Extracted text

Your local gas generation partner

Precision series
Modular gas generation
solution for GC

www.peakscientific.com

Perform with Precision
Specifically designed and engineered for GC laboratory applications, the Precision series
represents the cutting-edge of Peak Scientific innovation in on-demand gas generator design.
Combining convenience and reliability in a stackable, modular and compact design, Precision
is the safe and practical choice for your GC gas requirements.

Why Precision is the complete solution for GC gas


Continuous and consistent source of laboratory-grade gas for GC



Safer and more convenient than pressurized cylinders, dewars or bulk storage



Compact, modular, stackable system allowing maximum use of valuable laboratory floor or
bench space



Nitrogen, Hydrogen and Zero Air models, with various flow rates available



Complete gas solution for carrier, detector, reference, flame support and sample
preparation



Combine modules in a single stack to deliver various gas types, flows and purities
required to meet your specific needs



Economical solution—long term fixed-cost investment, eliminate risk of rising gas
cylinder prices



Very low lifetime maintenance requirement



Proven and robust safety systems including internal leak detection on Hydrogen models



LED front panel status indicator and touch screen panel on Hydrogen models



12 month warranty across the range, 3 year PEM cell warranty on Hydrogen models



Complete peace of mind and lifetime performance with [Peak Protected] generator
care plans (available separately), protecting your productivity

Page 2

Tailor a Precision system to suit your needs
The key to Precision is the flexibility it gives in specifying models best suited to your application.
The N2 and H2 generators are available in two variants — Standard and Trace laboratory
grades. Recommendation of the correct model depends on the use of the product. For most GC
detectors, the standard grade purity is sufficient, but for carrier gas use, the trace models are
recommended to ensure the lowest possible baseline and precision in your results.

Zero Air

Nitrogen
Trace

Hydrogen
Trace

Zero Air + Compressor
Zero Air + Hydrogen
Zero Air + Nitrogen +
Hydrogen Trace

(For Hydrocarbon free flame
support gas supply)

(Supply for detector
combustion mixture)

(Total solution for detector and
carrier for GC-FID)

Compressor

Zero Air + Nitrogen Trace + Hydrogen Trace + Compressor
(Total GC solution for detector and carrier (N2 or H2)
with air compressor)

Page 3

Compact and convenient
Precision series affords you many benefits over traditional sources of laboratory gas such
as cylinders. Above all, investing in a Precision system removes the need for nitrogen, zero air
and hydrogen cylinders from your laboratory altogether. Offering a more convenient
(no re-ordering and swapping tanks), safer (no risk of injury, leak or explosion), and economic
(no ongoing gas purchase costs) solution. All in a compact, space-saving form, sitting either on
the bench next to your GC or floor-stacked.

Illustration to show scale

Page 4

About helium and hydrogen
Helium is considered by many working with GC to be the carrier gas of choice. It is inert, relatively safe
and does its chromatographic job very well. However, as a finite resource, helium is rapidly increasing in
price and its long-term availability is not guaranteed to GC users.
As a result, many GC labs and instrument manufacturers are now making a switch from helium to hydrogen.
By making the switch, laboratories can unlock a number of advantages in terms of performance, economics
and productivity. All in addition to convenience and lower carbon footprint (no gas deliveries and stock
management).

There are major benefits of using hydrogen as your carrier gas:



Increased speed: increasing the linear velocity of
your carrier gas allows for shorter run times, thereby
increasing the throughput of your laboratory
samples. Hydrogen out-performs helium at

higher velocities (see van Deemter curve, below)
meaning quicker run times without compromising
performance of analysis.

Lower temperature separations: with lower elution
temperatures of analytes, it may be possible to reduce
the maximum GC oven temperature needed for your
analysis, potentially extending column lifetime.

N2

1.00

HETP

Use of shorter, narrower bore columns with
hydrogen carrier gas can improve efficiency and
resolution meaning better chromatography.

He

0.75
0.50

H2

0.25

10

20

30

40

50

60

u (cm/sec)

What about safety?
Hydrogen gas is already being used commonly in the laboratory for a variety of purposes. It is the fuel
used for the most commonly used detector (FID) and is therefore already present in most GC Labs.
Nevertheless we understand any concerns you may have and have therefore incorporated numerous
safety features in our Hydrogen generators’ design:


Minimal storage of hydrogen



Mechanical shut down fail safe



Automatic shut down on leak detection



Hydrogen generation on demand

Page 5

Precision Hydrogen
Hydrogen Generator for GC

Key Features
))

Suitable for fuel gas at standard detection limits

))

99.9995% Purity

))

Internal leak detection with automatic shutdown
features

))

Automatic loading pump as standard

))

Simple maintenance, limited to replacing de-ionizer
cartridge and silica gel

))

Short and easy start-up and shutdown procedures

))

Compact, space-saving modular design

))

Creates hydrogen on demand, minimal storage of
hydrogen in the system

))

Peak offers a 3 year cell warranty with this generator as
standard

))

12 month comprehensive on-site warranty

Precision Hydrogen Trace
Hydrogen Generator for GC

Page 6

Key Features
))

Suitable for flame gas and carrier gas at trace detection
limits

))

99.9999% Purity

))

Internal leak detection with automatic shutdown
features

))

Proven PEM technology to generate hydrogen safely and
reliably

))

Regenerative PSA dryers to ensure highest level of purity

))

Automatic loading pump as standard

))

Maintenance limited to replacing de-ionizer cartridge

))

Short and easy start-up and shutdown procedures

))

Combine multiple units for higher flow requirements

))

GC in-oven hydrogen leak detector available as an
optional extra

))

Peak offers a 3 year cell warranty with this generator as
standard

))

12 month comprehensive on-site warranty

Technical Specifications
Max Flow Rate

Hydrogen,
100cc

Hydrogen,
200cc

Hydrogen,
300cc

Hydrogen,
450cc

Hydrogen,
1200cc

100 cc/min

200 cc/min

300 cc/min

450 cc/min

1200 cc/min

Max Pressure

100 psi /6.9 bar

Purity

99.9995%

Gas Outlets

1 x 1/8” Swagelok compression fitting

Water Purity Requirement
Water Consumption

1 Mohm-cm
up to 0.12 L/ day

up to 0.24 L/day

up to 0.36 L/day

up to 0.53 L/day

Operating Temperature

10°C - 35°C / 50°F - 95°F

Electrical Requirements

110 / 230 V 50 / 60 Hz max 6

Power Consumption

400 Watts

400 Watts

400 Watts

Heat Output

400 Watts

406 x 380 x 540 mm / 16 x 15 x 21.3’’

Generator Weight

29 Kg (64 lbs)

Noise Level

Max Flow Rate

Hydrogen Trace 250

Hydrogen Trace 500

Hydrogen Trace 1200

250 cc/min

500 cc/min

1200 cc/min

100 psi / 6.9 bar

Purity

99.9999%

Gas Outlets

1 x 1/8” Swagelok compression fitting

Water Purity Requirement

1 Mohm-cm
0.17 - 0.46 L/day

Operating Temperature
Electrical Requirements
Power Consumption

0.4 - 1.2 L/day

Generator Weight
Noise Level

up to 1.2 L/day

10°C - 35°C / 50°F - 95°F
110 / 230 V 50 / 60 Hz max 6 A
477 Watts

787 Watts

Heat Output
Generator Dimensions (HxWxD)

38 Kg (83.8 lbs)

Silent in operation

Max Pressure

Water Consumption

787 Watts

up to 1000 BTU/hr

Generator Dimensions (HxWxD)

Technical Specifications

up to 2.1 L/day

110 / 230 V 50 / 60 Hz 2.3 - 4.8 A
787 Watts

up to 1000 BTU/ hr
406 x 380 x 540 mm / 16 x 15 x 21.3’’
29 Kg (64 lbs)

38 Kg (83.8 lbs)
Silent in operation

Page 7

Precision Nitrogen
Nitrogen Generator for GC

Key Features
))

Suitable as make-up gas and sample preparation at
standard detection limits

))

Nitrogen generated on demand, as and when it is
required

))

Constant and consistent supply, avoid running out of gas
during analysis

))

Avoid contaminants entering system as result of
changing over empty cylinders

))

Dedicated Precision compressor module available

))

Ultra-fast start-up time, quick to reach standard
operating purity

))

Minimum maintenance with an annual filter change

))

12 month comprehensive on-site warranty

Precision Nitrogen Trace
Nitrogen Generator for GC

Key Features

Page 8

))

Suitable for carrier gas, make-up gas and
sample preparation

))

This generator produces “zero nitrogen” on demand
from a compressed air source

))

Regenerative CMS columns remove oxygen and
moisture

))

Catalyst chamber to remove hydrocarbons (as methane)
to replacements

))

Ultra-fast start-up time, quick to reach standard
operating purity

))

Minimum maintenance with an annual filter change

))

Compact, space-saving modular design

))

12 month comprehensive on-site warranty

Technical Specifications
Max Flow Rate

Nitrogen, 250cc
250 cc/min

Max Pressure

Nitrogen, 600cc

Nitrogen, 1000cc

600 cc/min

1000 cc/min

80 psi / 5.5 bar

Purity

> 99.9995%

Gas Outlets

1 x 1/4 " BSPP

Min/Max Air Inlet Pressure

6.9-8.3 bar / 100-120 psi

Min Air Inlet Flow

35 lpm

Min Inlet Air Quality

ISO8573 - 1:2010 Class 1.4.1

Phthalates

None

Suspended Liquids

None

Start-Up Time For Purity

1.5 hours

Operating Temperature

5°C - 35°C / 41°F - 95 °F

Electrical Requirements

100 / 240 V 50 / 60 Hz 0.03 A

Power Consumption

39.1 - 40.7 Watts

Heat Output

Up to 140 BTU/Hr

Generator Dimensions (HxWxD)
Generator Weight

256 x 380 x 540 mm / 10.1 x 15 x 21.3’’
21 Kg (46.3 lbs)

21Kg (46.3 lbs)

Noise Level

Technical Specifications
Max Flow Rate

Silent in operation

Nitrogen Trace, 250cc
250 cc/min

Max Pressure

Start-Up Time For Purity

1000 cc/min

1 x 1/4" BSPP

Min/Max Air Inlet Pressure

Suspended Liquids

600 cc/min


Gas Outlets

Phthalates

Nitrogen Trace, 1000cc

> 99.9995%

Hydrocarbon Content

Min Air Inlet Flow

Nitrogen Trace, 600cc
80 psi / 5.5 bar

Purity

Min Inlet Air Quality

120-145 psi / 8.3-10 bar
18 lpm

22 lpm
ISO8573 - 1:2010 Class 1.4.1
None
None
1.5 Hours

Operating Temperature

5°C - 35°C / 41°F - 95°F

Electrical Requirements

110 / 230V 50 / 60 Hz 4.4 - 2.1 A

Power Consumption
Heat Output
Generator Dimensions (HxWxD)
Generator Weight
Noise Level

26 Kg (57.4 lbs)

484 Watts
up to 1650 BTU/Hr
406 x 380 x 540 mm / 16 x 15 x 21.3’’
38 Kg (83.8 lbs)
Silent in operation

Page 9

Precision Zero Air
Zero Air Generator for GC

Key Features
))

Integrates seamlessly with other Precision units

))

Hydrocarbon content purity

))

Minimum lifetime maintenance requirements, no
expensive catalyst chamber replacements

))

Avoid risk of contaminants entering the system
(when switching out empty cylinders)

))

No risk of running out of gas in middle of analysis

))

Compatible with Precision Air Compressor

))

Status indicative lighting feature

))

12 month comprehensive on-site warranty

Precision Air Compressor
Air Compressor for GC

Key Features

Page 10

))

Compressed air supply for Precision Nitrogen and Zero
Air generators

))

Single unit can supply both the N2 and ZA generators in
a stack

))

Duplex compressor mounting system to dampen noise
and vibration

))

Service and repair status indicators

))

12 month comprehensive on-site warranty

Technical Specifications
Max Flow Rate

Zero Air 1.5L

Zero Air 3.5L

Zero Air 7L

Zero Air 18L

Zero Air 30L

1.5 L/min

3.5 L/min

7 L/min

18 L/min

30 L/min

Max Pressure

80 psi / 5.5 bar

Hydrocarbon Concentration (as Methane)
Gas Outlets
Min/Max Air Inlet Pressure
Min Air Inlet Flow

100 psi / 6.9 bar

1 x 1/4" BSPP
90-145 psi / 6.2-10 bar
1.5 L/min

110 psi / 7.5 bar

3.5 L/min

Min Inlet Air Quality

7 L/min

18 L/min

110-145 psi / 7.6-10.0
bar
30 L/min

ISO8573 - 1:2010 Class 1.4.1

Phthalates

None

Suspended Liquids

None

Start-Up Time For Purity

60 minutes

Operating Temperature

5°C - 35°C / 41°F - 95°F

Electrical Requirements

110/230 VAC 50/60 Hz 2/1 A

110/230 VAC 50/60 Hz 5.4/3.3 A

110/230 VAC 50/60 Hz
11/6.7 A

Power Consumption

220 Watts or 230 Watts

594 Watts or 759 Watts

1210 Watts or
1541 Watts

up to 785 BTU/Hr

up to 2590 BTU/Hr

up to 5255 BTU/Hr

256 x 380 x 540 mm / 10.1 x 15 x 21.3’’

406 x 380 x 540 mm
/ 16 x 15 x 21.3’’

25.4 Kg / 56 lbs

41 Kg / 90.4 lbs

Heat Output
Generator Dimensions (HxWxD)
Generator Weight
Noise Level

Technical Specifications
Flow Rate
Max Pressure
Gas Outlets

156 x 380 x 540 mm / 6.2 x 15 x 21.3’’
16 Kg / 35.3 lbs

Silent in operation

Air Compressor
Suitable for various Precision combinations
120 psi (8.27 bar)
1 x 1/4" BSPP

Operating Temperature

5°C - 35°C / 41°F - 95°F

Electrical Requirements

110-115 V 50/60 Hz 10 A / 208-230 V 50/60 Hz 2.45 A

Power Consumption
Heat Output
Generator Dimensions (HxWxD)
Generator Weight

510 - 1150 Watts
1740 - 3922 BTU/Hr
406 x 380 x 540 mm / 16 x 15 x 21.3’’
42 Kg / 92.6 lbs

Page 11

Model Description

110v

230v

110/230v

Precision Nitrogen Trace, 250cc

62-0251

62-0250

-

Precision Nitrogen Trace, 600cc

62-0601

62-0600

Precision Nitrogen Trace, 1L

62-1001

62-1000

-

Precision Zero Air, 1.5L

60-1501

60-1500

-

Precision Zero Air, 3.5L

60-3501

60-3500

-

Precision Zero Air 7L

60-0008

60-0007

-

Precision Zero Air 18L

60-0019

60-0018

-

Precision Zero Air, 30L

60-0031

60-0030

-

Precision Air Compressor

65-1555

65-0555

-

Precision Nitrogen, 250cc

-

-

61-0250

Precision Nitrogen Headspace 250cc

-

-

65-3000

Precision Nitrogen, 600cc

-

-

61-0600

Precision Nitrogen, 1L

-

-

61-1000

Precision Hydrogen, 100cc

-

-

63-0100

Precision Hydrogen, 200cc

-

-

63-0200

Precision Hydrogen, 300cc

-

-

63-0300

Precision Hydrogen, 450cc

-

-

63-0450

Precision Hydrogen 1200cc

-

-

3300843

Precision Hydrogen Trace, 250cc

-

-

64-0250

Precision Hydrogen Trace, 500cc

-

-

64-0500

Precision Hydrogen Trace 1200cc

-

-

3301768

Accessories
Description
Part No

Annual Service Kit

www.peakscientific.com/ordering

Water Bottle 4L

Water Bottle 8L

Hydrogen Leak Detector (GC in-oven)

4L Water bottle for use
with Precision Hydrogen &
Hydrogen Trace

8L Water bottle for use
with Precision Hydrogen &
Hydrogen Trace

Hydrogen Gas Detector for use with Precision
Hydrogen Trace models

www.peakscientific.com/ordering

Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries across every continent
around the world. This allows us to provide an industry-leading rapid response service to our customers. With [Peak Protected],
your laboratory’s productivity becomes our top priority.
To discuss our different coverage levels and payment options speak to your local Peak Representative or for further
information contact: protected@peakscientific.com.

Local Peak Office
[Peak Protected] direct
Protected by approved agents
Third party coverage

Peak Scientific UK
Tel: +44 (0)141 812 8100
Fax: +44 (0)141 812 8200

Peak Scientific Australia
Tel: +61 1300 965 352 (AUS)
Tel: 0800 004 486 (NZ)

Peak Scientific North America
Tel: +1 866 647 1649
Fax: +1 978 608 9503

For a full list of our worldwide
office locations, please visit:
Web: www.peakscientific.com
Email: discover@peakscientific.com

Copyright © Peak Scientific Instruments Ltd 2018 — Precision Brochure Rev12 PN 00-4074 RSID 0087 E —20/12/2018

Search for similar resources

Remove