purity
Particles
Phthalates
Suspended Liquids
Hydrocarbon Removal
Gas Outlets
Drain Outlet
Pressure Gauges/Displays
Start-Up Time

116 psi / 8 bar
35 L/min

70 L/min
Up to 99.5%
None
None
1 x ¼" BSPP
1 x ¼" BSPP
2
30 mins

Electrical Requirements
Voltage
Frequency
Current
Input Connection
Power Cord (Supplied)
Circuit Breakers
Pollution Degree
Insulation Category
Transient Over Voltages

120V±5% / 230V±10%
230V±10%
120V 60 Hz / 230V 50/60Hz
230V 50/60Hz
12 A @ 120V / 8 A @ 230V
12 A @ 230V
C20 Plug
C19 Socket
230V 6A MCB, 2A MCB
120V 10A MCB, 2A MCB
2
Class 1
Over Voltage Category II

General
Dimensions cm (inches) WxDxH
Generator Weight Kg (lbs)
Shipping Weight Kg (lbs)
Noise Level‡

57(22.4) x 71(27.9) x 64(25.1)
92 Kg (202.8 lbs)
129 Kg (284.3 lbs)
55.5 dBA

57(22.4) x 71(27.9) x 100(39.3)
147 Kg (324 lbs)
182.5 Kg (402.3 lbs)
59.3 dBA

* Note: Please ensure Generator is situated in a well ventilated environment.


Note: Flows in LPM are expressed as normalised volumes at 101.3 kPa, 20°C



Note: Noise level expressed as SPL (Sound Pressure Level) measured at 1m from source in a reverberant chamber in accordance
with ISO 3741:2010.

Page 10

Unpacking
Although Peak Scientific takes every precaution with safe transit and packaging, it is
advisable to fully inspect the unit for any sign of transit damage.
Check ‘SHOCKWATCH’ and ‘TIP-N-TELL’ labels for signs of rough handling prior to unpacking.

Any damage should be reported immediately to the carrier and Peak Scientific or the
Peak Partner from where the unit was purchased.
Follow the unpacking instruction supplied with the generator. It will require two people
to remove the unit from the shipping crate and to manoeuvre the generator to the
desired location.
Please save the product packaging for storage or future shipment of the generator.
Note: Included with the generator is a “Fittings Kit” containing mains power leads for
UK, EU & US and also all the required fittings and warranty registration card. Be careful
not to discard these with the packaging. 

Page 11

Fittings Kit Contents
Supplied in the Fittings Kit are all the fittings required to connect the generator to the
application. The contents of the Fittings Kit are as follows:

Genius XE 35 (120V)
1. 1/4" x 1/4" Compression Fitting

x1

2. 1/4” x 6mm Push-Fit Fitting

x2

3. Flow Control Silencer

x 1

4. 1/4” PTFE Tubing x 3m
5. 6mm PTFE Tubing x 3m
6. 6mm Polyethylene Tubing x 3m
7. 4mm Hex Key x 1
8. US 120V Mains Power Cable

x1

9. Genius XE Installation Guide

x1

Genius XE 35 & XE 70 (230V)
1. 1/4" x 1/4" Compression Fitting*

x1

2. 1/4” x 6mm Push-Fit Fitting**

x2

3. Flow Control Silencer

x 1

4. 1/4” PTFE Tubing* x 3m
5. 6mm PTFE Tubing* x 3m
6. 6mm Polyethylene Tubing x 3m
7. 4mm Hex Key x 1
8. UK Mains Power Cable x 1
9. EU Mains Power Cable x 1
10. US 230V Mains Power Cable

x1

11. Genius XE Installation Guide

x1

12. 1/4" Tee Fitting*** x 1
*

x2 in XE 70 Fittings Kit

**

x3 in XE 70 Fittings Kit

***

XE 70 Fittings Kit Only

All generator output ports are located on the output panel at the rear of the unit.

Page 12

Installation
Generator Environment
The generator is designed for indoor use only. It should be installed adjacent to
the application(s) it is supplying. If this is not convenient then the unit can be sited
elsewhere. Consideration should be made of the lengths of pipe runs as pressure drops
can result from extended runs of pipe. See page 21 for guidance on tubing lengths
greater than 3m.
Performance of the generator is affected by ambient conditions. Note should also be
taken to the proximity of Air Conditioning outlets. These can sometimes give rise to
“pockets” of air with high relative humidity. Operation of the unit within such a pocket
could adversely affect its performance. Consideration should also be given to the air
flow around the unit. An air gap of 75mm (3”) should be maintained down both sides
and 100mm (4") at the rear of the unit. Please refer to the drawing opposite for the
general dimensions of the unit.
Please ensure generator is situated in a well ventilated environment and is positioned to
permit easy diconnection if required.
Minimum Operating Ambient Temperature:

5 °C (41 °F)

Maximum Operating Ambient Temperature:

35 °C (95 °F)

Operation in High Ambient Temperatures
Genius XE generators are designed to supply the rated flow, purity, and pressure in
most laboratory environments, however high ambient temperatures can affect the
performance of the generator. Output flow capabilities may be restricted in high
ambient temperatures, or areas with insufficient air circulation.

Page 13

Generator Overview
General Dimensions
Genius XE 35
570 mm / 22.4”

710 mm / 27.9”

640 mm / 25.1"

Genius XE 70
570 mm / 22.4”

710 mm / 27.9”

1000 mm / 39.3"

The generator must always be placed on a flat, level surface. Failure to
do so will affect the performance of the generator.
WARNING

Page 14

Rear Connections
Power Socket
Nitrogen Port
Drain Port

Ensure outlets are connected to correct applications.
WARNING

Connections should only be carried out by trained personnel
WARNING

Unit Controls
Touch Screen

Page 15

Drain Connection
Fit the 6mm push fit fitting to the drain port at the rear of the unit.
Tighten using a 16mm or 5/8” spanner. Use the 6mm tubing to connect this to a suitable
drain connection or container. It should be noted that the generator can expel a
considerable amount of water (dependant on ambient humidity).

CAUTION

Page 16

If a container is used it should be emptied at regular intervals. The
container must NOT have an air tight seal as water and air are expelled
at pressure. Fix the drain ending of the tube firmly to prevent it from
vibrating during draining.

Electrical Connection
Connect the generator to an appropriate 120 or 230 volt single-phase supply, refer to
the generator serial plate for input specification and ensure your supply matches the
requirements.
If the appropriate power cord is not supplied; a new plug, rated to at least 12 amps, can
be fitted by a qualified electrician.
If a substitute mains supply cord is used, ensure that it has adequate rating. Failure to
do so could cause a fire risk.

WARNING

This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE
EARTHED. Before connecting the unit to the mains supply, please
check the information on the serial plate. The mains supply must be of
the stated AC voltage and frequency.

EARTH/GROUND (E):-

Green & Yellow or

Green

LIVE (L):-

Brown

or

Black

Neutral (N):-

Blue

or

White



Electrical requirements are 120VAC nominal +/- 5% or 230VAC nominal +/- 10%
depending on chosen model. Extended periods at extremes can have a detrimental
effect on the operation and life of the generator.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.
WARNING

The supply voltage will be displayed on the touch screen when the generator is
switched on. If the reading is 219V or less, then we would highly recommend fitting
a Dual Tap Transformer 06-3200 (XE 35) or 06-3210 (XE 70). These can be ordered
directly from Peak Scientific.
For Genius XE 35 (120V) voltage should not be less than 114V.

Page 17

Start-Up Sequence

CAUTION

Before the generator is connected to the application, the generator
should be operated in isolation (i.e. not connected to the application)
for thirty minutes. This is to ensure any impurities present are purged
from the system. Failure to do this may harm the application.

Before connecting the generator to the mains and switching it on for the purge run, it is
necessary to fit the silencer to the nitrogen output port
Once this is done, the generator can be connected to the mains and switched on.
The Genius XE will then go through Product Registration. This is detailed on the next
page.
Continue to operate the generator for a further 30 minutes to allow all the internal pipework and storage tanks will have been purged with Nitrogen.
The generator is now purged, the silencers can be removed and the tubes can be
connected at the rear of the unit.

Page 18

Product Registration
Before the generator will start-up for the first time the user must enter a unique 4-digit
PIN code.
To receive your generator’s unique PIN code, please register on the Peak website www.
peakscientific.com/activate or download the Peak mobile app from the Google Play
Store or Apple App Store. A PIN code may also be requested by phoning the Peak
helpdesk.
This code is only required on the initial start-up of the unit.
1. Press the 'I've got my pin' button on the screen on the front of the generator.

REGISTER YOU GENERATOR WITH OUR APP
OR VISIT WWW.PEAKSCIENTIFIC.COM/ACTIVATE
SERIAL: [ XXXXXXXXXXXX ]

I’ve got my pin

2. Enter your PIN.






Serial: 999999999 UTC: 24:24



[Passcode: XXXX]

1

2

3

4

5

6

7

8

9

Cancel

0

3. The unit will then go through initialisation.

[Initialisation...]
Model : GENIUS XE 35
Software : v0.00
Voltage : 230V RMS

Initialisation Time : 00:00

Page 19

Continue...

4. Upon completion of the initialisation phase, the screen will display the below, home
screen.



GENIUS XE 35



Nitrogen:
XXXX psi




Page 20

S/N: XXXXXXXXXXXX



Connecting to the application
Once the initial purge run of 30 minutes has completed, it is ready to be connected to
the application(s).

CAUTION

The pressure in the internal storage tanks must be allowed to dissipate
before connecting the generator to the application(s). This may be
done by leaving the Nitrogen port at the rear of the generator open
and turning off the power supply to the generator.

Select the appropriate 1/4" or 6mm fitting from the fittings kit and connect to the
generator outlet. Using the appropriate tubing, connect the outlet of the generator to
the inlet on the application.
If you require more tubing than is supplied please refer to the Tubing Lengths section.

CAUTION

Once the tubing is connected to the application, please ensure that it
is thoroughly checked for being leak-tight. Even the slightest leak in
the gas supply between the generator and the application can lead to
a drop in Nitrogen purity or insufficient pressure.

Tubing Lengths

CAUTION



The diameter of the tubing which will be connected to the gas outlet is
important and is determined by the length of tubing required. Failure
to follow these recommendations could lead could lead to excessive
pressure drops between generator and application.



> 3-10 meters:


Use 6mm OD / 4mm ID or 1/4” OD / 3/16” ID PTFE tubing.
Use 8mm OD / 6mm ID or 5/16” OD / 1/4” ID PTFE tubing.
Tubing and fittings not supplied in the fittings kit.

> 10 - 40 meters: Use 10mm OD / 8mm ID or 3/8” OD / 5/16” ID PTFE tubing.

Tubing and fittings not supplied in the fittings kit.

> 40 metres:


Page 21

Please contact Peak Scientific with the relevant distance and
we will calculate the flow resistance and the tubing size required.

Setting the Output Pressure
The output pressure is factory set to 100psi, however; the generator will deliver
Nitrogen at the rated flow up to a maximum pressure of 116psi. The output pressure can
be adjusted using the pressure regulator at the rear of the generator and viewed on the
adjacent gauge.
To ensure a smooth pressure profile, it is not recommended to increase the output
pressure above 116 psi.
The pressure gauge in the rear is for indication only and may differ from the reading on
the touch screen.

Pull to Unlock
Push to Lock

Page 22

Normal Operation
Genius XE generators require minimal operator input. So long as the generator is
installed as described in earlier sections and is serviced in accordance with the
specified maintenance recommendations (see Service Requirements), then it will
operate in accordance with the demands of connected applications.
The generator will automatically produce the factory set pressure as detailed in the
technical Specifications. The outlet flow rate will vary to satisfy customer demand up
to a maximum flow rate in normal operating conditions of 35 LPM (Genius XE 35) or 70
LPM (Genius XE 70).
Genius XE generators are variable-purity systems, and will supply a higher purity of
nitrogen at lower flow rates, with a minimum purity of 95% nitrogen at the maximum
rated output flow.





GENIUS XE 35



Nitrogen:
XXXX psi







Home Screen
This is the main home screen in normal operation.




S/N: XXXXXXXXXXXX

Idle Screen

N2

The Idle Screen is displayed if no system changes occur
within a 20 Min period, is not running in Eco mode or
screen is not touched.
The screen is removed if the system changes or the
screen is touched and returns to the relevant home
screen.

Eco Mode
To reduce energy consumption and minimise component wear, Genius XE generators
feature a smart “Eco-Mode” which ensures gas is produced as is necessary to satisfy
demand.
When demand from the instrument stops the Genius XE generator will stop. If demand
from the application starts again, the system will detect the demand for gas and will
automatically restart. Additionally, if the flow demand from the generator is below its
maximum capacity, the generator will reduce the number of running compressors to
the minimum required.

Page 23




  




GENIUS XE 35



Nitrogen:
XXXX psi

Eco Mode Home Screen
This is the main home screen in Eco Mode.




S/N: XXXXXXXXXXXX

Eco Mode Idle Screen
The Eco Mode Idle Screen is displayed if no system
changes occur within a 20 Min period or screen is not
touched.
The screen is removed if the system changes or the
screen is touched and returns to the relevant home
screen.

ECO MODE

Service Screens 



GENIUS XE 35










Nitrogen:
XXXX psi

This is the main home screen when a service is due
displaying a yellow service warning.
The screen will alternate between the home screen and
a full screen warning as shown next.




Service Due Home Screen Warning

S/N: XXXXXXXXXXXX

Service Due Warning Screen



This is the full screen warning when service is due.
The Confirm button returns the user to the home
screen.

Confirm
SERVICE DUE
CONTACT YOU LOCAL SERVICE REPRESENTATIVE
OR VISIT WWW.PEAKSCIENTIFIC.COM
SERIAL: [ XXXXXXXXXXXX ]





Page 24




GENIUS XE 35 
Nitrogen:
XXXX psi

Service overdue : XX/XX/XXXX
S/N: XXXXXXXXXXXX





Service Overdue Home Screen Warning
This is the main home screen when a service is overdue
displaying a red service warning.
The screen shows the date on which the service was due.
The screen will alternate between the home screen and a
full screen warning as shown next.

Service Overdue Warning Screen





This is the full screen warning when service is overdue.
The Confirm button returns the user to the home
screen.

Confirm
SERVICE OVERDUE
CONTACT YOU LOCAL SERVICE REPRESENTATIVE
OR VISIT WWW.PEAKSCIENTIFIC.COM
SERIAL: [ XXXXXXXXXXXX ]

Error Screens






GENIUS XE 35









Nitrogen:
XXXX psi




Minor Error Home Screen
This is the main home screen when there is a minor
error, displaying a yellow error warning and the error
code.
The screen will alternate between the home screen and
a full screen warning as shown next.

[REF CODE: XXXX]
S/N: XXXXXXXXXXXX

Minor Error Warning Screen



This is the full screen warning when a minor error has
occured.
The Confirm button returns the user to the home
screen.

Confirm
[REF CODE: XXXXXXXXXX]
OR VISIT WWW.PEAKSCIENTIFIC.COM
SERIAL: [ XXXXXXXXXXXX ] 






GENIUS XE 35



Nitrogen:
XXXX psi








Major Error Home Screen
This is the main home screen when there is a major
error, displaying a red error warning and the error code.
The screen will alternate between the home screen and
a full screen warning as shown next.

[REF CODE: XXXX]
S/N: XXXXXXXXXXXX

Major Error Warning Screen


Confirm
[REF CODE: XXXXXXXXXX]
OR VISIT WWW.PEAKSCIENTIFIC.COM
SERIAL: [ XXXXXXXXXXXX ]

Page 25

This is the full screen warning when a major error has
occured.
The Confirm button returns the user to the home
screen.



Information Screens





[System Info]
System



XXXXX hrs

Comp 2

XXXXX hrs

Comp 3

XXXXX hrs

Comp 4

XXXXX hrs








Date
XX/XX/XX

XXXX
XXXX

XX/XX/XX

XXXX

XX/XX/XX



XXXX












[Temp/Hum]
°C

100

80

90

70

60
50

30

40

20

30

10



-10

10

xx/xx

xx/xx

xx/xx

[Temp] 

xx/xx

xx/xx

[Hum] 

xx/xx

xx/xx






0





[Flow Rate]

Y-axis:

80
70
50



30
20
0

xx/xx

xx/xx

xx/xx

xx/xx

xx/xx

xx/xx

xx/xx






[Nitrogen] 





[Pressure]
90

Y-axis:

80
70
60



50
30
20

Page 26

0

Gas Pressure (selected Unit)

X-axis:
Time, 7 day rolling dates day/month
displayed

40

10



Pressure Graph
1 result plotted: Nitrogen

Psi

100



Gas Flow (selected Unit)

X-axis:
Time, 7 day rolling dates day/month
displayed

40

10



Flow Rate Graph

90

60



X-axis:
Time, 7 day rolling dates day/month
displayed

1 results plotted: Nitrogen

l/min
100



Right: Humidity (%)

20

0



Left: Temp (selected Unit)



70

40

Y-axis:

80

60
50



Temperature Graph
2 results plotted: Temperature & Humidity

%

90



System Error Screen
Displays System Errors in an up down navigation scroll.

Ref code

XX/XX/XX







[System Errors]



System Info Screen
Displays System Info in an up down navigation scroll.

Value

Comp 1







xx/xx

xx/xx

xx/xx

[Nitrogen] 

xx/xx

xx/xx

xx/xx

xx/xx

Settings Screens




Select Flow Unit Screen
[Select Flow Unit]

Allows the user to select a unit of Flow.

l/min
l/hour
m3/min



m3/hour





Select Pressure Unit Screen
[Select Pressure Unit]

Allows the user to select a unit of Pressure.

bar
atm
kPa






Select Temperature Unit Screen
[Select Temp Unit]

Allows the user to select a unit of Temperature.

°F
°C



Service Log-in Screen






Serial: 999999999 UTC: 24:24

[Passcode: XXXX]

1

2

3

4

5
8

Allows the Peak Approved Engineer access to the
Genius XE's service menus.

9

Cancel

Service Log-in Screen

6

7



0

Unusual Operation
If at any time the generator begins to emit excessive noise or vibration, then it should
be switched off and you should contact Peak Scientific or the Peak Partner from which
the generator has been purchased
Page 27

Service Requirements
Service Schedule
Purchase Interval
12 Months

Component

Qty.

Genius XE 35 120/230V
Annual Maintenance Kit

1

Genius XE 70 230V
Annual Maintenance Kit

1

Genius XE 35 120V 48 Month Kit
48 Months

Visit

www.peakscientific.com/ordering

1
1

Genius XE 70 230V 48 Month Kit

Page 28

Genius XE 35 230V 48 Month Kit

1

Service Indication
The generator will notify the user of the service interval for the internal compressors.
The generator has the following Service Indication Stages:-

Stage 1 
12 months after installation, the service indicator will show on the display along with a
warning message.
This is to make the user aware that a service of the generator is due and should be
planned at the earliest convenience. The generator will continue to operate as normal
with the service indicator on. If the warning message has been acknowledged, the icon
will still be displayed in the corner of the HMI; pressing the icon will show the message
again.

Stage 2 
If the service is not completed the generator will continue to run. After 2 weeks, the
service overdue indicator will show on the HMI along with a warning message.
This is to make the user aware that the service of the generator is now overdue and
must be completed immediately to ensure the continuous trouble free operation of
the generator. If the warning message has been acknowledged, the icon will still be
displayed in the corner of the HMI; pressing the icon will show the message again.

Service Indication Reset
Once the service has been completed the Service Indication can be reset through the
service interface. This will be performed by the Peak Service Engineer or trained service
representative that completes the service operation.

Page 29

Peak Protected
With Peak Scientific you invest in not only a product but peace of mind. With a network of
certified Peak engineers stationed throughout the globe, Peak’s rapid response team are
never far away and our commitment is to keep your generator running day in, day out,
protecting your laboratory workflow.

[Peak Protected] can provide…

Installation

A dedicated Peak engineer will visit
your lab to install and setup your
generator

IQ/OQ

Certified assurance for applications
requiring documented qualification

Complete plan

Swift response by a Peak Service
Engineer within 72 hours & planned
preventative maintenance

Spares

Genuine Peak parts with express
delivery, ensuring optimal
performance and lifetime

Premium Protected

Guaranteed rapid on-site response
within 24 hours & planned
preventative maintenance

Technical Support Hotline

Around the clock support by phone
or online with our global technical
helpdesk

To find out more about protecting your investment visit: www.peakscientific.com/protected

Page 30

Cleaning
Clean the outside of the generator only using warm soapy water and a clean damp
cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.
Cleaning should only be undertaken with the power switched off and
the power cord removed from the rear of the generator.

CAUTION

CAUTION

Page 31

Under no circumstances should any solvents or abrasive cleaning
solutions be used as these can contain fumes that could be harmful to
the generator.
Care should be taken with Leak Detection Liquids.

Alarm Messages
In the event of an alarm condition a message will be displayed on the user interface
with a descriptive message and error code.
Please note the displayed error code and contact your service provider.
Minor Alarm Message 
There is an issue with the generator but it will continue to supply gas at the required
pressure, flow and purity.
Major Alarm Message 
There is a problem with the generator that may prevent it from supplying gas at the
required pressure, flow or purity. In some instances the generator will automatically shut
down to prevent further damage.

Page 32

Troubleshooting
Problem

Possible Solution
• Ensure power cable is plugged into the
generator and that the power socket is
turned on.

The generator will not switch on and the
power switch does not illuminate.

Compressors are running but pressure is not
building.

• Check the fuse in the power cable plug (if
fitted).
• Contact your service provider.

• Ensure that the generator is connected to
your application and is leak free.
• If carrying out the purge run make sure
that the flow control silencer is fitted.
• Contact your service provider.
• Check pressure readings on the display are
showing normal pressure.

The application is reporting low pressure.

• Ensure that the generator is connected to
the application and leak free
• Contact your service provider.

Service indicator on the screen is active



• The generator is due for service. Contact
your service provider.
• Refer to Service Indication section of this
manual for further information.
• The generator is overdue for service.

Overdue service indicator on the screen is
active





• Contact your service provider urgently.
• Refer to Service Indication section of this
manual for further information.
• Ensure ambient temperature and humidity
is within specification.

Generator displays a minor error code



• Ensure there are no leaks between the
Generator and the mass spec.
• Ensure there is an adequate ventilation
gap around the back and sides of the
generator.
• Contact your service provider.

Generator displays a major error code



• Ensure there is a complete, leak tight
connection between the generator and the
application
• Ensure the flow demand on the generator
is within rated limits.
• Contact your service provider.

Page 33

Notes

Page 34

Notes

Page 35

Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries
across every continent around the world. This allows us to provide an industry-leading rapid response
service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top
priority.
To discuss Peak Protected generator cover and payment options speak to your local Peak
Representative or for further information contact: protected@peakscientific.com

Peak Scientific
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Tel: +44 141 812 8100
For further information on any of our
generator products please contact
marketing@peakscientific.com

Copyright © Peak Scientific Instruments Ltd 2018 — GeniusXE User Manual Rev 2 RSID 2299 EN —18/07/2018