NG3000-5000 (All Models)
Installation Guide

NG3000-5000 Installation Guide Rev 1 PN IG-0021 17/08/17 RS-2100

Change History
Rev

Comment

Name

Date

How to use this Installation Guide
This document is intended to be used only as a Quick Start Guide, to facilitate safe and
correct installation and initial configuration of your Peak Scientific gas generator.
For more extensive user operation directions, we recommend you download the User
Manual from the website.

Please visit www.peakscientific.com/downloads to
download the full User Manual for your gas generator.
Thank you for selecting Peak Scientific to meet your laboratory gas generation needs,
and should you require any further assistance or support please do not hesitate to
contact Peak Scientific or Peak Partner from which you purchased your generator.

Page 2

Safety Notices
Peak Scientific Instruments cannot anticipate every possible circumstance which may
represent a potential hazard. The warnings detailed within this document detail the
most known potential hazards, but by definition cannot be all inclusive. If the user
employs an operating procedure, item of equipment or a method of working which
is not specifically recommended by Peak Scientific, the user must ensure that the
equipment will not be damaged or become hazardous to persons or property.

Symbols
This document uses the following symbols to highlight specific areas important to the
safe and proper use of the Generator

WARNING

A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
personal injury or in the worst case death. Do not proceed beyond a WARNING
notice until the indicated conditions are fully understood or met.

CAUTION

A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause
damage to the Generator or the Application. Do not proceed beyond a CAUTION
notice until the indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the Generator has been removed
before proceeding.

Safety Notice to Users

WARNING

WARNING

These instructions must be read thoroughly and understood before
installation and operation of your Peak Generator. Use of the generator
in a manner not specified by Peak Scientific MAY impair the SAFETY
provided by the equipment.
When handling, operating or carrying out any maintenance, personnel
must employ safe engineering practices and observe all relevant local
health and safety requirements and regulations. The attention of UK
users is drawn to the Health and Safety at Work Act 1974, and the
Institute of Electrical Engineers regulations.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.

WARNING

Page 3

Fittings Kit

x2

1/4” - 6mm Push Fit Elbow Fitting 02-4331

x1

US Mains Cable C13 6-15 04-1029

x3m

PTFE 6mm Tubing 00-1302

x1

US Mains Cable C13 5-15 04-1039

x4
No. 8 Screw 00-4075

x1

UK Mains Cable C13 04-1030

x1

1/4” x 1/8” Compression Fitting 02-1000

x4

No. 8 Wall Plug 00-4076

x1

EU Mains Cable C13 04-1038

Page 4

x1

1/4” x 1/4” Compression Fitting 02-4421

1.

Unpack the generator from the shipping crate and position on a flat surface, in
desired area.

2.

The NG range generator is designed to be mounted against a wall for safety reasons.
Locate the screw in the top right rear corner of the unit, beside the yellow warning
label.
Page 5

3.

Remove the screw from the generator this should be repeated for the other
side of the unit, and retain.

4.

Next, using the screw which was removed, fit the bracket and washers provided to the
generator. Again this should be repeated for the other side. The bracket is adjustable to
accommodate varying kickboard widths.
Page 6

5.

Finally, using the dimensions provided, fix the wall plugs to the wall, ensuring wall plug
is suitable for the type of wall. If not, use the correct type. Secure the generator to the
wall with the screws from the fittings kit.

6.

For NG 3000-5000(A) before the unit is used, the transit brackets must first be
removed from the compressor.
For NG 3000-5000 please proceed to step 10
To remove the transit bracket first remove the 11 screws on the front panel as shown.
then remove the front panel from the generator.
Page 7

7.

Then remove the front panel from the generator.

8.

Now locate the red transit bracket attached to the compressor foot plate, and remove
the two screws on the bracket.

Page 8

9.

Next remove the transit bracket by first lifting up and then out of the generator.
Replace the front panel and secure it to the generator using the 11 screws that were
previously removed.

10.

02-4421

Attach the ¼” Compression Fitting 02-4421 to the generators gas outlet.

Page 9

11.

04-1030/04-1029/
04-1038/04-1039
Select the appropriate mains cable from the fittings kit and plug the IEC 60320/C19
cable into the mains input at the side of the generator.

12.
UK

EU

US
110V

CAUTION

US
230V

110VAC 50/60Hz OR 230VAC 50/60Hz

Plug the mains cable into the corresponding 110VAC 50/60Hz OR 230VAC 50/60Hz
single phase power supply.
CAUTION ensure the correct cable has been selected for your electrical supply
Page 10

For non-gas versions of the MS Table proceed to step 15.

13.

Switch the generator power ON using the switch on the side of the unit.

14.

8
hours

Leave the generator switched on for a period of 8 hours to purge the system.
The pressure gauge on the front panel will gradually increase to the factory set
pressure.
Page 11

15.

02-XXXX

Attach the ? Tubing to the fitting attached to the generators gas outlet and connect to
the gas inlet of your instrument.

16.

/
CONGRATULATIONS
Your Peak Scientific gas generator is now fully installed, operational and ready to
supply gas on demand to your instrument.
Page 12

General Notes

The Teflon tube supplied in the fittings kit is to allow the generator to be installed
adjacent to the instrument it is supplying. If the generator is to be installed further
away from the instrument then attention needs to be paid to pressure drops that could
occur. The maximum distance away from the instrument the generator can be placed
still using 6mm (4mm internal diameter) or ¼” (3/16” internal diameter) tubing is 10m.
For further information relating to tubing lengths please refer to the user manual.
1.

Please familiarise yourself with the full User Manual available at www.peakscientific.
com/downloads. This includes all other technical specifications, operating
instructions, service requirements, contact details and trouble shooting.

Page 13

Go Online or Complete and Return
We know that registering any of your recently purchased products is not the
first thing on your mind- but it is very important to both of us. Not all warranties
are alike and Peak Scientific stand out against other gas suppliers as we offer a
comprehensive, quick response, on-site warranty. This means that in the very
unlikely case that your gas generator develops a fault we have rapid support
teams on-hand around the world who are able to come to your lab and get you
back up and running in no time.
Register for your comprehensive 12 month on-site warranty with ease online at
www.peakscientific.com/register.
Alternatively, you can send the completed form to Peak Scientific by post or
email at warranty@peakscientific.com.

Go Online or Complete and Return
You can register for your FREE 12 month Warranty with ease online at
www.peakscientific/protected.
Alternatively, you can send the completed form to Peak Scientific by post or
email at warranty@peakscientific.com.

Product Warranty Registration
Contact name
Email address
Company
Address
City/town
Postcode
Country
Telephone
Generator serial #
Model type
Installation date
Do you still use an
alternative gas solution i.e.
cylinders or bulk liquid?

Yes

What gas requirements do
you have in your lab?

Hydrogen

No

Nitrogen

Zero Air

Extend your cover with
Peak Scientific offer comprehensive gas generator after sales support packages.
Peak [Protected] aftercare support can guarantee an on-site response within
72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time
fix rate. See our enclosed Peak [Protected] leaflet for further information.
Important!
You have 1 month to register your Peak Scientific product from the date of installation. Once registered
the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your
generator, you must notify Peak Scientific immediately by emailing warranty@peakscientific.com.
For generators that remain unregistered after 1 month from the shipment date, the warranty will be
considered active from the date of factory dispatch.
* Complete Plan only






Important!
You have 1 month to register your Peak Scientific product from the date of
installation. Once registered the warranty will be honoured for a period of 12
months. If you wish to defer the installation of your generator, you must notify
Peak Scientific immediately by emailing warranty@peakscientific.com. For
generators that remain unregistered after 1 month from the shipment date, the
warranty will be considered active from the date of factory dispatch.
Page 14

Please visit www.peakscientific.com/downloads to
download the full User Manual for your gas generator.

Peak Scientific has highly trained, fully certified Field Service Engineers located in over 20 countries
across every continent around the world. This allows us to provide an industry-leading rapid response
service to our customers. With [Peak Protected], your laboratory’s productivity becomes our top
priority.
To discuss Peak Protected generator cover and payment options speak to your local Peak
Representative or for further information contact: protected@peakscientific.com.

Peak Scientific
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Tel: +44 141 812 8100
Fax: +44 141 812 8200
For further information on any of our
generator products please contact
discover@peakscientific.com
NG3000-5000 Installation Guide Rev 1 PN IG-0021 17/08/17

Search for similar resources

Remove