Account Menu
  • Log in
  • Contact us
  •  Dash
  • Search results
  •  Featured collections
  •  Recent
  •  Knowledge Base
 All resources
Product Range
By date

 Geographic search

 Advanced search


Log in

Username
Password


 Click here to apply for an account

 Click here if you have forgotten your password

 Use SSO to log in

View all results

Corona 1010 - User Manual 

Full screen preview

Resource tools

Original PDF File

1.2 MB Download
  •  Share
Resource details

Resource ID

153

Access

Open

Contributed by

Debora LU

Updated date

30 September 19

Review date

30 September 20

Title

Corona 1010 - User Manual

Revision Number

4

Revision Details

Name Update - LC

Keywords

11

Product Range

Other

Company Brand

Peak Scientific

Public / Private

public

Reviewed on 3rd may 2017 - LC

Extracted text

<p>Corona 1010<br> User Manual<br><br> Corona 1010 User Manual Rev 4 RSID 153 PN UM-0016 EN 02/09/19<br><br> Contents<br> Contents 2<br> Change History <br> 3<br> How to use this Manual <br> 3<br> Introduction 4<br> Warranties and Liabilities <br> 5<br> Safety Notices <br> 6<br> Symbols 6<br> Safety Notice to Users <br> 6<br> Declaration of Conformity <br> 7<br> Environmental Declaration <br> 8<br> Technical Specification <br> 9<br> Corona Nitrogen 1010 <br> 9<br> Unpacking 10<br> Fittings Kit Contents <br> 11<br> Unpacking Instructions <br> 11<br> Installation 12<br> Generator Environment <br> 12<br> Generator Overview <br> 13<br> Corona Nitrogen 1010 General Dimensions <br> 13<br> Corona Nitrogen 1010 Rear Connections <br> 14<br> Electrical Connection <br> 15<br> Air Purity <br> 16<br> Class 1 Particulate <br> 16<br> Class 4 Water <br> 16<br> Class 1 Oil <br> 16<br> Start-Up Sequence <br> 17<br> On Demand Gas <br> 17<br> Unusual Operation <br> 17<br> Connecting to the application <br> 18<br> Tubing Lengths <br> 18<br> Service Requirements <br> 19<br> Service Schedule <br> 19<br> Peak Protected <br> 20<br> Cleaning 21<br> Troubleshooting 22<br><br> Page 2<br><br> Change History<br> Rev<br><br> Comment<br><br> Name<br><br> Date<br><br> 2<br><br> Updated Service Kit Info<br><br> L. Couttie<br><br> 19/02/2018<br><br> 3<br><br> Power Value Update<br><br> L. Couttie<br><br> 26/08/2019<br><br> 4<br><br> Name Update<br><br> L. Couttie<br><br> 02/09/2019<br><br> How to use this Manual<br> This manual is intended for end users and has been written as a reference document<br> where you can skip to the relevant information.<br> Users can refer to the contents page to find the relevant information.<br> Please review each of the following sections carefully.<br> Thank you for selecting Peak Scientific to meet your gas generation needs, and should<br> you require any further assistance or support please do not hesitate to contact Peak<br> Scientific or the Peak Partner from which you purchased your generator.<br><br> Page 3<br><br> Introduction<br> The Corona 1010 has been developed by Peak Scientific in conjunction with Thermo<br> Fisher Scientific to supply pure Nitrogen to their Charged Aerosol Detectors (CAD).<br> The Corona 1010 generates gas at the right flow, pressures and purities required by the<br> Charge Aerosol Detector and has been fully tested and approved by Thermo.<br> Peak Scientific offers a compact, stackable solution with their Corona products, but<br> also with a Corona Veo CAD itself.<br> Other features include:<br> • Generates Nitrogen on demand from compressed air.<br> • Effective and reliable membrane technology.<br> • Minimum maintenance with only a filter change per annum.<br> • Small and Stackable.<br> To ensure these generator models meet our high expectations with regards to reliability<br> and performance, we have tested them extensively at our manufacturing plant and with<br> end users around the world to ensure reliability and longevity of the system.<br><br> Page 4<br><br> Warranties and Liabilities<br> 1. The Company warrants that it has title to the Goods.<br> 2. Subject to the provisions of this clause the Company warrants that the Goods <br> shall comply in all material respects with any specification referred to in the Order <br> Confirmation (as the same may be amended) and shall, subject thereto, be free <br> from defects in material and workmanship for the lesser of a period of twelve <br> months from the date of delivery or thirteen months from the date of dispatch <br> from the factory.<br> 3. Save as provided in this clause and except where the Goods are sold to a person <br> dealing as a consumer (within the meaning of the Unfair Contract Terms Act <br> 1977) all warranties, conditions or other terms implied by statute or common <br> law are hereby expressly excluded save to the extent they may not be lawfully<br> excluded. When the Goods are sold to a consumer within the meaning of the Unfair<br> Contract Terms Act 1977 their statutory rights are not affected by the provisions of<br> this clause.<br> 4. In the event of the Customer making a claim in respect of any defect in terms of <br> clause 2 hereof the Customer must.<br> 1. Reasonably satisfy the Company that the Goods have been properly installed,<br> commissioned, stored, serviced and used and without prejudice to the generality<br> of the foregoing that any defect is not the direct or indirect result of lack of repair<br> and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or<br> incorrect spare parts<br> 2. Allow the company to inspect the Goods and/or any installation and any relevant<br> packaging as and when reasonably required by the Company.<br> 5. Subject to the Company being notified of any defect as is referred to in sub- <br> clause 2 hereof within a reasonable time of it becoming apparent and subject always<br> to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or<br> repair the defective Goods or refund a proportionate part of the Price. The Company<br> shall have no further liability to the Customer (save as mentioned in sub-clause 6<br> hereof).<br> 6. The Company shall be liable to indemnify the Customer in respect of any claim<br> for death or personal injury to any person in so far as such is attributable to the<br> negligence or breach of duty of the Company or any failure by the Company to<br> comply with the provisions of sub-clause 2 hereof.<br> 7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect<br> of any claim by the Customer for costs, damages, loss or expenses (whether direct,<br> indirect, consequential or otherwise) or indemnity in any respect howsoever arising<br> including, but not by way of limitation, liability arising in negligence (other than<br> pursuant to clause 6 above) that may be suffered by the Customer or any third<br> party.<br><br> Page 5<br><br> Safety Notices<br> Peak Scientific Instruments cannot anticipate every possible circumstance which may<br> represent a potential hazard. The warnings detailed within this manual refer to the most<br> likely potential hazards, but by definition cannot be all inclusive. If the user employs<br> an operating procedure, item of equipment or a method of working which is not<br> specifically recommended by Peak Scientific, the user must ensure that the equipment<br> will not be damaged or become hazardous to persons or property.<br><br> Symbols<br> This manual uses the following symbols to highlight specific areas important to the safe<br> and proper use of the generator.<br><br> WARNING<br><br> A WARNING notice denotes a hazard. It calls attention to an operating procedure,<br> process or similar, which if not correctly performed or adhered to, could cause<br> personal injury or in the worst case death. Do not proceed beyond a WARNING<br> notice until the indicated conditions are fully understood or met.<br><br> CAUTION<br><br> A CAUTION notice denotes a hazard. It calls attention to an operating procedure,<br> process or similar, which if not correctly performed or adhered to, could cause<br> damage to the generator or the application. Do not proceed beyond a CAUTION<br> notice until the indicated conditions are fully understood or met.<br> Caution, risk of electric shock. Ensure power to the generator has been removed<br> before proceeding.<br><br> Safety Notice to Users<br><br> WARNING<br><br> WARNING<br><br> These instructions must be read thoroughly and understood before<br> installation and operation of your Peak Generator. Use of the generator<br> in a manner not specified by Peak Scientific MAY impair the SAFETY<br> provided by the equipment.<br> When handling, operating or carrying out any maintenance, personnel<br> must employ safe engineering practices and observe all relevant local<br> health and safety requirements and regulations. The attention of UK<br> users is drawn to the Health and Safety at Work Act 1974, and the<br> Institute of Electrical Engineers regulations.<br> If the equipment is used in a manner not specified by the manufacturer,<br> the protection provided by the equipment maybe impaired.<br><br> WARNING<br><br> Page 6<br><br> Declaration of Conformity<br> We <br><br> Peak Scientific Instruments Ltd.<br><br> Of <br><br> Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE<br><br> Declare that:<br> Equipment: Nitrogen Generator<br> Models: Corona 1010<br><br> To which this declaration relates, is in conformity with the applicable EC directives,<br> harmonized standards, and other normative requirements.<br> • Low Voltage Directive 2014/35/EU<br> EN 61010-1: 2010 Electrical Equipment for measurement, control and laboratory use.<br> • Electromagnetic Compatibility Directive 2014/30/EU<br> EN 61326-1: 2013 Electrical Equipment for measurement, control and laboratory use.<br> • FCC47 CFR Part 15 Class B<br> Unintentional radiators; Conductec and Radiated emissions limits.<br> All evaluation, testing and certification issued by:<br><br><br> York EMC Services Ltd. <br><br><br><br> Earls Road, Grangemouth Technology Park <br><br> Grangemouth <br><br><br> KY11 9HZ<br><br> Signed: Name: Chris Pugh<br> Date: <br><br> Page 7<br><br> 02/09/2016 <br><br> Position: <br><br> Engineering & Operations Director<br><br> Environmental Declaration<br> We <br><br> Peak Scientific Instruments Ltd.<br><br> Of <br><br> Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE<br><br> Declare that:<br> Equipment: Nitrogen Generator<br> Models: Corona 1010<br> Is fully compliant with the following Directives<br> • 2012/19/EU <br><br> WEEE (Waste of Electrical and Electronic Equipment)<br><br> • 2011/65/EU <br><br> RoHS2 (Restriction of Hazardous Substance)<br><br> Peak Scientific Instruments Ltd fully complies with its obligations towards the European<br> WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These<br> obligations are being met within the B2B compliance group.<br> Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to<br> ensure that our products comply with the principles and requirements of the European<br> recast RoHS2 (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar<br> directives in the United States and China, for example, have also been captured within<br> this program.<br> Where a specific certificate of compliance is required, this can be requested, on<br> a product serial number basis, directly from Peak Scientific Instruments Ltd, by<br> contacting us through our website on www.peakscientific.com<br> Signed: Name: Chris Pugh<br> Date: <br><br> Page 8<br><br> 02/09/2016 <br><br> Position: <br><br> Engineering & Operations Director<br><br> Technical Specification<br> Corona 1010<br> Environment<br> Minimum Operating Ambient Temperature<br> Maximum Operating Ambient Temperature<br> Maximum Altitude<br> Maximum Relative Humidity<br> Minimum Storage Temperature*<br> Maximum Storage Temperature*<br><br> 5°C (41°F)<br> 35°C (95°F)<br> 2000 m<br> 80% Non-Condensing<br> -20°C (-4°F)<br> 60°C (140°F)<br><br> Inlet Conditions<br> Inlet Air Pressure Min-Max<br> Minimum / Maximum Air Inlet Flow<br> Minimum Air Inlet Quality<br> Particles<br><br> 7.6-8.9 bar (110-130 psi)<br> 30 l/min<br> ISO 8573-1:2010 Class[1.4.1]<br> <0.01µm<br><br> Generator Outlets<br> Minimum / Maximum Gas Output Pressure<br> Minimum / Maximum Outlet Flow Rate<br> Start-up time<br> Purity<br> Particles<br> Phthalates<br> Suspended Liquids<br> Gas Outlets<br> Pressure Gauges<br> Start-Up Time For Purity<br><br> 5.5 bar (80 psi)<br> 5 l/min<br> 5 minutes<br> <2% O2<br> <0.01µm<br> NONE<br> NONE<br> 1<br> 1<br> 5 mins<br><br> Electrical Requirements<br> Voltage<br> Frequency<br> Current<br> Input Connection<br> Power Cord (Supplied)<br> Pollution Degree<br> Insulation Category<br><br> 100-230v<br> 50/60 Hz<br> 0.10A<br> C14 Plug<br> C13 Socket to Local Connection<br> 2<br> II<br><br> General<br> Dimensions cm (inches) WxDxH<br> Generator Weight Kg (lbs)<br> Shipping Weight Kg (lbs)<br> Page 9<br><br> 41.6 (16.3) x 54.0 (21.2) x 15.6 (6.14)<br> 12 (26.4)<br> 34 (74.9)<br><br> Unpacking<br> Although Peak Scientific takes every precaution with safe transit and packaging, it is<br> advisable to fully inspect the unit for any sign of transit damage.<br> Check ‘SHOCKWATCH’ and ‘TIP-N-TELL’ labels for signs of rough handling prior to<br> unpacking.<br><br> Any damage should be reported immediately to the carrier and Peak Scientific or the<br> Peak Partner from where the unit was purchased.<br> Follow the unpacking instructions posted on the side of the crate. It will require two<br> people to remove the unit from the shipping crate and to manoeuvre the generator<br> onto the bench.<br> Please save the product packaging for storage or future shipment of the generator.<br> Note: Included with the generator is a “Fittings Kit” containing mains power leads for<br> UK, EU & US and also all the required fittings and warranty registration card. Be careful<br> not to discard these with the packaging. <br><br> Page 10<br><br> Fittings Kit Contents<br> Supplied in the Fittings Kit are all the fittings required to connect the generator to the<br> application. The contents of the Fittings Kit are as follows:<br> 1. Teflon Tubing x 3m <br> 2. ¼” Compression Fitting x 1<br> 3. UK Mains Power Cable x 1<br> 4. EU Mains Power Cable x 1<br> 5. US Mains Power Cable 110v <br><br> x1<br><br> 6. US Mains Power Cable 230v <br><br> x1<br><br> All of the generators output ports are located on the output panel at the rear of the<br> unit.<br><br> Unpacking Instructions<br> The unit weight constitutes a two person lift and as such, safe lifting practices should<br> be employed; do not attempt to lift on your own, as you will significantly increase the<br> chance of injury & damage to yourself and others around you.<br> 1. Remove the plastic banding and remove the cardboard lid and sleeve.<br> 2. Next, with someone on either side of the unit, position your hands underneath the<br> unit ready to lift.<br> 3. Ensuring your knees are bent and your back is straight, lift the unit to the desired<br> location. <br><br> Page 11<br><br> Installation<br> Generator Environment<br> The generator is designed for indoor use only. It should be installed adjacent to<br> the application(s) it is supplying. If this is not convenient then the unit can be sited<br> elsewhere, however, consideration should be made of the lengths of pipe runs as<br> pressure drops can result from extended runs of pipe.<br> The performance of the generator (like all sophisticated equipment) is affected by<br> ambient conditions. Note should also be taken to the proximity of Air Conditioning<br> outlets. These can sometimes give rise to “pockets” of air with high relative humidity.<br> Operation of the unit within such a pocket could adversely affect its performance.<br> Consideration should also be given to the air flow around the unit. It is recommended<br> that an air gap of 75mm (3”) should be maintained down both sides and at the rear of<br> the unit. Please refer to the drawing below for the general dimensions of the unit.<br> Minimum Operating Ambient Temperature: <br><br> 5 °C (41 °F)<br><br> Maximum Operating Ambient Temperature: <br><br> 35 °C (95 °F)<br><br> Page 12<br><br> Generator Overview<br> Corona 1010 General Dimensions<br><br> 416 mm / 16.3”<br><br> 540 mm / 21.2”<br><br> 156 mm / 6.14"<br> The generator must always be placed on a flat, level surface. Failure to<br> do so will affect the performance of the generator.<br> WARNING<br><br> Page 13<br><br> Corona 1010 Rear Connections<br><br> ¼" Compression Fitting<br> ¼" Compression Fitting<br><br> Mains Cable<br><br> Page 14<br><br> Electrical Connection<br> Connect the generator to an appropriate 100-230v single-phase supply, refer to the<br> generator serial plate for input specification and ensure your supply matches the<br> requirements.<br> If the appropriate power cord is not supplied; a new plug, rated to at least 12 amps, can<br> be fitted by a qualified electrician.<br><br> WARNING<br><br> This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE<br> EARTHED. Before connecting the unit to the mains supply, please<br> check that your electrical supply falls within the specified range, see<br> below.<br><br> EARTH/GROUND (E):- <br><br> Green & Yellow or <br><br> Green<br><br> LIVE (L):- <br><br> Brown <br><br> or <br><br> Black<br><br> Neutral (N):- <br><br> Blue <br><br> or <br><br> White<br><br><br><br> Electrical requirements are 100-230v nominal +/- 10% depending on chosen model.<br> However, running continuously at voltages outside this is not recommended. Extended<br> periods at extremes can have a detrimental effect on the operation and life of the<br> generator.<br> If the equipment is used in a manner not specified by the manufacturer,<br> the protection provided by the equipment maybe impaired.<br> WARNING<br><br> Page 15<br><br> Air Purity<br> The Corona 1010 generator should be connected to an air supply that, as a minimum,<br> meets ISO8753-1:2010 Class 1.4.1<br><br> Class 1 Particulate<br> In each cubic metre of compressed air, the particulate count should not exceed 20,000<br> particles in the 0.1 - 0.5 micron size range, 400 particles in the 0.5 - 1 micron range and<br> 10 particles in the 1 - 5 micron size range.<br><br> Class 4 Water<br> A pressure dew point (PDP) of +3°C or better is required and no liquid water is allowed.<br><br> Class 1 Oil<br> In each cubic metre of compressed air, not more than 0.01mg of oil is allowed. This is a<br> total level for liquid oil, oil aerosol and oil vapour.<br><br> Page 16<br><br> Start-Up Sequence<br> Switch the generator on using the power switch on the rear panel of the unit. The LEDs<br> on the front panel will illuminate YELLOW for the start-up period.<br><br> YELLOW<br><br> The generator will provide Nitrogen almost instantaneously, assuming it has a suitable<br> air supply. The fascia illuminates GREEN to indicate adequate internal pressure has<br> been achieved.<br> GREEN<br><br><br><br> On Demand Gas<br> The generator will produce nitrogen on demand. If the application is operating<br> and requires a gas flow, the system it is connected to will supply this to suit the<br> requirements of the application. If the application requirement for gas stops, the system<br> will also stop. If the demand from the application starts again, the system will detect<br> the demand for gas and will automatically start again to suit the demand.<br><br> Unusual Operation<br> If at any time the generator begins to emit excessive noise or vibration, then it should<br> be switched off and you should contact Peak Scientific or the Peak Partner from which<br> the generator has been purchased.<br><br> Page 17<br><br> Connecting to the application<br> Once the LEDs have turned green, the generator is ready to be connected to the<br> application(s).<br> The pressure in the internal storage tanks must be allowed to dissipate<br> before connecting the generator to the application(s)<br> CAUTION<br><br> Attach the ¼” compression fitting to the outlet of the generator. Using suitable ¼”<br> tubing, and connect the outlet of the generator to the inlet on the application.<br> Please refer to the Tubing Lengths section, to ensure correct tubing is being used.<br><br> CAUTION<br><br> Once the tubing is connected to the application, please ensure that it<br> is thoroughly checked for being leak-tight. Even the slightest leak in<br> the gas supply between the generator and the application can lead to<br> a reduction in efficiency.<br><br> Tubing Lengths<br><br> CAUTION<br><br><br><br> The diameter of the tubing which will be connected to the gas outlet is<br> important and is determined by the length of tubing required. Failure<br> to follow these recommendations could lead to pressure between<br> generator and application.<br><br> < 10 meters: <br><br> Use ¼”/3⁄16” (¼” O/D, 3⁄16” I/D) P.T.F.E. tubing.<br><br><br> > 10 - 40 meters: Use 3⁄8”/ 5⁄16” (3⁄8” O/D, 5⁄16” I/D). Tubing and fittings not supplied <br> in the fittings kit.<br><br> > 40 metres: <br><br><br> Please contact Peak Scientific with the relevant distance and <br> we will calculate the flow resistance and the tubing size required.<br><br> A combination of ¼”/3⁄16” and 3⁄8”/5⁄16” tubing may be used to ensure that there is no large<br> diameter tubing within the lab (i.e. for the first 20 meters from the generator use 3⁄8”/5⁄16”<br> and the final 10 meters to the application use ¼”/3⁄16” tubing). Keep the connections and<br> bends to a minimum.<br><br> Page 18<br><br> Service Requirements<br> Service Schedule<br> Purchase Interval Component<br> 12 months<br><br> Page 19<br><br> Corona 1010 Annual Service Kit<br><br> Qty.<br><br> Visit<br><br> 1<br><br> www.peakscientific.com/<br> ordering<br><br> Peak Protected<br> With Peak Scientific you invest in not only a product but peace of mind. With a network of<br> certified Peak engineers stationed throughout the globe, Peak’s rapid response team are<br> never far away and our commitment is to keep your generator running day in, day out,<br> protecting your laboratory workflow.<br><br> [Peak Protected] can provide…<br><br> Installation<br><br> A dedicated Peak engineer will visit<br> your lab to install and setup your<br> generator<br><br> IQ/OQ<br><br> Certified assurance for applications<br> requiring documented qualification<br><br> Complete plan<br><br> Swift response by a Peak Service<br> Engineer within 72 hours & planned<br> preventative maintenance<br><br> Spares<br><br> Genuine Peak parts with express<br> delivery, ensuring optimal<br> performance and lifetime<br><br> Premium Protected<br><br> Guaranteed rapid on-site response<br> within 24 hours & planned<br> preventative maintenance<br><br> Technical Support Hotline<br><br> Around the clock support by phone<br> or online with our global technical<br> helpdesk<br><br> To find out more about protecting your investment visit: www.peakscientific.com/protected<br><br> Page 20<br><br> Cleaning<br> Clean the outside of the generator only using warm soapy water and a clean damp<br> cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.<br> Cleaning should only be undertaken with the power switched off and<br> the power cord removed from the rear of the generator.<br><br> CAUTION<br><br> Under no circumstances should any solvents or abrasive cleaning<br> solutions be used as these can contain fumes that could be harmful to<br> the generator.<br> Care should be taken with Leak Detections Liquids.<br><br> CAUTION<br><br> Page 21<br><br> Troubleshooting<br> Problem<br><br> Possible Solution<br> • Ensure power cord is plugged into the<br> generator and that the power socket is<br> turned on.<br><br> The generator will not switch on and the<br> power switch does not illuminate.<br><br> • Check the fuse in the power cord plug.<br><br> The fascia LED’s have not illuminated but the<br> power switch is illuminated.<br><br> • Contact your service provider.<br><br> The instrument is reporting low pressure.<br><br> • Contact your service provider.<br><br> • Check for leaks between the generator<br> and instrument.<br> • Contact your service provider.<br><br> The fascia Yellow illumination does not<br> change to green.<br><br> Page 22<br><br> • Check the air supply pressure to the<br> generator.<br> • Contact your service provider.<br><br> Go Online or Complete and Return<br> We know that registering any of your recently purchased products is not the<br> first thing on your mind- but it is very important to both of us. Not all warranties<br> are alike and Peak Scientific stand out against other gas suppliers as we offer a<br> comprehensive, quick response, on-site warranty. This means that in the very<br> unlikely case that your gas generator develops a fault we have rapid support<br> teams on-hand around the world who are able to come to your lab and get you<br> back up and running in no time.<br> Register for your comprehensive 12 month on-site warranty with ease online at<br> www.peakscientific.com/protected.<br> Alternatively, you can send the completed form to Peak Scientific by post or<br> email at warranty@peakscientific.com.<br><br> Go Online or Complete and Return<br> You can register for your FREE 12 month Warranty with ease online at<br> www.peakscientific/protected.<br> Alternatively, you can send the completed form to Peak Scientific by post or<br> email at warranty@peakscientific.com.<br><br> Product Warranty Registration<br> Contact name<br> Email address<br> Company<br> Address<br> City/town<br> Postcode<br> Country<br> Telephone<br> Generator serial #<br> Model type<br> Installation date<br> Do you still use an<br> alternative gas solution i.e.<br> cylinders or bulk liquid?<br><br> Yes<br><br> What gas requirements do<br> you have in your lab?<br><br> Hydrogen<br><br> No<br><br> Nitrogen<br><br> Zero Air<br><br> Extend your cover with<br> Peak Scientific offer comprehensive gas generator after sales support packages.<br> Peak [Protected] aftercare support can guarantee an on-site response within<br> 72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time<br> fix rate. See our enclosed Peak [Protected] leaflet for further information.<br> Important!<br> You have 1 month to register your Peak Scientific product from the date of installation. Once registered<br> the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your<br> generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com.<br> For generators that remain unregistered after 1 month from the shipment date, the warranty will be<br> considered active from the date of factory dispatch.<br> * Complete Plan only<br><br> <br> <br> <br> <br><br> Important!<br> You have 1 month to register your Peak Scientific product from the date of<br> installation. Once registered the warranty will be honoured for a period of 12<br> months. If you wish to defer the installation of your generator, you must notify<br> Peak Scientific immediately by emailing warranty@peakscientific.com. For<br> generators that remain unregistered after 1 month from the shipment date, the<br> warranty will be considered active from the date of factory dispatch.<br> Page 23<br><br> Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries<br> across every continent around the world. This allows us to provide an industry-leading rapid response<br> service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top<br> priority.<br> To discuss Peak Protected generator cover and payment options speak to your local Peak<br> Representative or for further information contact: protected@peakscientific.com<br><br> Peak Scientific<br> Fountain Crescent<br> Inchinnan Business Park<br> Inchinnan<br> PA4 9RE<br> Scotland, UK<br> Tel: +44 141 812 8100<br> Fax: +44 141 812 8200<br> For further information on any of our<br> generator products please contact<br> marketing@peakscientific.com<br> Corona 1010 User Manual Rev 4 RSID 153 PN UM-0016 EN 02/09/19<br><br></p>

Comments
Search for similar resources