Infinity 50 Series - User Manual
Original PDF File16.6 MB |
Download |
View directly in browser16.6 MB |
View in browser |
Resource ID
177
Access
Open
Contributed by
Derek Rennie
Updated date
14 August 24
Review date
01 May 24
Title
Infinity 50 Series - User Manual
Revision Number
6
Revision Details
SMZ added - DL
Keywords
Infinity, 50, Series, User, Manual, 5010, 5020, 5030, 5040, 5050, 5060, 5070, 5080
Product Range
Infinity
Company Brand
Peak Scientific
Reviewed on 3rd may 2017 - LC
Extracted text
2024
Rev 6 - 11/04/2024
EU Declaration of Conformity
UK Declaration of Conformity
9
10
11
13
14
14
14
15
16
18
18
19
20
20
20
21
21
21
22
23
24
25
26
27
Page 2
28
29
30
31
32
33
34
35
CSA Compliance Statement
36
Supported Maintenance Guide
37
(Infinity 5010 - 40 & 9010 - 40 series)
Service Parts List
38
(Infinity 5010 - 40 & 9010 - 40 series)
Supported Maintenance Guide
39
(Infinity 5050 - 80 & 9050 - 80)
Service Parts List
(Infinity 5050 - 80 & 9050 - 80)
Page 3
40
6
SMG Guide Added
Page 4
Cleo Denholm
24/06/2024
Page 5
Page 6
Page 7
EU Declaration of Conformity
•
Low Voltage Directive 2014/35/EU
•
Electromagnetic Compatibility Directive 2014/30/EU
•
Restriction on the use of certain hazardous substances in electronic equipment
(RoHS) Directive 2011/65/EU as amended by EU 2015/863.
•
FCC 47 CFR Part 15 class A
Page 8
UK Declaration of Conformity
•
The Electrical Equipment (Safety) Regulations 2016 (SI 2016 / 1101) as amended.
•
The Electromagnetic Compatibility Regulations 2016 (SI 2016 / 1091) as amended.
•
The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012 (SI 2012 / 3032) as amended.
Page 9
WEEE Compliance Statement
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
½
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
CSA Compliance Statement
CSA Group is a Nationally Recognised Testing Laboratory (NRTL) in the U.S. and an
Accredited Certification Organisation (ACO) by Standards Council of Canada (SCC) in
Canada. They are qualified to test to CSA Group (CSA), American National Standards
Institute (ANSI), American Society of Mechanical Engineers (ASME), American Society
for Testing and Materials (ASTM), American Society of Sanitary Engineers (ASSE),
National Sanitation Foundation (NSF), Underwriters Laboratories (UL) and other
standards writing bodies.
All PEAK products that are subject to the CSA directive are compliant with the CSA
marking requirement. Such products are marked with the “CSA” symbol (shown below)
in accordance with CSA directives.
Page 36
Supported Maintenance Plan
Infinity 5010 - 40 & 9010 - 40 series
Introduction
The following is a guide for maintenance of the Infinity 5010-40 & 9010-40 series Nitrogen
Generator as provided for by the Peak Service Plan.
This procedure is to be performed on an annual basis.
1. Check that the LC/MS is not in use and that it is OK to disconnect the Gas Supply.
Check that the Gas Demand is turned OFF.
2. Shut the Air Supply Valve and turn the Generator OFF.
3. Remove both the side Access Panels.
4. Carefully open the RAC filter drain allowing the generator to slowly de-pressurize.
Confirm that the gauges return to Zero. Any pressure gauge that does not return
to zero may be damaged and must be replaced.
5. Replace the RAC Filter Element and re-assemble the filter.
Page 37
6. Unscrew the top and bottom covers from the breathing air filter.
7. Replace the Breathing Air Filter Elements.
8. Re-assemble the breathing air filter.
9. Carefully open the Air Supply Valve and turn the Generator ON.
10. Switch the LC/MS gas demand ON.
Service Parts List
Service Parts List 5010-40 & 9010-40
Part Number
Description
3302283 (00-0041*)
RAC Filter Element
1
3302280 (00-0042*)
Coalescing Element for BA Filter
1
3302281 (00-0043*)
Active Carbon Element for BA Filter
1
Quantity
Element part numbers with (*) are obsolete the 330228X part number should be ordered
Page 38
Supported Maintenance Plan
Infinity 5050 - 80 & 9050 - 80
Introduction
The following is a guide for maintenance of the Infinity 5050 -80 & 9050-80 Nitrogen
Generator as provided for by the Peak Service Plan.
This procedure is to be performed on an annual basis.
1. Check that the LC/MS is not in use and that it is OK to disconnect the Gas Supply.
Check that the Gas Demand is turned OFF.
2. Shut the Air Supply Valve and turn the Generator OFF.
3. Remove both the side Access Panels.
4. Carefully open the RAC filter drain allowing the generator to slowly de-pressurize.
Confirm that the gauges return to Zero. Any pressure gauge that does not return
to zero maybe damaged and must be replaced.
5. Replace the RAC Filter Element and re-assemble the filter.
Page 39
6. Unscrew the top and bottom covers from the breathing air filter.
7. Replace the Breathing Air Filter Elements.
8. Re-assemble the breathing air filter.
9. Carefully open the Air Supply Valve and turn the Generator ON.
10. Switch the LC/MS gas demand ON.
Service Parts List
Service Parts List 5050-80 & 9050-80
Part Number
Description
Quantity
3302283 (00-0041*)
RAC Filter Element
1
3302280 (00-0042*)
Coalescing Element for BA Filter
2
3302281 (00-0043*)
Active Carbon Element for BA Filter
2
Element part numbers with (*) are obsolete, the 330XXXX part number should be ordered.
Page 40
Page 41
Page 42
Page 43
2024