Account Menu
  • Log in
  • Contact us
  •  Dash
  • Search results
  •  Featured collections
  •  Recent
  •  Knowledge Base
 All resources
Product Range
By date

 Geographic search

 Advanced search


Log in

Username
Password


 Click here to apply for an account

 Click here if you have forgotten your password

 Use SSO to log in

View all results

Genius 3030 & 3031 - User Manual 

Full screen preview

Resource tools

Original PDF File

1.4 MB Download
  •  Share
Resource details

Resource ID

128

Access

Open

Contributed by

Debora LU

Updated date

06 March 19

Review date

06 March 20

Title

Genius 3030 & 3031 - User Manual

Revision Number

3

Keywords

Genius, 3030, 3031, User, Manual

Product Range

Genius

Company Brand

Peak Scientific

Public / Private

public

Reviewed on 3rd may 2017 - LC

Extracted text

<p>Genius 3030 & 3031<br> User Manual<br><br> Genius3030-3031 User Manual Rev 3 RSID 128 PN UM-0005 06/03/19<br><br> Contents<br> Change History <br> 3<br> How to use this Manual <br> 3<br> Introduction 4<br> Warranties and Liabilities <br> 5<br> Safety Notices <br> 6<br> Declaration of Conformity <br> 7<br> Environmental Declaration <br> 8<br> Technical Specification <br> 9<br> Unpacking 11<br> Installation 13<br> Generator Overview <br> 14<br> Electrical Connection <br> 16<br> Start-Up Sequence <br> 17<br> Normal Operation <br> 17<br> On Demand Gas <br> 17<br> Generator Cycling <br> 18<br> Unusual Operation <br> 18<br> Connecting to the application <br> 19<br> Service Requirements <br> 20<br> Peak Protected <br> 22<br> Cleaning 23<br> Troubleshooting 24<br><br> Page 2<br><br> Change History<br> Rev<br><br> Comment<br><br> Name<br><br> Date<br><br> 1<br><br> Initial Release<br><br> L. Couttie<br><br> 06/04/2015<br><br> 2<br><br> Content Update<br><br> L. Couttie<br><br> 04/01/2017<br><br> 3<br><br> Indication of Fault Correction<br><br> L. Couttie<br><br> 06/03/2019<br><br> How to use this Manual<br> This manual is intended for end users and has been written as a reference document<br> where you can skip to the relevant information.<br> Users can refer to the contents page to find the relevant information.<br> Please review each of the following sections carefully.<br> Thank you for selecting Peak Scientific to meet your gas generation needs, and should<br> you require any further assistance or support please do not hesitate to contact Peak<br> Scientific or the Peak Partner from which you purchased your generator.<br><br> Page 3<br><br> Introduction<br> The Genius 3030 & 3031 have been developed to provide a supply of nitrogen gas<br> and dry air. We’ve built them with internal air compressors as standard, removing the<br> reliance upon an in-house air supply.<br> The Genius 3030 combines two individual systems in one cabinet, with both systems<br> supplying a single source of nitrogen gas as well as two independent suplies of clean<br> dry air. This allows two mass spectrometers to be supplied by one single Peak Scientific<br> gas generator.<br> The Genius 3031 provides a source of nitrogen gas as well as two independent supplies<br> of clean dry air.<br> These model provide a source of nitrogen gas and dry air with other features including:<br> • Quiet in operation – Insulated compressor compartment for minimum disruption<br> • Cool – Minimal heat build-up in the lab<br> • Intelligent – High duty service indicator<br> • Mobile – Flexibility to position the generator where required<br> • Simple installation – Generator designed as a plug and play system<br> • Economical – More cost effective than any other gas supply method<br> • Convenient – Gas on demand, no hazards, no need to worry about running out of<br> gas<br> The Genius 3030 & 3031 are based on proven technology, and selectively remove<br> oxygen, moisture and other gases to leave clean, dry, phthalate free nitrogen and dry<br> air. Internal air compressors make these units independent from in-house air supplies<br> and fitted castors allow the user to easily position the units in the lab.<br> To ensure these Generator models meet our high expectations with regards to reliability<br> and performance, we have tested them extensively at our manufacturing plant and with<br> end users around the world to ensure reliability and longevity of the system.<br><br> Page 4<br><br> Warranties and Liabilities<br> 1. The Company warrants that it has title to the Goods.<br> 2. Subject to the provisions of this clause the Company warrants that the Goods <br> shall comply in all material respects with any specification referred to in the Order <br> Confirmation (as the same may be amended) and shall, subject thereto, be free <br> from defects in material and workmanship for the lesser of a period of twelve <br> months from the date of delivery or thirteen months from the date of dispatch <br> from the factory.<br> 3. Save as provided in this clause and except where the Goods are sold to a person <br> dealing as a consumer (within the meaning of the Unfair Contract Terms Act <br> 1977) all warranties, conditions or other terms implied by statute or common <br> law are hereby expressly excluded save to the extent they may not be lawfully<br> excluded. When the Goods are sold to a consumer within the meaning of the Unfair<br> Contract Terms Act 1977 their statutory rights are not affected by the provisions of<br> this clause.<br> 4. In the event of the Customer making a claim in respect of any defect in terms of <br> clause 2 hereof the Customer must.<br> 1. Reasonably satisfy the Company that the Goods have been properly installed,<br> commissioned, stored, serviced and used and without prejudice to the generality<br> of the foregoing that any defect is not the direct or indirect result of lack of repair<br> and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or<br> incorrect spare parts<br> 2. Allow the company to inspect the Goods and/or any installation and any relevant<br> packaging as and when reasonably required by the Company.<br> 5. Subject to the Company being notified of any defect as is referred to in sub- <br> clause 2 hereof within a reasonable time of it becoming apparent and subject always<br> to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or<br> repair the defective Goods or refund a proportionate part of the Price. The Company<br> shall have no further liability to the Customer (save as mentioned in sub-clause 6<br> hereof).<br> 6. The Company shall be liable to indemnify the Customer in respect of any claim<br> for death or personal injury to any person in so far as such is attributable to the<br> negligence or breach of duty of the Company or any failure by the Company to<br> comply with the provisions of sub-clause 2 hereof.<br> 7. Save as provided in sub-clause 2 hereof the Company shall not be liable in respect<br> of any claim by the Customer for costs, damages, loss or expenses (whether direct,<br> indirect, consequential or otherwise) or indemnity in any respect howsoever arising<br> including, but not by way of limitation, liability arising in negligence (other than<br> pursuant to clause 6 above) that may be suffered by the Customer or any third<br> party.<br><br> Page 5<br><br> Safety Notices<br> Peak Scientific Instruments cannot anticipate every possible circumstance which may<br> represent a potential hazard. The warnings detailed within this manual refer to the most<br> likely potential hazards, but by definition cannot be all inclusive. If the user employs<br> an operating procedure, item of equipment or a method of working which is not<br> specifically recommended by Peak Scientific, the user must ensure that the equipment<br> will not be damaged or become hazardous to persons or property.<br><br> Symbols<br> This manual uses the following symbols to highlight specific areas important to the safe<br> and proper use of the generator.<br><br> WARNING<br><br> A WARNING notice denotes a hazard. It calls attention to an operating procedure,<br> process or similar, which if not correctly performed or adhered to, could cause<br> personal injury or in the worst case death. Do not proceed beyond a WARNING<br> notice until the indicated conditions are fully understood or met.<br><br> CAUTION<br><br> A CAUTION notice denotes a hazard. It calls attention to an operating procedure,<br> process or similar, which if not correctly performed or adhered to, could cause<br> damage to the generator or the application. Do not proceed beyond a CAUTION<br> notice until the indicated conditions are fully understood or met.<br> Caution, risk of electric shock. Ensure power to the generator has been removed<br> before proceeding.<br><br> Safety Notice to Users<br><br> WARNING<br><br> WARNING<br><br> These instructions must be read thoroughly and understood before<br> installation and operation of your Peak Generator. Use of the generator<br> in a manner not specified by Peak Scientific MAY impair the SAFETY<br> provided by the equipment.<br> When handling, operating or carrying out any maintenance, personnel<br> must employ safe engineering practices and observe all relevant local<br> health and safety requirements and regulations. The attention of UK<br> users is drawn to the Health and Safety at Work Act 1974, and the<br> Institute of Electrical Engineers regulations.<br> If the equipment is used in a manner not specified by the manufacturer,<br> the protection provided by the equipment maybe impaired.<br><br> WARNING<br><br> Page 6<br><br> Declaration of Conformity<br> We <br><br> Peak Scientific Instruments Ltd.<br><br> Of <br><br> Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE<br><br> Declare that:<br><br><br> Equipment: <br><br> Nitrogen Gas Generator<br><br><br><br> Models: <br><br> Genius 3030, Genius 3031<br><br><br> To which this declaration relates, is in conformity with the applicable EC directives,<br> harmonized standards, and other normative requirements.<br> • Low Voltage Directive 2006/95/EC<br> EN 61010-1: 2010 Electrical Equipment for measurement, control and laboratory use.<br> • Electromagnetic Compatibility Directive 2004/108/EC<br> EN 61326-1: 2013 Electrical Equipment for measurement, control and laboratory use.<br> • FCC47 CFR Part 15 Class B<br> Unintentional radiators; Conducted and Radiated emissions limits.<br> All evaluation, testing and certification issued by:<br><br><br> York EMC Services <br><br><br><br> Unit 1, Grangemouth Technology Park <br><br><br><br> Earls Road<br><br> Grangemouth <br><br><br> FK3 8UZ<br><br><br><br> United Kingdom<br><br> Signed: Name: Chris Pugh<br> Date: <br><br> Page 7<br><br> 23/09/2016 <br><br> Position: <br><br> Engineering & Operations Director<br><br> Environmental Declaration<br> We <br><br> Peak Scientific Instruments Ltd.<br><br> Of <br><br> Fountain Crescent, Inchinnan, Renfrewshire, PA4 9RE<br><br> Declare that:<br><br><br> Equipment: <br><br> Nitrogen Gas Generator<br><br><br><br> Models: <br><br> Genius 3030, Genius 3031<br><br> Is fully compliant with the following Directives<br> • 2012/19/EU <br><br> WEEE (Waste of Electrical and Electronic Equipment)<br><br> • 2011/65/EU <br><br> RoHS 2 (Restriction of Hazardous Substance)<br><br> Peak Scientific Instruments Ltd fully complies with its obligations towards the European<br> WEEE (Waste of Electrical and Electronic Equipment) Directive 2012/19/EU. These<br> obligations are being met within the B2B compliance group.<br> Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’ controls to<br> ensure that our products comply with the principles and requirements of the European<br> recast RoHS (Restriction of Hazardous Substances) Directive 2011/65/EU. Similar<br> directives in the United States and China, for example, have also been captured within<br> this program.<br> Where a specific certificate of compliance is required, this can be requested, on<br> a product serial number basis, directly from Peak Scientific Instruments Ltd, by<br> contacting us through our website on www.peakscientific.com<br> Signed: Name: Chris Pugh<br> Date: <br><br> Page 8<br><br> 23/09/2016 <br><br> Position: <br><br> Engineering & Operations Director<br><br> Technical Specification<br> Genius 3030<br> Environment<br> Minimum Operating Ambient Temperature<br> Maximum Operating Ambient Temperature<br> Maximum Altitude<br> Maximum Relative Humidity<br> Minimum Storage Temperature*<br> Maximum Storage Temperature*<br><br> 5°C (41°F)<br> 35°C (95°F)<br> 2000 m<br> 80% Non-Condensing<br> -20°C (-4°F)<br> 60°C (140°F)<br><br> Generator Outlets<br> Curtain Maximum Flow Rate<br> Source Maximum Flow Rate<br> Exhaust Maximum Flow Rate<br> Start-up time<br> Particles<br> Phthalates<br> Suspended Liquids<br> Gas Outlets<br> Drain Outlets<br> Pressure Gauges<br><br> 2 x 12 L/min @ 5.5 Bar (0.42 cfm @ 80 psi)<br> 2 x 24 L/min @ 7.6 Bar (0.85 cfm @ 110 psi)<br> 2 x 8 L/min @ 4.2 Bar (0.28 cfm @ 60 psi)<br> 1 Hour<br> <0.01µm<br> NONE<br> NONE<br> 6 x ¼” BSPP<br> 1 x ¼” BSPP<br> 6<br><br> Electrical Requirements<br> Voltage<br> Frequency<br> Current<br> Input Connection<br> Power Cord (Supplied)<br> Pollution Degree<br> Insulation Category<br><br> 230 VAC ± 10%<br> 50/60 Hz<br> 12 Amps<br> C20 Plug<br> C19 socket to local connection (13A minimum)<br> 2<br> II<br><br> General<br> Dimensions cm (inches) WxDxH<br> Generator Weight Kg (lbs)<br> Shipping Weight Kg (lbs)<br> Heat Output<br><br> Page 9<br><br> 60 x 85 x 132.2 (23.6 x 33.5 x 52.0)<br> 196.5 kg (433lb)<br> 281.5 kg (620lb)<br> 9417 BTU/Hour<br><br> Technical Specification<br> Genius 3031<br> Environment<br> Minimum Operating Ambient Temperature<br> Maximum Operating Ambient Temperature<br> Maximum Altitude<br> Maximum Relative Humidity<br> Minimum Storage Temperature*<br> Maximum Storage Temperature*<br><br> 5°C (41°F)<br> 35°C (95°F)<br> 2000 m<br> 80% Non-Condensing<br> -20°C (-4°F)<br> 60°C (140°F)<br><br> Generator Outlets<br> Curtain Maximum Flow Rate<br> Source Maximum Flow Rate<br> Exhaust Maximum Flow Rate<br> Start-up time<br> Particles<br> Phthalates<br> Suspended Liquids<br> Gas Outlets<br> Drain Outlets<br> Pressure Gauges<br><br> 18 L/min @ 5.9 bar (0.64 CFM @ 85 psi)<br> 26 L/min @ 7.6 bar (0.92 CFM @ 110 psi)<br> 25 L/min @ 4.8 bar (0.88 CFM @ 70 psi)<br> 1 Hour<br> <0.01µm<br> NONE<br> NONE<br> 3 x ¼” BSPP<br> 1 x ¼” BSPP<br> 3<br><br> Electrical Requirements<br> Voltage<br> Frequency<br> Current<br> Input Connection<br> Power Cord (Supplied)<br> Pollution Degree<br> Insulation Category<br><br> 230 VAC ± 10%<br> 50/60 Hz<br> 12 Amps<br> C20 Plug<br> C19 socket to local connection (13A minimum)<br> 2<br> II<br><br> General<br> Dimensions cm (inches) WxDxH<br> Generator Weight Kg (lbs)<br> Shipping Weight Kg (lbs)<br> Heat Output<br><br> Page 10<br><br> 60 x 85 x 132.2 (23.6 x 33.5 x 52.0)<br> 186 kg (411lb)<br> 272 kg (600lb)<br> 9417 BTU/Hour<br><br> Unpacking<br> Although Peak Scientific takes every precaution with safe transit and packaging, it is<br> advisable to fully inspect the unit for any sign of transit damage.<br> Check ‘SHOCKWATCH’ and ‘TIP-N-TELL’ labels for signs of rough handling prior to<br> unpacking<br><br> Any damage should be reported immediately to the carrier and Peak Scientific or the<br> Peak Partner from where the unit was purchased.<br> Follow the unpacking instructions posted on the side of the crate. It will require two<br> people to remove the unit from the shipping crate and to manoeuvre the generator to<br> the desired location.<br> Please save the product packaging for storage or future shipment of the generator.<br> Note: Included with the generator is a “Fittings Kit” containing mains power leads for<br> UK, EU & US and also all the required fittings and warranty registration card. Be careful<br> not to discard these with the packaging. <br><br> Page 11<br><br> Fittings Kit Contents<br> Supplied in the Fittings Kit are all the fittings required to connect the generator to the<br> application. The contents of the Fittings Kit are as follows:<br> 1. ¼” Teflon Tubing x 12m*<br> 2. 6mm PE Tubing x 3m<br> 3. ¼” Compression Fitting x 6**<br> 4. 6mm Push Fit Fitting <br><br><br><br> x 2***<br><br> 5. UK Mains Power Cable x 1<br> 6. EU Mains Power Cable x 1<br> 7. US Mains Power Cable 230v <br><br> x1<br><br> 8. 8mm Hex Key x 1<br> * <br><br> x 9m in Genius 3031<br><br> ** <br><br> x 3 in Genius 3031<br><br> *** <br><br> x 1 in Genius 3031<br><br> All of the generators output ports are located on the output panel at the rear of the<br> unit.<br><br> Page 12<br><br> Installation<br> Generator Environment<br> The generator is designed for indoor use only. It should be installed adjacent to<br> the application(s) it is supplying. If this is not convenient then the unit can be sited<br> elsewhere, however, consideration should be made of the lengths of pipe runs as<br> pressure drops can result from extended runs of pipe.<br> Performance of the generator (like all sophisticated equipment) is affected by ambient<br> conditions. Note should also be taken to the proximity of Air Conditioning outlets.<br> These can sometimes give rise to “pockets” of air with high relative humidity. Operation<br> of the unit within such a pocket could adversely affect its performance. Consideration<br> should also be given to the air flow around the unit. It is recommended that an air gap<br> of 75mm (3”) should be maintained down both sides and at the rear of the unit. Please<br> refer to the drawing below for the general dimensions of the unit.<br> Minimum Operating Ambient Temperature: <br><br> 5 °C (41 °F)<br><br> Maximum Operating Ambient Temperature: <br><br> 35 °C (95 °F)<br><br> Page 13<br><br> Generator Overview<br> 3030 & 3031 General Dimensions<br> 600 mm / 23.6”<br><br> 850 mm / 33.5”<br><br> 1322 mm / 52"<br> The generator must always be placed on a flat, level surface. Failure to<br> do so will affect the performance of the generator.<br> WARNING<br><br> Page 14<br><br> Rear Connections<br> 3030<br><br> Gas Outlets<br> Drain Outlet<br><br> Power Inlet<br><br> 3031<br><br> Gas Outlets<br> Drain Outlet<br><br> Power Inlet<br><br> Page 15<br><br> Electrical Connection<br> Connect the generator to an appropriate 230 volt single-phase supply, refer to the<br> generator serial plate for input specification and ensure your supply matches the<br> requirements.<br> If the appropriate power cord is not supplied; a new plug, rated to at least 12 amps, can<br> be fitted by a qualified electrician.<br><br> WARNING<br><br> This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE<br> EARTHED. Before connecting the unit to the mains supply, please<br> check the information on the serial plate. The mains supply must be of<br> the stated AC voltage and frequency.<br><br> EARTH/GROUND (E):- <br><br> Green & Yellow or <br><br> Green<br><br> LIVE (L):- <br><br> Brown <br><br> or <br><br> Black<br><br> Neutral (N):- <br><br> Blue <br><br> or <br><br> White<br><br><br><br> Electrical requirements for 230V generators is 195V - 253V 50/60Hz. For 195V - 219V a<br> 06-3210 Dual Tap Transformer is required.<br><br> If the equipment is used in a manner not specified by the manufacturer,<br> the protection provided by the equipment maybe impaired.<br> WARNING<br><br> Page 16<br><br> Start-Up Sequence<br><br> CAUTION<br><br> Before the Generator is connected to the application, the Generator<br> should be operated in isolation (i.e. not connected to the application)<br> for thirty minutes. This is to ensure any impurities present are purged<br> from the system. Failure to do this may harm the application.<br><br> Pressure will start to build in the internal storage tanks which can be monitored by<br> watching the output pressure gauges on the front panel. This will climb to the factory<br> set pressure as noted in the specifications.<br> Once this pressure is reached, the compressors will continue to run until the internal<br> tank upper pressure limit is reached and the compressor has run for a period of at least<br> two and a half minutes.<br> The compressors will then rest until the internal tank lower pressure limits is reached.<br> Once this limit is reached the compressors will switch back on again. This compressor<br> cycling is normal and will continue throughout the operation of the Generator.<br> When the system has been operated for a period of 30 minutes, all the internal pipework and storage tanks will have been purged with nitrogen/dry air.<br> Once purged, and the tubes can be connected at the rear of the unit. The generator<br> should be allowed to run for 1 hour to allow the gas to reach purity.<br><br> Normal Operation<br> The Genius 3030/3031 Gas Generator is designed specifically to minimize operator<br> involvement. Given that the system is installed as described in earlier sections and is<br> serviced in accordance with the specified maintenance recommendations (see Service<br> Requirements), then it should simply be a matter of turning the Generator on when it is<br> required.<br> The Generator will automatically produce the factory set flow and pressure as detailed<br> in the Technical Specifications.<br><br> On Demand Gas<br> The generator will produce nitrogen on demand. If the application is operating<br> and requires a gas flow, the system it is connected to will supply this to suit the<br> requirements of the application. If the application requirement for gas stops, the system<br> will also stop, once it has reached its upper set limit in the internal storage tanks. If the<br> demand from the application starts again, the system will detect the demand for gas<br> and will automatically start again to suit the demand.<br><br> Page 17<br><br> Generator Cycling<br> The Generator is designed for the internal compressors to cycle. This cycling reduces<br> the duty (run time) on the compressors. The rate at which they cycle will be dependent<br> on the gas required to satisfy the demand of the application. If the application demands<br> the maximum gas flow of the Generator, the compressor duty will be higher, (the rest<br> period in the compressor cycle will be shorter). If the application demand is lower than<br> the maximum gas flow, then the duty on the compressors will decrease, (the rest period<br> in the compressor cycle will be longer). If the Generator is installed in an extreme<br> environment or is subjected to low supply voltage or high altitude the compressors may<br> undergo periods where they do not cycle.<br><br> Unusual Operation<br> If at any time the generator begins to emit excessive noise or vibration, then it should<br> be switched off and you should contact Peak Scientific or the Peak Partner from which<br> the generator has been purchased.<br><br> Page 18<br><br> Connecting to the application<br> Once the initial purge run of 30 minutes has completed, and the generator has been<br> running for 1 hour, it is ready to be connected to the application(s).<br> The pressure in the internal storage tanks must be allowed to dissipate<br> before connecting the generator to the application(s)<br> CAUTION<br><br> Attach the appropriate fittings to the outlets of the generator. Using the tubing<br> supplied, connect the outlets of the generator to the inlets on the application.<br> If you require more tubing than is supplied please refer to the Tubing Lengths section.<br><br> CAUTION<br><br> Once the tubing is connected to the application, please ensure that it<br> is thoroughly checked for being leak-tight. Even the slightest leak in<br> the gas supply between the generator and the application can lead to<br> a reduction in efficiency.<br><br> Tubing Lengths<br><br> CAUTION<br><br> The diameter of the tubing which will be connected to the gas outlet is<br> important and is determined by the length of tubing required. Failure<br> to follow these recommendations could lead to pressure between<br> generator and application.<br><br> < 10 meters: <br><br> Use 6/4 (6mm O/D, 4mm I/D) P.T.F.E. tubing.<br><br> > 10 - 40 meters: Use 10/8 (10mm O/D, 8mm I/D). Tubing and fittings not <br><br> supplied in the fittings kit.<br> > 40 metres: <br><br><br> Please contact Peak Scientific with the relevant distance andwe<br><br> will calculate the flow resistance and the tubing size required.<br><br> A combination of 6/4 and 10/8 tubing may be used to ensure that there is no large<br> diameter tubing within the lab (i.e. for the first 20 meters from the Generator use 10/8<br> and the final 10 meters to the application use 6/4 tubing). Keep the connections and<br> bends to a minimum.<br><br> The imperial equivalents are: 6/4 = 1/4” O/D, 3/16” I/D.<br><br><br> Page 19<br><br> 10/8 = 3/8” O/D, 5/16” I/D.<br><br> Service Requirements<br> Service Schedule<br> Purchase Interval<br><br> Component<br><br> Part No.<br><br> Qty.<br><br> Genius 3030 Annual Maintenance Kit*<br><br> 12 Months<br><br> Kit Includes;<br> 4 x 1st Stage Coalescing Filter Element<br> 4 x 2nd Stage Coalescing Filter Element<br> 4 x RAC Filter Element<br> 1 x Inlet Filter Element<br> 4 x 3/2 Valve<br> 8 x 2/2 Valve<br> 8 x Plug In Relay<br> 4 x Comp. Service Kit<br><br> 08-9430<br> or<br><br> 1<br><br> 08-9431<br><br> Genius 3031 Annual Maintenance Kit*<br> Kit Includes;<br> 4 x 1st Stage Coalescing Filter Element<br> 4 x 2nd Stage Coalescing Filter Element<br> 2 x RAC Filter Element<br> 1 x Inlet Filter Element<br> 3 x 3/2 Valve<br> 8 x 2/2 Valve<br> 7 x Plug In Relay<br> 4 x Comp. Service Kit<br> Compressor<br> Assembly **<br><br> 08-9432<br> or<br><br> 1<br><br> 08-9433<br><br> 08-8141<br> Compressor Assembly 3030/3031<br><br> or<br><br> 4<br><br> 08-8384<br><br> * Please quote your generator serial number when ordering your Annual Maintenance<br> Kit to ensure selection of the appropriate kit for your generator.<br> ** If your compressors have been refitted 3 times they must now be replaced. Please<br> note that when replacing the compressor assembly, the full Annual Maintenance Kit will<br> not be required. Please contact your service provider for more information.<br><br> Page 20<br><br> Service Indication<br> The Genius 3030 & 3031 will notify the user of the service interval for the internal<br> compressors. The Generators have the following Service Indication Stages:-<br><br> Stage 1<br> Once either compressor requires a service the LED indicator (yellow) on the front of the<br> Generator will illuminate.<br> This is to make the user aware that a service of the Generator is due and should be planned at<br> the earliest convenience. The Generator will continue to operate as normal with the LED on.<br> Stage 2<br> If the service is not completed the Generator will continue to run. After 2 weeks, the service<br> LED indicator (yellow) will start to flash.<br> This is to make the user aware that the service of the Generator is now overdue and must be<br> completed immediately to ensure the continuous trouble free operation of the Generator.<br><br> Service Indication Reset<br> Once the service has been completed the Service Indication LED can be reset in the<br> main control PLC. This will be performed by the Peak Service Engineer or trained service<br> representative that completes the service operation.<br><br> High Duty Indication<br><br> The Genius 3030 & 3031 have a ‘HIGH DUTY’ indicator on the front panel. This indicator<br> monitors the running condition of the internal compressors and illuminates when they have<br> been operating continually for a period of 8 hours.<br> There are a number of extreme conditions that can affect the duty cycling of the<br> compressors inside the generator. These extremes include very high ambient temperatures,<br> low supply voltages, a very high flow requirement and locations of high altitude. Any one<br> of these or a combination of a number of these extremes can be evident in a customer site.<br> While the generator is designed to operate fully in these conditions it should be noted that<br> the effect of these extremes can force the compressors to run continually. The compressors<br> are fully capable of running continually with no detrimental effect, however users may find<br> the generator reaches its service interval quicker.<br><br> High Duty Indication Reset<br> If the compressors have been operating continually for a period of 8 hours the indicator<br> light will be illuminated. Once the compressors return to a cycling mode the indicator<br> light will automatically switch off. There is no manual intervention required.<br><br> Indication of Fault<br> In most installations the ‘HIGH DUTY’ indicator will never be illuminated. If your Genius<br> 3030/3031 Generator has been operating for a significant period of time, then suddenly<br> develops a ‘HIGH DUTY’ indication with no apparent change in environmental conditions<br> or flow requirements, it may be indicative of a problem with the system such as an external<br> leak or imminent compressor failure.<br> If this is the case you should contact Peak Scientific or your service provider.<br> It should be noted that the Generator will continue to operate so long as it can maintain<br> pressure during this indication.<br> Page 21<br><br> Peak Protected<br> With Peak Scientific you invest in not only a product but peace of mind. With a network of<br> certified Peak engineers stationed throughout the globe, Peak’s rapid response team are<br> never far away and our commitment is to keep your generator running day in, day out,<br> protecting your laboratory workflow.<br><br> [Peak Protected] can provide…<br><br> Installation<br><br> A dedicated Peak engineer will visit<br> your lab to install and setup your<br> generator<br><br> IQ/OQ<br><br> Certified assurance for applications<br> requiring documented qualification<br><br> Complete plan<br><br> Swift response by a Peak Service<br> Engineer within 72 hours & planned<br> preventative maintenance<br><br> Spares<br><br> Genuine Peak parts with express<br> delivery, ensuring optimal<br> performance and lifetime<br><br> Premium Protected<br><br> Guaranteed rapid on-site response<br> within 24 hours & planned<br> preventative maintenance<br><br> Technical Support Hotline<br><br> Around the clock support by phone<br> or online with our global technical<br> helpdesk<br><br> To find out more about protecting your investment visit: www.peakscientific.com/protected<br><br> Page 22<br><br> Cleaning<br> Clean the outside of the generator only using warm soapy water and a clean damp<br> cloth. Ensure all excess fluid is thoroughly removed from the cloth prior to use.<br> Cleaning should only be undertaken with the power switched off and<br> the power cord removed from the rear of the generator.<br><br> CAUTION<br><br> Under no circumstances should any solvents or abrasive cleaning<br> solutions be used as these can contain fumes that could be harmful to<br> the generator.<br> Care should be taken with Leak Detections Liquids.<br><br> CAUTION<br><br> Page 23<br><br> Troubleshooting<br> Problem<br><br> Possible Solution<br> • Ensure power cord is plugged into the<br> Generator and that the power socket is<br> turned on.<br><br> The Generator will not switch on and the<br> power switch does not illuminate.<br><br> The Generator will not switch on but the<br> power switch is illuminated.<br><br> • Check the fuse in the power cord plug.<br> • Contact your service provider.<br><br> • Disconnect power cord from the rear of<br> the Generator. Open the left hand panel<br> are check that both circuit breakers are<br> turned on (switch in the up position).<br> Reconnect power cord.<br> • Contact your service provider.<br><br> Compressors are running but pressure is not<br> building.<br><br> The mass spec is reporting low pressure.<br><br> Yellow “SERVICE” LED on front panel is on<br> constantly.<br><br> *Yellow “SERVICE” LED on front panel is<br> flashing.<br><br> Yellow “HIGH DUTY” LED on front panel is on<br> constantly.<br><br> • Check pressure gauges are showing<br> normal pressure.<br> • Contact your service provider.<br><br> • Contact your service provider.<br> • A compressor(s) due for service. Contact<br> your service provider.<br> • Refer to Service Indication section of this<br> manual for further information.<br> • A compressor(s) is overdue for service.<br> Contact your service provider urgently.<br> • Refer to Service Indication section of this<br> manual for further information.<br> • A compressor(s) has not cycled for a<br> period of 8 hours. Refer to the High Duty<br> Indication section of this manual.<br> • Ensure ambient temperatures are within<br> the specification.<br> • Ensure there are no leaks between the<br> Generator and the mass spec.<br><br> Page 24<br><br> Go Online or Complete and Return<br> We know that registering any of your recently purchased products is not the<br> first thing on your mind- but it is very important to both of us. Not all warranties<br> are alike and Peak Scientific stand out against other gas suppliers as we offer a<br> comprehensive, quick response, on-site warranty. This means that in the very<br> unlikely case that your gas generator develops a fault we have rapid support<br> teams on-hand around the world who are able to come to your lab and get you<br> back up and running in no time.<br> Register for your comprehensive 12 month on-site warranty with ease online at<br> www.peakscientific.com/protected.<br> Alternatively, you can send the completed form to Peak Scientific by post or<br> email at warranty@peakscientific.com.<br><br> Go Online or Complete and Return<br> You can register for your FREE 12 month Warranty with ease online at<br> www.peakscientific/protected.<br> Alternatively, you can send the completed form to Peak Scientific by post or<br> email at warranty@peakscientific.com.<br><br> Product Warranty Registration<br> Contact name<br> Email address<br> Company<br> Address<br> City/town<br> Postcode<br> Country<br> Telephone<br> Generator serial #<br> Model type<br> Installation date<br> Do you still use an<br> alternative gas solution i.e.<br> cylinders or bulk liquid?<br><br> Yes<br><br> What gas requirements do<br> you have in your lab?<br><br> Hydrogen<br><br> No<br><br> Nitrogen<br><br> Zero Air<br><br> Extend your cover with<br> Peak Scientific offer comprehensive gas generator after sales support packages.<br> Peak [Protected] aftercare support can guarantee an on-site response within<br> 72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time<br> fix rate. See our enclosed Peak [Protected] leaflet for further information.<br> Important!<br> You have 1 month to register your Peak Scientific product from the date of installation. Once registered<br> the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your<br> generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com.<br> For generators that remain unregistered after 1 month from the shipment date, the warranty will be<br> considered active from the date of factory dispatch.<br> * Complete Plan only<br><br> <br> <br> <br> <br><br> Important!<br> You have 1 month to register your Peak Scientific product from the date of<br> installation. Once registered the warranty will be honoured for a period of 12<br> months. If you wish to defer the installation of your generator, you must notify<br> Peak Scientific immediately by emailing warranty@peakscientific.com. For<br> generators that remain unregistered after 1 month from the shipment date, the<br> warranty will be considered active from the date of factory dispatch.<br> Page 25<br><br> Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries<br> across every continent around the world. This allows us to provide an industry-leading rapid response<br> service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top<br> priority.<br> To discuss Peak Protected generator cover and payment options speak to your local Peak<br> Representative or for further information contact: protected@peakscientific.com<br><br> Peak Scientific<br> Fountain Crescent<br> Inchinnan Business Park<br> Inchinnan<br> PA4 9RE<br> Scotland, UK<br> Tel: +44 141 812 8100<br> Fax: +44 141 812 8200<br> For further information on any of our<br> generator products please contact<br> marketing@peakscientific.com<br> Genius3030-3031UserManualRev3RSID128PNUM-000506/03/19<br><br></p>

Comments
Search for similar resources