Precision Zero Air (All Models)
User Manual

Copyright © Peak Scientific Instruments Ltd 2018 — Precision Zero Air User Manual Rev 6 RSID 397 EN —16/10/2018

Contents
Change History
3
How to use this Manual
3
Introduction 4
Warranties and Liabilities
5
Safety Notices
6
Symbols 6
Safety Notice to Users
6
Declaration of Conformity
7
Environmental Declaration
8
Technical Specification
9
Fittings Kit Contents
13
Unpacking Instructions
13
Installation 14
Generator Environment
14
Generator Overview
15
1.5L & 3.5L General Dimensions
15
7L & 18L General Dimensions
16
30L General Dimensions
17
1.5L & 3.5L Rear Connections
18
7L & 18L Rear Connections
19
30L Rear Connections
20
Electrical Connection
21
Air Purity
22
Class 1 Particulate
22
Class 4 Water
22
Class 1 Oil
22
Start-Up Sequence
23
On Demand Gas
23
Unusual Operation
23
Connecting to the application
24
Tubing Lengths
24
Service Requirements
25
Service Schedule
25
Service Plans
25
Peak Protected
26
Cleaning 27
Troubleshooting 28

Page 2

Change History
Rev

Comment

Name

Date

2

DOC Updates

LC

06/10/2017

3

Technical Specification Update

LC

21/12/2017

4

Cleaning Information Update

LC

28/02/2018

5

Declarations Update

LC

24/04/2018

6

Technical Content Updates

LC

16/10/2018

How to use this Manual
This manual is intended for end users and has been written as a reference document
where you can skip to the relevant information.
Users can refer to the contents page to find the relevant information.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your gas generation needs, and should
you require any further assistance or support please do not hesitate to contact Peak
Scientific or the Peak Partner from which you purchased your generator.

Page 3

Introduction
Precision is a modular system with differing flow rates that allows you to add multiple
generators as your gas and analysis demands change. The Precision Series will keep
your gas flowing with consummate accuracy and reliability, whatever your needs, while
fitting neatly into any lab space.
The Precision Zero Air generators provide hydrocarbon free air, suitable as a Flame
Support Gas at Trace and Standard detection limits.
Other features include:
• Suitable for Flame Support Gas at Trace and Standard detection limits.
• Generates Zero Air on demand from Compressed Air
• Catalyst chamber to remove Hydrocarbons (as methane) to • Minimum maintenance with only a filter change per annum.
• Small and Stackable
With the Precision Zero Air based on proven technology, they remove hydrocarbons
and other contaminants to provide Zero Air.
To ensure these generator models meet our high expectations with regards to reliability
and performance, we have tested them extensively at our manufacturing plant and with
end users around the world to ensure reliability and longevity of the system.

Page 4

Warranties and Liabilities
1. The Company warrants that it has title to the Goods.
2. Subject to the provisions of this clause the Company warrants that the Goods
shall comply in all material respects with any specification referred to in the Order
Confirmation (as the same may be amended) and shall, subject thereto, be free
from defects in material and workmanship for the lesser of a period of twelve
months from the date of delivery or thirteen months from the date of dispatch
from the factory.
3. Save as provided in this clause and except where the Goods are sold to a person
dealing as a consumer (within the meaning of the Unfair Contract Terms Act
1977) all warranties, conditions or other terms implied by statute or common
law are hereby expressly excluded save to the extent they may not be lawfully
excluded. When the Goods are sold to a consumer within the meaning of the Unfair
Contract Terms Act 1977 their statutory rights are not affected by the provisions of
this clause.
4. In the event of the Customer making a claim in respect of any defect in terms of
clause 2 hereof the Customer must.
1. Reasonably satisfy the Company that the Goods have been properly installed,
commissioned, stored, serviced and used and without prejudice to the generality
of the foregoing that any defect is not the direct or indirect result of lack of repair
and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or
incorrect spare parts
2. Allow the company to inspect the Goods and/or any installation and any relevant
packaging as and when reasonably required by the Company.
5. Subject to the Company being notified of any defect as is referred to in sub-
clause 2 hereof within a reasonable time of it becoming apparent and subject always
to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or
repair the defective Goods or refund a proportionate part of the Price. The Company
shall have no further liability to the Customer (save as mentioned in sub-clause 6
hereof).
6. The Company shall be liable to indemnify the Customer in respect of any claim
for death or personal injury to any person in so far as such is attributable to the
negligence or breach of duty of the Company or any failure by the Company to
comply with the provisions of sub-clause 2 hereof.
7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect
of any claim by the Customer for costs, damages, loss or expenses (whether direct,
indirect, consequential or otherwise) or indemnity in any respect howsoever arising
including, but not by way of limitation, liability arising in negligence (other than
pursuant to clause 6 above) that may be suffered by the Customer or any third
party.

Page 5

Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this manual refer to the most
likely potential hazards, but by definition cannot be all inclusive. If the user employs
an operating procedure, item of equipment or a method of working which is not
specifically recommended by Peak Scientific, the user must ensure that the equipment
will not be damaged or become hazardous to persons or property.

Symbols
This manual uses the following symbols to highlight specific areas important to the safe
and proper use of the generator.

WARNING

A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.

CAUTION

A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the generator or the application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the generator has been removed
before proceeding.

Safety Notice to Users

WARNING

WARNING

These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.

WARNING

Page 6

Declaration of Conformity
We

Peak Scientific Instruments Ltd.

Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:


Equipment:

Zero Air Generator



Models:

Precision Zero Air 1.5L & 3.5L

To which this declaration relates, is in conformity with the applicable EC directives,
harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for Measurement, Control and Laboratory Use
– EMC Requirements.
• FCC47 CFR Part 15 Class B
Unintentional radiators; Conducted and Radiated emissions limits.
All evaluation, testing and certification issued by:


Nemko Canada Inc.

York EMC Services LTD



303 River Road, Ottawa

Grangemouth Technology Park,



Ontario, Canada

Earls Road, Grangemouth, UK



K1V 1H2 FK3 8UZ

Signed: Name: Chris Pugh
Date:

Page 7

10/07/2018

Position:

Chief Technology Officer

Declaration of Conformity
We

Peak Scientific Instruments Ltd.

Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:


Equipment:

Zero Air Generator



Models:

Precision Zero Air 7L & 18L


To which this declaration relates, is in conformity with the applicable EC directives,
harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for Measurement, Control and Laboratory Use
– EMC Requirements.
• FCC47 CFR Part 15 Class B
Unintentional radiators; Conducted and Radiated emissions limits.
All evaluation, testing and certification issued by:


York EMC Services Ltd



Unit 1, Grangemouth Technology Park,

Earls Road, Grangemouth


FK3 8UZ

Signed: Name: Chris Pugh
Date:

Page 8

19/06/2015

Position:

Chief Technology Officer

Declaration of Conformity
We

Peak Scientific Instruments Ltd.

Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:


Equipment:

Zero Air Generator



Models:

Precision Zero Air 30L


To which this declaration relates, is in conformity with the applicable EC directives,
harmonized standards, and other normative requirements.
• Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement,
Control and Laboratory Use.
• Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for Measurement, Control and Laboratory Use
– EMC Requirements.
• FCC47 CFR Part 15 Class B
Unintentional radiators; Conducted and Radiated emissions limits.
All evaluation, testing and certification issued by:


Nemko Canada Inc.



303 River Road, Ottawa



Ontario, Canada


K1V 1H2

Signed: Name: Chris Pugh
Date:

Page 9

10/07/2018

Position:

Chief Technology Officer

Environmental Declaration
We

Peak Scientific Instruments Ltd.

Of

Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE

Declare that:


Equipment:

Zero Air Generator



Models:

Precision Zero Air 1.5L, 3.5L, 7L, 18L & 30L

Is fully compliant with the following Directives
• 2012/19/EU

WEEE (Waste of Electrical and Electronic Equipment)

• 2011/65/EU

RoHS 2 (Restriction of Hazardous Substance)

Peak Scientific Instruments Ltd fully complies with its obligations towards the European
WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These
obligations are being met within the B2B compliance group.
Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to
ensure that our products comply with the principles and requirements of the European
recast RoHS (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar
directives in the United States and China, for example, have also been captured within
this program.
Where a specific certificate of compliance is required, this can be requested, on
a product serial number basis, directly from Peak Scientific Instruments Ltd, by
contacting us through our website on www.peakscientific.com
Signed: Name: Chris Pugh
Date:

Page 10

02/06/2016

Position:

Chief Technology Officer

Technical Specification
Precision Zero Air
Environment
1.5L

Minimum Operating Ambient Temperature
Maximum Operating Ambient Temperature
Maximum Altitude
Maximum Relative Humidity
Minimum Storage Temperature*
Maximum Storage Temperature*

3.5L

5°C (41°F)
35°C (95°F)
2000 m
80% Non-Condensing
-20°C (-4°F)
60°C (140°F)

Inlet Conditions
Min/Max Inlet Air Pressure
Minimum Air Inlet Flow
Minimum Air Inlet Quality
Maximum Inlet CH4 Concentration

6.2-10 bar (90-145 psi)
1.5 l/min
3.5 l/min
ISO 8573-1:2010 Class[1.4.1]
100ppm CH4

Generator Outlets
Maximum Gas output Pressure
Maximum Outlet Flow Rate
Start-up time
Outlet CH4 Concentration
Particles
Phthalates
Suspended Liquids
Gas Outlets
Drain Outlets

5.5 bar (80 psi)
1.5 l/min

3.5 l/min
60 minutes
NONE
NONE
1 x ¼” BSPP
NONE

Electrical Requirements
Voltage
Frequency
Current
Input Connection
Power Cord (Supplied)
Pollution Degree
Insulation Category

115VAC
50/60 Hz
2A

230VAC
50/60 Hz
1A

C14 Plug
C13 Socket to Local Connection
2
II

General
Dimensions cm (inches) WxDxH
Generator Weight Kg (lbs)
Shipping Weight Kg (lbs)
Page 11

38.0 (14.9) x 54.0 (21.2) x 15.6 (6.14)
16 (35)
19 (41.9)

Technical Specification
Precision Zero Air
Environment
7L

Minimum Operating Ambient Temperature
Maximum Operating Ambient Temperature
Maximum Altitude
Maximum Relative Humidity
Minimum Storage Temperature*
Maximum Storage Temperature*

18L

5°C (41°F)
35°C (95°F)
2000 m
80% Non-Condensing
-20°C (-4°F)
60°C (140°F)

Inlet Conditions
Min/Max Inlet Air Pressure
Minimum Air Inlet Flow
Minimum Air Inlet Quality
Maximum Inlet CH4 Concentration

7.5-8.6 bar (110-125 psi)
7 l/min
18 l/min
ISO 8573-1:2010 Class[1.4.1]
100ppm CH4

Generator Outlets
Maximum Gas output Pressure
Maximum Outlet Flow Rate
Start-up time
Outlet CH4 Concentration
Particles
Phthalates
Suspended Liquids
Gas Outlets
Drain Outlets

5.5 bar (80 psi)
7 l/min

18 l/min
60 minutes
NONE
NONE
1 x ¼” BSPP
NONE

Electrical Requirements
Voltage
Frequency
Current
Input Connection
Power Cord (Supplied)
Pollution Degree
Insulation Category

115VAC
50/60 Hz
5.4A

230VAC
50/60 Hz
3.3A

C14 Plug
C13 Socket to Local Connection
2
II

General
Dimensions cm (inches) WxDxH
Generator Weight Kg (lbs)
Shipping Weight Kg (lbs)
Page 12

38.0 (14.9) x 54.0 (21.2) x 25.6 (10.0)
25.4 (55.9)
44 (97)

Technical Specification
Precision Zero Air
Environment
30L

Minimum Operating Ambient Temperature
Maximum Operating Ambient Temperature
Maximum Altitude
Maximum Relative Humidity
Minimum Storage Temperature*
Maximum Storage Temperature*

5°C (41°F)
35°C (95°F)
2000 m
80% Non-Condensing
-20°C (-4°F)
60°C (140°F)

Inlet Conditions
Min/Max Inlet Air Pressure
Minimum Air Inlet Flow
Minimum Air Inlet Quality
Maximum Inlet CH4 Concentration

7.6-10 bar (110-145 psi)
30 l/min
ISO 8573-1:2010 Class[1.4.1]
100ppm CH4

Generator Outlets
Maximum Gas output Pressure
Maximum Outlet Flow Rate
Start-up time
Outlet CH4 Concentration
Particles
Phthalates
Suspended Liquids
Gas Outlets
Drain Outlets

6.9 bar (100 psi)
30 l/min
60 minutes
NONE
NONE
1 x ¼” BSPP
NONE

Electrical Requirements
Voltage
Frequency
Current
Input Connection
Power Cord (Supplied)
Pollution Degree
Insulation Category

115VAC
50/60 Hz
9A

230VAC
50/60 Hz
6.7A

C14 Plug
C13 Socket to Local Connection
2
II

General
Dimensions cm (inches) WxDxH
Generator Weight Kg (lbs)
Shipping Weight Kg (lbs)
Page 13

38.0 (14.9) x 54.0 (21.2) x 40.6 (15.8)
41 (90.3)
43 (94.7)

Unpacking
Although Peak Scientific takes every precaution with safe transit and packaging, it is
advisable to fully inspect the unit for any sign of transit damage.
Check ‘SHOCKWATCH’ and ‘TIP-N-TELL’ labels for signs of rough handling prior to
unpacking.

Any damage should be reported immediately to the carrier and Peak Scientific or the
Peak Partner from where the unit was purchased.
Follow the unpacking instructions posted on the side of the crate. It will require
two people to remove the unit from the shipping crate and to manoeuvre the air
compressor onto the bench.
Please save the product packaging for storage or future shipment of the generator.
Note: Included with the generator is a “Fittings Kit” containing mains power leads for
UK, EU & US and also all the required fittings and warranty registration card. Be careful
not to discard these with the packaging. 

Page 14

Fittings Kit Contents
Supplied in the Fittings Kit are all the fittings required to connect the generator to the
application. The contents of the Fittings Kit are as follows:
1. PTFE Tubing x 3m
2. ¼” Compression Fitting x 1
3. 1⁄8” Compression Fitting



x 1

4. UK Mains Power Cable x 1
5. EU Mains Power Cable x 1
6. US Mains Power Cable 110v

x1

7. US Mains Power Cable 230v

x1

All of the generators output ports are located on the output panel at the rear of the
unit.

Unpacking Instructions
The unit weight constitutes a two person lift and as such, safe lifting practices should
be employed; do not attempt to lift on your own, as you will significantly increase the
chance of injury & damage to yourself and others around you.
1. Remove the screws encircled in red around the bottom of the crate lid and lift
upwards.
2. Next, with someone on either side of the unit, position your hands underneath the
unit ready to lift.
3. Ensuring your knees are bent and your back is straight, lift the unit to the desired
location.

Page 15

Installation
Generator Environment
The generator is designed for indoor use only. Storing of corrosive substances near
the generator or its compressed air supply is not recommended. Saline salt solution
spillages around the generator or its compressed air supply should be cleaned up
immediately. It should be installed adjacent to the application(s) it is supplying. If this
is not convenient then the unit can be sited elsewhere, however, consideration should
be made of the lengths of pipe runs as pressure drops can result from extended runs of
pipe.
Performance of the generator (like all sophisticated equipment) is affected by ambient
conditions. Note should also be taken to the proximity of Air Conditioning outlets.
These can sometimes give rise to “pockets” of air with high relative humidity. Operation
of the unit within such a pocket could adversely affect its performance. Consideration
should also be given to the air flow around the unit. It is recommended that an air gap
of 75mm (3”) should be maintained down both sides and at the rear of the unit. Please
refer to the drawing below for the general dimensions of the unit.
Please ensure generator is operated in a well ventilated environment and is positioned
so as to permit easy electrical disconnection if required.
Minimum Operating Ambient Temperature:

5 °C (41 °F)

Maximum Operating Ambient Temperature:

35 °C (95 °F)

Page 16

Generator Overview
1.5L & 3.5L General Dimensions

380 mm / 14.9”
156mm / 6.4”

540 mm / 21.2”

The generator must always be placed on a flat, level surface. Failure to
do so will affect the performance of the generator.
WARNING

Page 17

7L & 18L General Dimensions

380 mm / 14.9”

256 mm / 10"

540 mm / 21.2”

The generator must always be placed on a flat, level surface. Failure to
do so will affect the performance of the generator.
WARNING

Page 18

30L General Dimensions

380 mm / 14.9”

406mm / 15.9”

540 mm / 21.2”

The generator must always be placed on a flat, level surface. Failure to
do so will affect the performance of the generator.
WARNING

Page 19

1.5L & 3.5L Rear Connections

WARNING

Ensure all connections are linked to the correct application and are
completed by trained personnel.Generator must be switched off and
unplugged prior to any cleaning or maintenance operation.

1/4" Compression Fitting
1/8” Compression Fitting

Mains Cable

Page 20

7L & 18L Rear Connections

WARNING

Page 21

Ensure all connections are linked to the correct application and are
completed by trained personnel.Generator must be switched off and
unplugged prior to any cleaning or maintenance operation.

30L Rear Connections

WARNING

Page 22

Ensure all connections are linked to the correct application and are
completed by trained personnel.Generator must be switched off and
unplugged prior to any cleaning or maintenance operation.

Electrical Connection
Connect the Generator to an appropriate 110 or 230 volt single-phase supply, refer to
the generator serial plate for input specification and ensure your supply matches the
requirements.
If the appropriate power cord is not supplied; a new plug, rated to at least 12 amps, can
be fitted by a qualified electrician.
If a substitute mains power supply cable is used ensure that it has adequate rating and
appropriate approvals for the country of operation . Failure to do so can damage the
generator

WARNING

This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE
EARTHED. Before connecting the unit to the mains supply, please
check the information on the serial plate. The mains supply must be of
the stated AC voltage and frequency.

EARTH/GROUND (E):-

Green & Yellow or

Green

LIVE (L):-

Brown

or

Black

Neutral (N):-

Blue

or

White



Electrical requirements are 110 or 230VAC nominal +/- 10% depending on chosen
model. However, running continuously at voltages outwith this is not recommended.
Extended periods at extremes can have a detrimental effect on the operation and life of
the Generator.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment maybe impaired.
WARNING

Page 23

Air Purity
The Precision Zero Air Series generator should be connected to an air supply that, as a
minimum, meets ISO8753-1:2010 Class 1.4.1

Class 1 Particulate
In each cubic metre of compressed air, the particulate count should not exceed 20,000
particles in the 0.1 - 0.5 micron size range, 400 particles in the 0.5 - 1 micron range and
10 particles in the 1 - 5 micron size range.

Class 4 Water
A pressure dew point (PDP) of +3°C or better is required and no liquid water is allowed.

Class 1 Oil
In each cubic metre of compressed air, not more than 0.01mg of oil is allowed. This is a
total level for liquid oil, oil aerosol and oil vapour.

Page 24

Start-Up Sequence
Switch the generator on using the power switch on the rear panel of the unit. Please
note: On 30L generators, air will only flow through the generator when the power is
switched on. The LED’s on the front panel will illuminate YELLOW for the start-up
period.

YELLOW for 60 Minutes

On completion of the start-up period, up to 60 minutes, the fascia will illuminate
GREEN or BLUE (70-**** Part Numbers Only). GREEN
The generator
/ BLUE is now ready to be used.

On Demand Gas
The generator system will produce zero air on demand. If the application is operating
and requires a gas flow, the generator it is connected to will supply this to suit the
requirements of the application. If the application requirement for gas stops, the
system will also stop. If the demand from the application starts again, the system will
automatically start again to suit the demand.

Unusual Operation
If at any time the generator begins to emit excessive noise or vibration, then it should
be switched off and you should contact Peak Scientific or the Peak Partner from which
the generator has been purchased.
Page 25

Connecting to the application
Once the initial purge run of 60 minutes has completed the generator is now ready to
be connected to the application(s).
The pressure must be allowed to dissipate before connecting the
generator to the application(s)
CAUTION

Attach the 1/8” compression fitting to the outlet of the generator. Using either 1/8”
copper or stainless steel tubing, connect the outlet of the generator to the inlet of the
application.
If you require more tubing than is supplied please refer to the Tubing Lengths section.

CAUTION

Once the tubing is connected to the application, please ensure that it
is thoroughly checked for being leak-tight. Even the slightest leak in
the gas supply between the generator and the application can lead to
a reduction in efficiency.

Tubing Lengths

CAUTION



The diameter of the tubing which will be connected to the gas outlet is
important and is determined by the length of tubing required. Failure
to follow these recommendations could lead to an excessive pressure
drop between the generator and its application.


Use ¼”/3⁄16” (¼” O/D, 3⁄16” I/D) P.T.F.E. tubing.


> 10 - 40 meters: Use 3⁄8”/ 5⁄16” (3⁄8” O/D, 5⁄16” I/D). Tubing and fittings not supplied
in the fittings kit.

> 40 metres:


Please contact Peak Scientific with the relevant distance and
we will calculate the flow resistance and the tubing size required.

A combination of ¼”/3⁄16” and 3⁄8”/5⁄16” tubing may be used to ensure that there is no large
diameter tubing within the lab (i.e. for the first 20 meters from the generator use 3⁄8”/5⁄16”
and the final 10 meters to the application use ¼”/3⁄16” tubing). Keep the connections and
bends to a minimum.

Page 26

Service Requirements
Only Peak approved and supplied components should be used on the Precision Zero
Air range

Service Schedule
Purchase Interval

Component

12 months

Precision Zero Air Annual Service Kit

Page 27

Visit
www.peakscientific.com/
ordering

Peak Protected
With Peak Scientific you invest in not only a product but peace of mind. With a network of
certified Peak engineers stationed throughout the globe, Peak’s rapid response team are
never far away and our commitment is to keep your generator running day in, day out,
protecting your laboratory workflow.

[Peak Protected] can provide…

Installation

A dedicated Peak engineer will visit
your lab to install and setup your
generator

IQ/OQ

Certified assurance for applications
requiring documented qualification

Complete plan

Swift response by a Peak Service
Engineer within 72 hours & planned
preventative maintenance

Spares

Genuine Peak parts with express
delivery, ensuring optimal
performance and lifetime

Premium Protected

Guaranteed rapid on-site response
within 24 hours & planned
preventative maintenance

Technical Support Hotline

Around the clock support by phone
or online with our global technical
helpdesk

To find out more about protecting your investment visit: www.peakscientific.com/protected

Page 28

Cleaning
Clean the outside of the generator only using warm soapy water and a clean damp
cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.
Cleaning should only be undertaken with the power switched off and
the power cord removed from the rear of the Generator.

CAUTION

Under no circumstances should any solvents or abrasive cleaning
solutions be used as these can contain fumes that could be harmful to
the generator. Chlorine-based bleaches/cleaning solutions should not
be used on the generator or within their operating environment.
Care should be taken with Leak Detections Liquids.

CAUTION

Page 29

Troubleshooting
Problem

Possible Solution
• Ensure power cord is plugged into the
generator and that the power socket is
turned on.

The generator will not switch on and the
power switch does not illuminate.

• Check the fuse in the power cord plug.

The fascia LED’s have not illuminated but the
power switch is illuminated.

• Contact your service provider.

The instrument is reporting low pressure.

• Contact your service provider.

• Check for leaks between the generator
and instrument.
• Contact your service provider.

The fascia Yellow illumination does not
change to green/blue.

Page 30

• Contact your service provider.

Go Online or Complete and Return
We know that registering any of your recently purchased products is not the
first thing on your mind- but it is very important to both of us. Not all warranties
are alike and Peak Scientific stand out against other gas suppliers as we offer a
comprehensive, quick response, on-site warranty. This means that in the very
unlikely case that your gas generator develops a fault we have rapid support
teams on-hand around the world who are able to come to your lab and get you
back up and running in no time.
Register for your comprehensive 12 month on-site warranty with ease online at
www.peakscientific.com/protected.
Alternatively, you can send the completed form to Peak Scientific by post or
email at warranty@peakscientific.com.

Go Online or Complete and Return
You can register for your FREE 12 month Warranty with ease online at
www.peakscientific/protected.
Alternatively, you can send the completed form to Peak Scientific by post or
email at warranty@peakscientific.com.

Product Warranty Registration
Contact name
Email address
Company
Address
City/town
Postcode
Country
Telephone
Generator serial #
Model type
Installation date
Do you still use an
alternative gas solution i.e.
cylinders or bulk liquid?

Yes

What gas requirements do
you have in your lab?

Hydrogen

No

Nitrogen

Zero Air

Extend your cover with
Peak Scientific offer comprehensive gas generator after sales support packages.
Peak [Protected] aftercare support can guarantee an on-site response within
72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time
fix rate. See our enclosed Peak [Protected] leaflet for further information.
Important!
You have 1 month to register your Peak Scientific product from the date of installation. Once registered
the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your
generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com.
For generators that remain unregistered after 1 month from the shipment date, the warranty will be
considered active from the date of factory dispatch.
* Complete Plan only






Important!
You have 1 month to register your Peak Scientific product from the date of
installation. Once registered the warranty will be honoured for a period of 12
months. If you wish to defer the installation of your generator, you must notify
Peak Scientific immediately by emailing warranty@peakscientific.com. For
generators that remain unregistered after 1 month from the shipment date, the
warranty will be considered active from the date of factory dispatch.
Page 31

Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries
across every continent around the world. This allows us to provide an industry-leading rapid response
service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top
priority.
To discuss Peak Protected generator cover and payment options speak to your local Peak
Representative or for further information contact: protected@peakscientific.com

Peak Scientific
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Tel: +44 141 812 8100
Fax: +44 141 812 8200
For further information on any of our
generator products please contact
marketing@peakscientific.com

Copyright © Peak Scientific Instruments Ltd 2018 — Precision Zero Air User Manual Rev 6 RSID 397 EN —16/10/2018