Account Menu
  • Log in
  • Contact us
  •  Dash
  • Search results
  •  Featured collections
  •  Recent
  •  Knowledge Base
 All resources
Product Range
By date

 Geographic search

 Advanced search


Log in

Username
Password


 Click here to apply for an account

 Click here if you have forgotten your password

 Use SSO to log in

View all results

Hydrogen Detector - User Manual 

Full screen preview

Resource tools

Original PDF File

1.4 MB Download
  •  Share
Resource details

Resource ID

154

Access

Open

Contributed by

Liam Couttie

Review date

03 May 19

Title

Hydrogen Detector - User Manual

Revision Number

4

Keywords

4

Product Range

Other

Company Brand

Peak Scientific

Public / Private

public

Reviewed on 3rd may 2017 - LC

Extracted text

<p><p>Hydrogen Detector User Manual<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/13<br><br> H² Detector User Manual<br><br> Contents<br> Change History How to use this Manual Introduction Warranties and Liabilities Safety Notices Symbols Safety Notice to Users Declaration of Conformity Environmental Declaration Technical Specification Environment Detector Inlets Default Configuration Electrical Requirements General Unpacking Installation Detector Environment General Dimensions Rear Connections Fittings Kit In Line Filter Connecting to the GC Tubing Lengths Electrical Connection Sensor Cartridge Installation Start-up Sequence IMPORT ANT DOCUMENTS Service Requirements Service Schedule Trouble Shooting 3 3 4 5 6 6 6 7 8 9 9 9 9 9 9 10 11 11 12 13 13 13 14 15 16 17 19 20 21 21 21<br><br> Page 2<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Change History<br> Rev.<br> 1 2 3 4<br><br> Comment<br> D.O.C. Altered Connection Image Altered GC Connection Info Added, Fittings Kit Additions<br><br> Name<br> Liam Couttie Liam Couttie Liam Couttie Liam Couttie<br><br> Date<br> 17/09/12 31/10/12 14/05/13 03/09/13<br><br> How to use this Manual<br> This manual is intended for end users and has been written so that it can either be read as a step by step guide to installation and usage or as a reference document where you can skip to the relevant information. Users of a hard copy version can refer to the contents page to find the relevant information. Users of the soft copy version can use the hyperlinks from the contents page as well as the hyperlinks between sections. Please review each of the following sections carefully. Thank you for selecting Peak Scientific to meet your Gas Detection needs, and should you require any further assistance or support please do not hesitate to contact Peak Scientific or Peak Partner from which you purchased your Detector.<br><br> Page 3<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Introduction<br> The Peak Scientific Hydrogen Detector is an extractive gas sampling system that draws a sample locally from your GC Oven to a sensor cartridge that is located inside the detector’s chassis. Our Hydrogen Detector is wall mountable and displays gas concentration, alarm, fault and status information via its backlit LCD and LEDs. A simple to use 4-button keypad located under the display provides the facility to set-up, review, operate and make changes to the detector’s configuration.<br><br> Page 4<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Warranties and Liabilities<br> 1. The Company warrants that it has title to the Goods. 2. Subject to the provisions of this clause the Company warrants that the Goods shall comply in all material respects with any specification referred to in the Order Confirmation (as the same may be amended) and shall, subject thereto, be free from defects in material and workmanship for the lesser of a period of twelve months from the date of delivery or thirteen months from the date of dispatch from the factory. 3. Save as provided in this clause and except where the Goods are sold to a person dealing as a consumer (within the meaning of the Unfair Contract Terms Act 1977) all warranties, conditions or other terms implied by statute or common law are hereby expressly excluded save to the extent they may not be lawfully excluded. When the Goods are sold to a consumer within the meaning of the Unfair Contract Terms Act 1977 their statutory rights are not affected by the provisions of this clause. 4. In the event of the Customer making a claim in respect of any defect in terms of clause 2 hereof the Customer must. 1. Reasonably satisfy the Company that the Goods have been properly installed, commissioned, stored, serviced and used and without prejudice to the generality of the foregoing that any defect is not the direct or indirect result of lack of repair and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or incorrect spare parts 2. Allow the company to inspect the Goods and/or any installation and any relevant packaging as and when reasonably required by the Company. 5. Subject to the Company being notified of any defect as is referred to in sub-clause 2 hereof within a reasonable time of it becoming apparent and subject always to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or repair the defective Goods or refund a proportionate part of the Price. The Company shall have no further liability to the Customer (save as mentioned in sub-clause 6 hereof). 6. The Company shall be liable to indemnify the Customer in respect of any claim for death or personal injury to any person in so far as such is attributable to the negligence or breach of duty of the Company or any failure by the Company to comply with the provisions of sub-clause 2 hereof.<br><br> 7. Save as provided in sub-clause 2 hereof the Company shall not be liable<br> in respect of any claim by the Customer for costs, damages, loss or expenses (whether direct, indirect, consequential or otherwise) or indemnity in any respect howsoever arising including, but not by way of limitation, liability arising in negligence (other than pursuant to clause 6 above) that may be suffered by the Customer or any third party.<br><br> Page 5<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Safety Notices<br> Symbols<br> This manual uses the following symbols to highlight specific areas important to the safe and proper use of the detector<br> A WARNING notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause personal injury or in the worst case death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood or met. A CAUTION notice denotes a hazard. It calls attention to an operating procedure, process or similar, which if not correctly performed or adhered to, could cause damage to the Detector or the Application. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met.<br><br> Caution, risk of electric shock. Ensure power to the Detector has been removed before proceeding.<br><br> Safety Notice to Users<br> These instructions must be read thoroughly and understood before installation and operation of your Peak Hydrogen Detector. Use of the Detector in a manner not specified by Peak Scientific MAY impair the SAFETY provided by the equipment. When handling, operating or carrying out any maintenance, personnel must employ safe engineering practices and observe all relevant local health and safety requirements and regulations. The attention of UK users is drawn to the Health and Safety at Work Act 1974, and the Institute of Electrical Engineers regulations. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment maybe impaired.<br><br> Page 6<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Declaration of Conformity<br> We of declare that: Peak Scientific Instruments Ltd. Fountain Crescent, Inchinnan. Renfrewshire PA4 9RE Hydrogen Detector Hydrogen Detector<br><br> Equipment Model<br><br> To which this declaration relates, is in conformity with the applicable EC Directives, harmonized standards, and other normative requirements.<br><br> •<br><br> EN 61010-1: 2010 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use. Part 1: General requirements.<br><br> Low Voltage Directive 2006/95/EC<br><br> •<br><br> EN 50270 : 2006 Electromagnetic compatibility – Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen.<br><br> Electromagnetic Compatibility Directive 2004/108/EC<br><br> All evaluation, testing and certification issued by: York EMC Services (2007) Ltd Donibristle Industrial Park Dunfermline Fife KY11 9HZ Signed By: Name: Position: Done at: Date: Chris Pugh Engineering Director Peak Scientific Instruments Ltd, Inchinnan, Scotland. 31 October 2012<br> st<br><br> Page 7<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Environmental Declaration<br> We of declare that: Peak Scientific Instruments Ltd. Fountain Crescent, Inchinnan. Renfrewshire PA4 9RE<br><br> Equipment Model<br><br> Hydrogen Detector Hydrogen Detector<br><br> Is fully compliant with the following Directives: 2002/96/EC WEEE (Waste of Electrical and Electronic Equipment) 2002/95/EC RoHS (Restriction of Hazardous Substances) Peak Scientific Instruments Ltd fully complies with its obligations towards the European WEEE (Waste of Electrical and Electronic Equipment) Directive 2002/96/EC. These obligations are being met within the B2B compliance group. Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to ensure that our products comply with the principles and requirements of the European RoHS (Restriction of Hazardous Substances) Directive 2002/95/EC. Similar directives in the United States and China, for example, have also been captured within this program. Where a specific certificate of compliance is required, this can be requested, on a product serial number basis, directly from Peak Scientific Instruments Ltd, by contacting us through our website on www.peakscientific.com Signed By: Name: Position: Done at: Date: Chris Pugh Engineering Director Peak Scientific Instruments Ltd, Inchinnan, Scotland. 29 August 2012<br> th<br><br> Page 8<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Technical Specification<br> Environment<br> Minimum operating ambient temperature Maximum operating ambient temperature Maximum relative humidity Minimum storage temperature* Maximum storage temperature* 0°C (40°F) 40°C (104°F) 90% Non-Condensing 0 C (40 F) 40 C (104 F)<br> o o o o<br><br> *NOTE – When taken out of storage the Detector should be allowed to acclimatize at room temperature for a minimum of 3 hours before operation.<br><br> Detector Inlets<br> Mass Flow Rate Transport time Ambient Point 500 cc/min(10in/H2O max pressure/vacuum) 2-30 seconds maximum In line air filter required (supplied)<br><br> Default Configuration<br> Current source with: 1.0mA Fault 2.0mA Inhibit 3.0mA Maintenance Fault 4.0 to 20.0mA Gas Reading (normal operation) 21mA Over range Toxic Gas Flammable Gas 100% Lower Typically 4 x Threshold Limit Explosive Limit Value (TLV) (LEL) Typically ½ TLV 10% LEL Typically 0.4 TLV 9% LEL<br><br> Oxygen 25% Volume (v/v) 5% v/v 0% v/v<br><br> Full Scale(FS) Lowest Alarm Level (LAL) Lower Detectable Level (LDL) Alarm 1 (Relay 1) Alarm 2 (Relay 2) Fault (Relay 3) Latching Pass Code<br><br> The LDL is the minimum level that is reliably distinguishable from zero. ½ TLV 10% LEL 23.5% v/v (rising) Normally de-energized, energizes on alarm. Contact Normally Open (NO), Closes on alarm. TLV 20% LEL 19.5% v/v (Falling) Normally De-energized, de-energizes on alarm. Contact Normally Open (NO), closes on alarm. Normally energized, de-energizes on fault. Contact normally open (NO). Instrument Fault only. Latching Alarm and fault relay DO NOT automatically reset when reading falls below alarm thresholds. Relays MUST be manually reset. No pass code set.<br><br> Electrical Requirements<br> The Detector has its power supplied by the Precision 500 generator<br><br> General<br> Detector dimensions in cm W x D x H Detector weight Shipping crate dimensions in cm W x D x H Shipping weight 6.3 x 16.2 x 20 (2.5” x 6.4” x 7.9”) 1.8 kg (3.9 lb.) 40 x 40 x 15 (15.7” x 15.7” x 5.9”) 3 kg (6.6 lb.)<br><br> Page 9<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Unpacking<br> Although Peak Scientific takes every precaution with safe transit and packaging, it is advisable to fully inspect the unit for any sign of transit damage. Check ‘SHOCKWATCH’ label for signs of rough handling prior to un-packing –<br><br> Any damage should be reported immediately to the carrier and Peak Scientific or the Peak Partner from where the unit was purchased. Please save the product packaging for storage or future shipment of the Detector. Note: Included with the Detector is a “Fittings Kit” containing the communication cable for connecting the detector to the generator also all the required fittings. Be careful not to discard these with the packaging.<br><br> Page 10<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Installation<br> Detector Environment<br> The Detector is designed for use indoor safe non- explosive atmospheres only. It should be installed at a suitable height adjacent to the Gas Chromatograph it is connected to. Please see the Tubing lengths section for further details on maximum distances from the GC for maximum performance of the detector. Performance of the Detector (like all sophisticated equipment) is affected by ambient conditions. Note should also be taken to the proximity of Air Conditioning outlets. These can sometimes give rise to “pockets” of air with high relative humidity. Operation of the unit within such a pocket could adversely affect its performance. Please refer to the drawing below for the general dimensions of the unit. Maximum Ambient Conditions: 40°C (dry bulb) 90%RH (Max) Non-Condensing<br><br> Location<br> The detector can be located on a flat surface or wall mounted for operation this will ensure that you can locate it within the maximum distance required for the unit to successfully monitor for Hydrogen leaks. The Peak Hydrogen Detector is supplied with a bracket to allow a simple way to mount the unit to a wall near the GC.<br><br> Use 2 x M4 Screws or equivalent (not supplied) for mounting the bracket to the wall. You will then be able to lower the detector unit onto the wall bracket. The wall mounting has been specially designed to allow greater serviceability by enabling the unit to be taken down off of the wall for service and maintenance work to be carried out, without having to remove the wall bracket.<br><br> Page 11<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> General Dimensions<br><br> The Detector must always be placed on a level surface. Failure to do so will affect the performance of the Detector.<br><br> Page 12<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Rear Connections<br> Fittings Kit<br> Supplied in the Fittings Kit are all the fittings required to connect the Hydrogen Detector to the Generator. The contents of the Fittings Kit are as follows: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Communications Cable In Line Filter Cartridge ¼” Push Fit Barbed Fitting ¼” OD x ⅛” THK Exhaust Tubing ¼” OD x 3/16” THK Input Tubing ⅛” OD Stainless Steel Tubing Bulkhead Reducer Fitting Tygon Filter Tubing Hex Key Hose Clips Wall Mounting Bracket Installation Guide– Hydrogen Detector User Manual CD– Hydrogen Detector ×1 ×4 x1 ×2 × 1.5m × 1.5m x 1m x1 x 1m x1 x2 x1 ×1 ×1<br><br> In Line Filter<br> The In Line filter should be fitted, as close to the instrument as possible, on the end of the tubing which is connected to the Input port at the rear of the Detector, as shown below.<br><br> ¼” Barbed Fitting<br><br> Input Tubing<br> Page 13<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> Hose Clamp Tygon Tubing Inlet Filter<br><br> H² Detector User Manual<br> Connecting to the GC<br> 1. First remove the plastic cover on the top of the GC.<br><br> 2. Locate the cut-out hole on the aluminium plate directly above the rear hole on the GC oven.<br><br> 3. Make a hole through the insulation material, through to the oven. The stainless steel tubing from the detector can now be pushed through the hole, and secured in place using more insulation material.<br><br> 4. Once the stainless steel tubing has been pushed through and secured, the end of the tubing should be aimed at the inlet of the GC column.<br><br> Page 14<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br><br> 5. Position the end of the tubing as close to the inlet as possible, without limiting access for column changes and inlet maintenance.<br><br> 6. The detector is now fully connected and will take samples continuously and both the detector and the H2 generator will sound an alarm if dangerous levels of Hydrogen are detected. The generator will then shut down.<br><br> Tubing Lengths<br> The length of the tubing which will be connected to the Input Port of the Detector is important and is determined by the Hydrogen cartridge used by the detector. Failure to follow these recommendations could lead to the Hydrogen Detector failing to operate efficiently. Inlet Sample Specifications: Maximum Tubing Length, m (ft.) Transport Time (Sec) Tubing OD, mm (in) Tubing ID, mm (in) 30 (100) 28 20 (66) 19 10 (33) 10 6.35 (0.25) 3.18 (0.125) 0 1<br><br> Page 15<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Electrical Connection<br> Connect the Detector to the Peak Scientific Precision 500 Generator using the communication cable provided. This unit is plugged, from the ‘In’ port at the rear on the detector, into the ‘H2 Detector’ port at the rear of the generator, as shown below. This connection will provide the detector unit with power and allows communication between the Precision 500 and the detector unit. The detector will take samples continuously and both the detector and the Precision 500 will alarm if dangerous levels of hydrogen are detected, the Precision 500 will then shut down. Multiple detectors can be connected to one Precision 500. If this is desired, connect the first detectors ‘Out’ port to the second detectors ‘In’ port, as illustrated below. Please take into consideration when working with multiple Hydrogen Detector Units that a minimum required distance between units is 82mm (3.23in). Precision 500 H2 Detector In Port Out Port H2 Detector Port<br><br> Page 16<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Sensor Cartridge Installation<br> The pre-calibrated smart sensor cartridges can easily be fitted or replaced as they simply plug into the detector without the need for any tools. The sensor cartridge is firmly held in place by two locking tabs. Some cartridges are shipped with a protective cap to shield them from contaminants during shipping. This cap must be removed before inserting the cartridge into the Detector unit, failure to do so may damage the transmitter. Switch the power switch on the terminal module to the ‘on’ position and the re fit the Sensor warranty is void if the sensor cartridge is opened by unauthorised user. *The cartridge has an ‘activate by’ date that must be adhered to.<br><br> Page 17<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> In a first-time start up, an F49 or F88 fault code may be displayed; there is no actual fault and the fault message can be cleared by depressing the “X” button for a few seconds. To properly activate the Detector with the cartridge for the first time: 1. 2. 3. 4. 5. When “ChAngE gAS” or “FIrSt CELL” scrolls on the display, hit the on “✓” the Detector front panel. When the “reboot” completes then press and hold the “X” to clear any latched fault(s). Confirm that the green LED is flashing. Confirm that the yellow and red LEDs are off. Confirm the display shows a concentration of zero (as appropriate).<br><br> The cartridge has now been accepted by the Detector as the correct type. If the above steps were not performed at initial start-up, the remove the cartridge and cycle power. Once the Detector has completed the “reboot” process, install the cartridge and repeat the steps above.<br><br> Page 18<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Start-up Sequence<br> CHECK: 1. Ensure power cable is correctly connected between the Hydrogen Generator and the Hydrogen Detector.<br><br> 2. Hydrogen Generator is turned on. 3. After applying power to the Peak Scientific Hydrogen Detector the unit will run go through a start-up test routine illuminating in sequence all LEDs, icons and digits of the display. The unit will then display the messages “WAIT” and “LOAD” as it checks for the cartridge data, typically less than 180 seconds. 4. When complete, the detector will enter normal monitoring mode indicated by the icon on the display cycling through three states (2 rings, 3 rings, 4 rings). The measured gas concentration will be shown on the display. The green LED will flash once every second indicating power and the sample flow rate indicator will be displayed. If monitoring is interrupted due to a fault, a test or calibration process or a user requested inhibit, the display will flash, please refer to the Troubleshooting section for guidance. (See Figure 1)<br><br> Figure 1: Normal Operation<br><br> Page 19<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> IMPORTANT DOCUMENTS Warranty Entitlement<br> To register your generator for your warranty entitlement, send the completed form to Peak Scientific by: • • • • Email Online Phone Fax<br> warranty@peakscientific.com http:/ /www.peakscientific.com/service-and-support/warranty_registration<br><br> +44 (0)141 530 4185 +44 (0)141 812 8200<br><br> PRODUCT WARRANTY REGISTRATION<br> COMPANY: ADDRESS: EMAIL ADDRESS: CONTACT NAME:<br><br> CITY/TOWN: POSTCODE: COUNTRY: TELEPHONE:<br><br> DETECTOR SERIAL NUMBER:<br><br> MODEL TYPE: INSTALLATION DATE (DD/MM/YYYY):<br><br> Important Please Note:<br> You have 1 month to register your Peak Scientific product from the date of shipment. If you wish to defer installation of your detector you must notify Peak Scientific within 1 month of the shipment date. This can be done by emailing warranty@peakscientific.com Once registered the warranty will be honoured for a period of 12 months after the installation date. For any generators that remain unregistered the warranty will begin from date of shipment. Thank you on behalf of Peak Scientific.<br><br> Page 20<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> Service Requirements<br> Service Schedule<br> Purchase Interval 12 months Component Detector Annual Service Kit Table 1: Annual Service Kit Part No. 08-9003 Qty. 1<br><br> Trouble Shooting<br> Fault Code M10 Over Range – A large concentration has been detected. The Detector requires an independent confirmation that the gas hazard has gone. M12 Cartridge Expires Soon – Cartridge is old and will expire soon. M13 Flow Error – Detector is no longer able to regulate flow (high or low flow condition). M14 Interferent Present – An interferent is degrading the ability of the Detector to detect gas. M15 Temperature Near Limit – Temperature within 2 Celsius of limit. Possible Solution • • Supply known clean air to the Detector, and clear this fault. Contact Peak Service Provider.<br><br> • • • • • • • • • •<br><br> Replace the cartridge with a new cartridge. Contact Peak Service Provider. Check filters and pump. Check pressure at inlet and outlet and assure they are within specification. Contact Peak Service Provider. Check application. Contect Peak Service Provider. Check installation environment. Contact Peak Service Provider. Check for background gas concentration, temperature or humidity fluctuations. Perform zero calibration. Replace cartridge. Contact Peak Service Provider. Resume monitoring or increase timeout value. Contact Peak Service Provider. Replace Cartridge. Contact Peak Service Provider. Replace Cartridge. Contact Peak Service Provider. Replace Cartridge. Contact Peak Service Provider. If temperature or humidity shocks exist, precondition the cartridge. Check background gas concentration. Replace Cartridge.<br><br> M16 Baseline Fault – Sensor baseline has drifted.<br><br> • • • • • • • • • • • •<br><br> M17 Inhibit Timeout – Transmitter has been in inhibit mode too long F40 Sensor Overdosed – Sensor has been exposed to high gas concentrations for long periods. F43 Cartridge expired – Cartridge is too old. F44 Cell Failure – Cartridge has failed reflex check. F45 Stabilisation Timeout – Cartridge has failed to stabilise.<br><br> • •<br><br> Page 21<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> H² Detector User Manual<br> • F46 Cartridge Analog Failure – Electronic Failure or gas concentration greater than full scale. F47 Cartridge Memory Invalid – Checksum Error. F48 Cartridge Absent – No communications. F49 Cartridge Wrong Type – Cartridge type found to be incorrect after boot-up. F80 Temperature Limits Exceeded – Temperature is outside limits. F81 Flow Fail – Flow Peak Scientific UK Fountain Crescent Inchinnan Business Park Inchinnan PA4 9RE Scotland, UK Tel: +44 (0)141 812 8100 Fax: +44 (0)141 812 8200 Peak Scientific Germany Herriotstrasse 1 60528 Frankfurt<br><br> Peak Scientific North America 19 Sterling Road Suite #1 Billerica, MA 01862 USA Tel: +1 866 647 1649 Fax: +1 978 608 9503 Peak Scientific China Room 606 Building 1 Lane 2277 Zuchongzhi Road Pudong New Area Shanghai 201203, China Tel: +86 21 5079 1190 Fax: +86 21 5079 1191 Peak Scientific Brazil Peak Scientific Brasil Av. Quieroz Filho 1700 – torre Sunny-Conj. 602 São Paulo SP Brasil Tel: +1 866 647 1649<br><br> Peak Scientific India 202, Amsri Shamira Old Lancer Line Opp. St. Mary’s Degree College S.D. Road Secunderabad 500 025, India Tel: +91 40 2780 0663 Fax: +91 40 2780 0663 Peak Scientific Mexico Solon 352 Col. Los Morales Polanco 11530 Mexico, D.F. Mexico Tel: Fax: +1 866 647 1649 +1 978 608 9503<br><br> Peak Scientific Africa PO Box 478 Somerset Mall 7137 South Africa Tel: +27 (0)2185 16542 Fax: +27 (0)8654 64473 Peak Scientific Australia PO Box 65 Belmont Victoria 3216 Australia Tel: +61 1300 965 352<br><br> Germany Tel: +49 (0)69 677 33 490 Fax: +49 (0)69 677 33 200 Peak Scientific Taiwan 4F.-6, No.736 Zhongzheng Rd. Zhonghe Dist. New Taipei City Tel: +886 2 8226 2383 Fax: +886 2 8226 9499<br><br> Peak Scientific Japan K.K. 2-7-56, 2F Fuji Building 28 Kita Aoyama, Minato-Ku Tokyo, Japan 107-0061 Tel: +81 3-6864-0468<br><br> Peak Scientific Singapore 3 Science Park Drive #03-14 The Franklin Science Park Drive 1 Singapore, 118223 Tel: +65-6777 1966 Fax: +65-6777 1978<br><br> 2013 © Peak Scientific – Rev 4 – 03/09/1<br><br> </p></p>

Comments
Search for similar resources