za035180a - User Manual
Original PDF File1.9 MB |
Download |
View directly in browser1.9 MB |
View in browser |
Resource ID
238
Access
Open
Contributed by
Derek Rennie
Review date
01 May 24
Title
za035180a - User Manual
Revision Number
12
Revision Details
Reviewed 31/12/20 - BP
Keywords
User Manual,
Product Range
Other
Company Brand
Peak Scientific
Reviewed on 3rd may 2017 - LC
Extracted text
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Zero Air Gas Generator
With Compressor ZA035A - ZA180A
Directions For Use
Peak Scientific Instruments Ltd Fountain Crescent Inchinnan Business Park Inchinnan Renfrewshire PA4 9RE T.(Europe) +44 (0) 141 812 8100 T.(USA) +1 866 647 1649 (sales) T.(USA) +1 866 732 5427 (tech support) F.(Europe) +44 (0) 141 812 8200 info@peakscientific.com sales@peakscientific.com support@peakscientific.com
www.peakscientific.com
ZA035-180A Issue 11
1
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Document Change History
Issue No
1 2 3 4 5 6 7 8 9 10 11
Changed
First Issue Spare Parts Moisture Carry Over Re-setting Information 2002 revised design Compressor Service no longer valid USA Technical support number updated New style front added Filter Details Updated Remove ref. to PSA Air Purifier Updated 110volt compressor model
Initials
SGM SGM SGM SGM SGM SGM FAD FAD GL SF GL
Date
21/10/98 11/12/98 01/04/99 11/6/99 14/11/01 07/01/03 16/11/04 30/03/05 23/06/06 04/09/06 12/10/06
ZA035-180A Issue 11
2
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Contents
Page No Document Change History Warranty Statement Introduction Unpacking & Installation Electrical Connection Air Connection Principal of Operation Commissioning Routine Maintenance Troubleshooting Technical Specifications System Diagrams Maintenance Log Notes 2 5 6 6 6 7 7 8 9 12 13 14 16 17
ZA035-180A Issue 11
3
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Safety First
It is important that you thoroughly read and understand this manual before operating or servicing this Peak Scientific Instruments Gas Generator. PLEASE NOTE THE FOLLOWING CAUTIONS AND WARNINGS FOR YOUR OWN SAFETY.
! Caution –
Only authorized persons should operate or service this equipment.
! Warning –
To avoid risk of electrical shock, personal injury, or death disconnect power before removing any cover of this equipment.
! Caution –
To avoid risk of personal injury NEVER disconnect any pipe, fitting, or filter bowl while the system is pressurized. Always allow pressure to dissipate before opening the system.
! Warning –
The Catalytic Process requires very high temperatures. Internal surfaces and copper lines are extremely hot and will cause burns. Always allow the generator to cool before carrying out any servicing.
ZA035-180A Issue 11
4
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Warranties and Liabilities
1) The Company warrants that it has title to the Goods. 2) Subject to the provisions of this clause the Company warrants that the Goods shall comply in all material
respects with any specification referred to in the Order Confirmation (as the same may be amended) and shall, subject thereto, be free from defects in material and workmanship for the lesser of a period of twelve months from the date of delivery or thirteen months from the date of dispatch from the factory.
3) Save as provided in this clause and except where the Goods are sold to a person dealing as a consumer
(within the meaning of the Unfair Contract Terms Act 1977) all warranties, conditions or other terms implied by statute or common law are hereby expressly excluded save to the extent they may not be lawfully excluded. When the Goods are sold to a consumer within the meaning of the Unfair Contract Terms Act 1977 their statutory rights are not affected by the provisions of this clause.
4) In the event of the Customer making a claim in respect of any defect in terms of clause 2 hereof the
Customer must:-
stored, serviced and used and without prejudice to the generality of the foregoing that any defect is not the direct or indirect result of lack of repair and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or incorrect spare parts; and 4.2) allow the company to inspect the Goods and/or any installation and any relevant packaging as and when reasonably required by the Company.
4.1) reasonably satisfy the Company that the Goods have been properly installed, commissioned,
5) Subject to the Company being notified of any defect as is referred to in sub-clause 2 hereof within a
reasonable time of it becoming apparent and subject always to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or repair the defective Goods or refund a proportionate part of the Price. The Company shall have no further liability to the Customer (save as mentioned in sub-clause 6 hereof).
6) The Company shall be liable to indemnify the Customer in respect of any claim for death or personal injury
to any person in so far as such is attributable to the negligence or breach of duty of the Company or any failure by the Company to comply with the provisions of sub-clause 2 hereof.
7) Save as provided in sub-clause 2 hereof the Company shall not be liable in respect of any claim by the
Customer for costs, damages, loss or expenses (whether direct, indirect, consequential or otherwise) or indemnity in any respect howsoever arising including, but not by way of limitation, liability arising in negligence (other than pursuant to clause 6 above) that may be suffered by the Customer or any third party,
SAFETY NOTICE TO USERS
These instructions must be read thoroughly and understood before installation and operation of your Peak Gas Generator. Use of the Generator in a manner not specified by Peak Scientific Inst. MAY impair the SAFETY provided by the equipment. When handling, operating or carrying out any maintenance, personnel must employ safe engineering practices and observe all relevant local health and safety requirements and regulations. The attention of UK users is drawn to the Health and Safety at Work Act 1974, and the Institute of Electrical Engineers regulations.
ZA035-180A Issue 11
5
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
1
Introduction
The Peak Scientific Instruments range of Zero Air Gas Generators is designed to produce a constant flow of Zero Grade Air with a Hydrocarbon content (as Methane) of less than 0.1 ppm.
2
Unpacking and Installation.
Although Peak Scientific take every precaution with safe transit and packaging, it is advisable to fully inspect the unit for any sign of transit damage.
ANY DAMAGE SHOULD BE REPORTED IMMEDIATELY TO THE CARRIER AND PEAK SCIENTIFIC OR THE DISTRIBUTOR FROM WHERE THE UNIT WAS PURCHASED.
After unpacking and a visual inspection, the unit should be placed in a ventilated area away from direct sunlight. Care should be taken not to obstruct the ventilation holes on the sides of the unit nor the fan outlet to the rear. The generator should be placed on a steady and level base. The generator will fit under most workbenches. Alternatively it may be placed on a workbench or in any convenient location. Performance of the generator (like all sophisticated equipment) is affected by ambient temperatures and humidity. Continuous operation in ambient temperatures exceeding 25°C will lead to a reduction in capacity and prolonged operation in temperatures exceeding 30°C will shorten the life of the unit. Operation in relative humidity exceeding 70% may overload the filtration system and result in moisture carry-over. Additional moisture traps should be installed downstream of the generator should ambient regularly exceed 70% Rh. and also if the generator is any distance from the application. Moisture traps or coalescers should be located as close to the application as possible. Note should also be taken of the proximity of Air Conditioning outlets. These can sometimes give rise to “pockets” of air with high relative humidity. Operation of the generator within such a pocket could adversely affect its performance.
3
Electrical Connection
Important Electrical Notice
This unit is classified as SAFETY CLASS 1 equipment. THIS UNIT MUST BE EARTHED. Before connecting the unit to the mains supply, please check the information on the serial plate. The mains supply must be of the stated AC voltage and frequency.
EARTH/GROUND (E):LIVE (L):Neutral (N):Fuse
Green & Yellow Brown Blue
or
Green Black White
The generator protection fuse is found in the pull out drawer of the mains inlet IEC euroconnector located on the bottom right hand side of the cabinet adjacent to the off/on switch. The fuse is rated at 10 AMP. A spare fuse is also provided in the drawer. Connect the generator to a single phase supply using the power cord provided.
ZA035-180A Issue 11
6
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
4
Air Connection
The Zero Air Generator has its own built-in air compressor and therefore does not require an external compressed air source. The generator has two ¼” BSP female bulkhead connections. The Zero Air outlet fitting is located on the left hand side lower and should be coupled to the application. At the rear of the unit is the condensate drain and should be led to a safe place. In all but a few areas of extremely low relative humidity there will be a significant amount of water liberated by the generator. This should be drained safely away or unsightly stains could result on floors or work surfaces. This water is clean and can be drained into normal domestic drains. .5
Principal of Operation
The ZAxxxA Zero Air generator works on the fundamental principal of Catalytic Oxidation as illustrated in the following pneumatic diagram.
Heater Element Thermocouple
Unloading Valve Heat Exchanger
Pressure Regulator
Zero Air
Front Panel
Membrane Dryer
Pressure Switch Catalytic Chamber Filter Separator
Outlet
Heat Exchanger
Receiver Compressor
ZAxxxA Pneumatic Diagram
Ambient air is compressed and after cooling is passed through the Filter Separator which removes liquid moisture to and particles down to 0.1 micron. The air is then passed through a Membrane Dryer to remove any remaining moisture and on into and internal Receiver. The receiver is designed to provide volume within the system to cope with different flow rates and to allow the compressor to operate a duty cycle. When the Receiver reached its maximum pressure the Pressure Switch will operate stopping the compressor and opening the unloading valve.
ZA035-180A Issue 11
Zero Air Generation
7
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Air from the Receiver is regulated for pressure and flow and passed to the 'Zero Air' catalytic combustion chamber. This works on the principle of catalytic oxidation where hydrocarbons from the incoming compressed air supply are cracked to carbon dioxide and water. The hydrocarbon level in the form of methane is reduced to <0.1ppm. For this process to work the catalyst requires to be heated to approximately 400 degrees Celsius. The free Carbon and Hydrogen atoms then combine with Oxygen in the air to form Carbon Dioxide and Water. After the catalytic chamber the air passes through a cooling coil to reduce its temperature to a safe level.
6
Commissioning
With the generator installed as described earlier remove the lower front cover. Check that all the internal components are securely located and have not become dislodged during transit. Re-fit the front cover before proceeding further. The Upper Front Panel is shown below.
Pressure Gauges
Temperature Control
Tank Pressure Ready Warm up Zero Air Pressure
PEAK
Zero Air Generator
Status Lamps
Connect the generator to the electrical supply and turn the unit ON. The unit will begin to build up pressure as will be seen from the two pressure gauges. The lower gauge indicates the Output Pressure which is factory-set at 80 psig. The upper gauge indicates the internal receiver pressure which will fluctuate between 120 and 90 psig. The Digital Display shows the Catalyst Chamber temperature. This is factory set at 400º There are two C. Status LEDs on the front panel. Once the Catalyst reaches operating temperature these will change from RED to GREEN indicating that the generator is ready for use. The generator should reach operating temperature within 40 minutes of switch-on.
Check that the cooling fans are operating and exhausting air out of the generator.
ZA035-180A Issue 11
8
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
7 Routine Maintenance WARNING: Servicing and/or repair of the Generator should only be undertaken
by a TECHNICALLY COMPETENT PERSON with the Generator safely isolated.
Due to the simplicity of the design and the small number of moving parts the Peak Gas Generator will have a long and trouble free life. However the following components should be replaced as follows:
Compressor Inlet Filters Filter/Separator/Silencers Compressor Units (the lesser of)
Every 6 months Every 12 months Every 6000 hours or 18 months
Service kits are available for all routine maintenance; please contact the factory for further details.
FAILURE TO FOLLOW THE PRESCRIBED MAINTENANCE PLAN WILL INVALIDATE THE PRODUCT WARRANTY.
Compressor Maintenance
The Intake Filter requires periodic replacement. Initial inspection should be after 500 hours operation. Most compressor related problems can be prevented by keeping the filter clean. A dirty inlet filter will decrease compressor performance and may shorten its life. The compressor head surfaces and motor casing become very HOT during operation. Do not touch these parts until the unit has been switched off and allowed to cool. Switch the Generator OFF and disconnect it from the Electrical supply. Remove the fuse from the Eurosocket to prevent the generator being inadvertently switched on by another person. This is a non-lubricated compressor and should never be oiled. Oiling this compressor will cause damage.
ZA035-180A Issue 11
9
PEAK Scientific Instruments Ltd
Instructions for use Manual Catalytic Chamber
Zero Air Gas Generator with Compressor th 12 October 2006
The Catalytic Chamber is heated to 400ºC and will cause severe burns if touched. If for any reason the chamber or its associated parts need to be examined the generator must be switched off and allowed to cool. THIS COULD TAKE UP TO 10 HOURS. The Catalytic Chamber takes the form of cylindrical chamber with a heated central core. The annular space is specifically designed to allow the required contact time with the catalyst to ensure complete oxidization. The complete chamber is contained within an insulated enclosure as shown below.
Air Inlet Line
Thermocouple
Heater
Thermal Fuse
Regardless of the supply voltage the heater is rated at 110 Vac. This minimizes the voltdrop across the conductors and prolongs the life of the element. The Heater is contained within a stainless steel sleeve to facilitate removal should replacement be required.
Heater
Thermocouple Thermal Fuse
The thermocouple is “K” type spring-loaded bayonet fitting to ensure good contact with the chamber core.
The thermal fuse is provided as a safety feature to cut supply to the heater thus preventing chamber overheating in the event of a control or ventilation failure. It is a fail-safe device and if blown requires replacing. Note: - The thermal fuse will not blow under normal operation. A blown thermal fuse indicates that a fault exists which MUST be rectified before attempting to replace the thermal fuse. Refer to the trouble shooting chart on page 12 for guidance.
ZA035-180A Issue 11
10
PEAK Scientific Instruments Ltd
Instructions for use Manual Inlet Filter / Separator Elements
Zero Air Gas Generator with Compressor th 12 October 2006
These should be changed at intervals as indicated below. In addition filter bowls should be cleaned and the operation of the auto-drains should be checked. The Generator MUST be de-pressurised prior to attempting to remove ANY filter bowl. Failure to do this may cause injury.
Compressor Inlet Filter
This should be changed at 6-month intervals. Part Number is 02-4187 and the filter is located as shown.
Remove the cover by rotating it anti-clockwise ¼ turn. The element can then be removed. Re-fitting is the reverse procedure.
Coalescing Filter Element
This element should be changed at 12-month intervals. Part Number is 02-4335.
Pull down the black slide, turn the bowl ¼ turn counter clockwise to release. The element then un-screws. Re-assembly is the reverse procedure.
ZA035-180A Issue 11
11
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
8
Troubleshooting
No Gas Delivery Check Presure Gauges OK No flow Low Air Escaping From Drain No Yes Clean Autodrain
Check Flow Rate
Service Compressor
OK Blocked Chamber Contact Factory
Green High CH4 Check Front Panel LED Red Check Flow Rate
> 18l/min Reduce Demand
< 18l/min 400 Check Front Panel Display No Display No Fault - Check Elsewhere
EEE
Replace Faulty Thermocouple
No Check 12V @ termi nals 8&9 Replace Faulty Power Supply
Yes
Replace Faulty Display Module
0V Voltage At Heater Check Thermal Fu se Replace Faulty SSR
110 V
Replace Faulty Vent Fan
30 Ohms Check Heater Resistance Replace Heater
ZA035-180A Issue 11
12
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
9
Technical Specifications
General Details
5 oC (41 oF) 30 C (113 F)
o o
Minimum Operating Ambient Temperature Maximum Operating Ambient Temperature Inlet Conditions (Free of oil and bulk moisture) Minimum Air Inlet Pressure Maximum Air Inlet Pressure Maximum Hydrocarbon Content Start up time for specified hydrocarbon concentration
N/A N/A N/A 40 minutes
Model
Physical Details ZA035A
3.5 450 250 18.0 3.1A 6.9A 88x43x41 39x17x16 62Kg 136lb
ZA070A
7.0 450 250 18.0 3.1A 6.9A 88x43x41 39x17x16 62Kg 136lb
ZA180A
18.0 450 250 27.0 4.9A 8.8A 88x43x41 39x17x16 64Kg 141lb
Max Output (Litres/min) Heater Watts Compressor Watts Fan Watts Electrical Requirements (230V 50Hz) (110V 60Hz) Dimensions (H x W x D) cm Inches Shipping Weight Kg Lbs
Model
Compressor Inlet Filter Element 220 V Compressor Service Kit 110 V Compressor Service Kit Pressure Switch Coalescing Filter Element Unloading Valve (230V) Unloading Valve (110V) Catalytic chamber Heater Element Thermocouple Temperature Controller Power Supply Solid State Relay (SSR) Cooling Fan (110V) Cooling Fan (230V) Transformer (230V Only)
ZA035-180A Issue 11
Parts List ZA035
02-4187 06-5530 06-5520 04-4411 02-4335 02-4334 02-4384 06-1075 04-1059 04-1051 04-4459 04-4460 04-4458 04-1022 04-1021 04-4356
ZA070
02-4187 06-5530 06-5520 04-4411 02-4335 02-4334 02-4384 06-1075 04-1059 04-1051 04-4459 04-4460 04-4458 04-1022 04-1021 04-4356
ZA180
02-4187 06-5530 06-5520 04-4411 02-4335 02-4334 02-4384 06-1075 04-1059 04-1051 04-4459 04-4460 04-4458 04-1022 04-1021 04-4356
13
10
ZA035-180A Issue 11
Heater Element Thermocouple Unloading Valve Heat Exchanger Pressure Regulator
Instructions for use Manual
System Diagrams
Zero Air
PEAK Scientific Instruments Ltd
Front Panel Membrane Dryer
Pressure Switch Catalytic Chamber Filter Separator
Outlet
Heat Exchanger
Receiver Compressor
ZAxxxA Pneumatic Diagram
Zero Air Gas Generator with Compressor th 12 October 2006
14
ZA035-180A Issue 11
Switch
12V Power Supply
L NE
Thermocouple Wire Green +ve, White -ve
Fuse
Instructions for use Manual
PEAK Scientific Instruments Ltd
12 11 10
9
8
7
6
5
4
3
2
1
Fan Motor SSR Front Panel LEDs Fan Motor Transformer (230V System)
Thermal Fuse
Thermocouple Wire Brown +ve, Blue -ve 1 2
Pressure Switch
Thermocouple
Heater Rod
Unloading Valve Compressor
ZA180A Electrical Diagram
Zero Air Gas Generator with Compressor th 12 October 2006
15
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Maintenance Log
ModelSerial number
Work Done
Remarks
Date
Name
ZA035-180A Issue 11
16
PEAK Scientific Instruments Ltd
Instructions for use Manual
Zero Air Gas Generator with Compressor th 12 October 2006
Notes
ZA035-180A Issue 11
17