PG Range User Manual
2021 © Peak Scientific - Rev. 10 - 03/03/2021
PG Range User Manual
Contents
Change History
3
How to Use This Manual
3
Introduction
4
Warranties and Liabilities
5
Safety Notices
6
Symbols
6
Safety Notice to Users
6
Environmental Declaration
8
Technical Specification
9
Environment
9
Outlet Gas
9
Electrical Requirements
9
General
9
Unpacking
Page 2
10
Contents
11
Unpacking Instructions
11
Installation
12
Generator Environment
12
Voltage and Power
12
General Dimensions
12
External Connections
14
Electrical Connection
15
Start-up Procedure
16
Normal Operation
18
Principal of Operation
18
Cleaning
18
Service Requirements
19
Routine Maintenance
19
Service Schedule
20
Service Plans
20
PG Range User Manual
Change History
Rev.
Comment
Name
Date
1
Initial release
Tracy Grierson
19/07/2007
2
Added details for PG85L
Tracy Grierson
06/03/2008
3
Content Update
Liam Couttie
01/05/2013
4A
Format Update
Liam Couttie
18/11/2014
5A
Content Update
Liam Couttie
25/01/2015
6
Content Update
Liam Couttie
07/08/2017
7
Chassis Updates
Liam Couttie
07/11/2017
8
Updates to incorporate CSA feedback
Liam Couttie
22/11/2017
9
Technical Correction
Liam Couttie
25/04/2018
10
Technical Correction
Liam Couttie
03/03/2021
How to Use This Manual
This manual is intended for end users and has been written so that it can either
be read as a step by step guide to installation and usage or as a reference
document where you can skip to the relevant information.
Users of a hard copy version can refer to the contents page to find the relevant
information. Users of the soft copy version can use the hyperlinks from the
contents page as well as the hyperlinks between sections.
Please review each of the following sections carefully.
Thank you for selecting Peak Scientific to meet your Gas Generation needs, and
should you require any further assistance or support please do not hesitate to
contact Peak Scientific or the Peak Partner from which you purchased your
Generator.
Page 3
PG Range User Manual
Introduction
Welcome to the User Manual for the Peak Scientific Purge Gas Range. Enclosed
in this manual you will find the information required to ensure that your Purge
Gas Generator is operated according to our recommended guidelines which
will prepare you for a long and trouble free life.
Attachable to any compressed air source, Peak Scientific’s Purge Gas
Generator offers a compact and lightweight must-have for any modern
laboratory. The Purge Gas Generators come with just a few moving parts and
are very sturdy products – ideal to prevent moisture contamination of any of
your applications.
Page 4
PG Range User Manual
Warranties and Liabilities
1. The Company warrants that it has title to the Goods.
2. Subject to the provisions of this clause the Company warrants that the
Goods shall comply in all material respects with any specification
referred to in the Order Confirmation (as the same may be amended)
and shall, subject thereto, be free from defects in material and
workmanship for the lesser of a period of twelve months from the date
of delivery or thirteen months from the date of dispatch from the
factory.
3. Save as provided in this clause and except where the Goods are sold to a
person dealing as a consumer (within the meaning of the Unfair Contract
Terms Act 1977) all warranties, conditions or other terms implied by
statute or common law are hereby expressly excluded save to the extent
they may not be lawfully excluded. When the Goods are sold to a
consumer within the meaning of the Unfair Contract Terms Act 1977 their
statutory rights are not affected by the provisions of this clause.
4. In the event of the Customer making a claim in respect of any defect in
terms of clause 2 hereof the Customer must.
1. Reasonably satisfy the Company that the Goods have been
properly installed, commissioned, stored, serviced and used and
without prejudice to the generality of the foregoing that any
defect is not the direct or indirect result of lack of repair and/or
servicing, incorrect repair and/or servicing, use of wrong
materials and/or incorrect spare parts
2. Allow the company to inspect the Goods and/or any installation
and any relevant packaging as and when reasonably required by
the Company.
5. Subject to the Company being notified of any defect as is referred to in
sub-clause 2 hereof within a reasonable time of it becoming apparent
and subject always to the terms of sub-clause 4 hereof, the Company
shall, in its option, replace or repair the defective Goods or refund a
proportionate part of the Price. The Company shall have no further
liability to the Customer (save as mentioned in sub-clause 6 hereof).
6. The Company shall be liable to indemnify the Customer in respect of any
claim for death or personal injury to any person in so far as such is
attributable to the negligence or breach of duty of the Company or any
failure by the Company to comply with the provisions of sub-clause 2
hereof.
7. Save as provided in sub-clause 2 hereof the Company shall not be liable
in respect of any claim by the Customer for costs, damages, loss or
expenses (whether direct, indirect, consequential or otherwise) or
indemnity in any respect howsoever arising including, but not by way of
limitation, liability arising in negligence (other than pursuant to clause 6
above) that may be suffered by the Customer or any third party.
Page 5
PG Range User Manual
Safety Notices
Symbols
This manual uses the following symbols to highlight specific areas important to
the safe and proper use of the Generator.
A WARNING notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause personal
injury or in the worst case death. Do not proceed beyond a WARNING notice until the
indicated conditions are fully understood or met.
A CAUTION notice denotes a hazard. It calls attention to an operating procedure,
process or similar, which if not correctly performed or adhered to, could cause damage
to the Generator or the Application. Do not proceed beyond a CAUTION notice until the
indicated conditions are fully understood or met.
Caution, risk of electric shock. Ensure power to the Generator has been removed before
proceeding.
Safety Notice to Users
These instructions must be read thoroughly and understood
before installation and operation of your Peak Generator. Use
of the Generator in a manner not specified by Peak Scientific
MAY impair the SAFETY provided by the equipment.
When handling, operating or carrying out any maintenance,
personnel must employ safe engineering practices and observe
all relevant local health and safety requirements and
regulations. The attention of UK users is drawn to the Health
and Safety at Work Act 1974, and the Institute of Electrical
Engineers regulations.
Page 6
PG Range User Manual
EU Declaration of Conformity
We
Peak Scientific Instruments Ltd.
Of
9RE
Fountain Crescent, Inchinnan, Renfrewshire, PA4
Declare that:
Equipment:
Dry Air Purge Gas Generators
Model:
PG14L & PG28L
To which this declaration relates, is in conformity with the applicable EC
directives, harmonized standards, and other normative requirements.
•
•
Low Voltage Directive 2014/35/EU
EN 61010-1: 2010 Electrical Equipment for measurement,
control and laboratory use.
Electromagnetic Compatibility Directive 2014/30/EU
EN 61326-1: 2013 Electrical Equipment for measurement,
control and laboratory use.
Year CE mark was first affixed 2017
All evaluation, testing and certification issued by:
York EMC Services Ltd
Unit 1, Grangemouth Technology Park,
Earls Rd, Grangemouth
FK3 8UZ
Signed:
Name:
Chris Pugh
Date: 14th November 2017
Position:
Chief Technology Officer
Page 7
PG Range User Manual
Environmental Declaration
We
Peak Scientific Instruments Ltd.
Of
9RE
Fountain Crescent, Inchinnan, Renfrewshire, PA4
Declare that:
Equipment:
Dry Air Purge Gas Generators
Model:
PG14L & PG28L
Is fully compliant with the following Directives and Regulations:
•
•
2012/19/EU WEEE (Waste Electrical and Electronic Equipment)
2011/65/EU RoHS (Restriction of Hazardous Substances in
Electrical Equipment)
Peak Scientific Instruments Ltd fully complies with its obligations towards the
European WEEE (Waste of Electrical and Electronic Equipment) Directive
2012/19/EU. These obligations are being met within the B2B compliance
group.
Peak Scientific Instruments Ltd has developed all reasonable ‘due diligence’
controls to ensure that our products comply with the principles and
requirements of the European RoHS (Restriction of Hazardous Substances)
Directive 2011/65/EU. Similar directives in the United States and China, for
example, have also been captured within this program.
Where a specific certificate of compliance is required, this can be requested, on
a product serial number basis, directly from Peak Scientific Instruments Ltd, by
contacting us through our website on www.peakscientific.com
Signed By :
Name: Chris Pugh
Position: Chief Technology Officer
Location: Peak Scientific Instruments Ltd, Inchinnan, Scotland. PA49RE
Date : 14th November 2017
Page 8
PG Range User Manual
Technical Specification
Environment
PG14L
Min/Max operating ambient temperature
PG28L
5°C (41°F)- 25°C (77°F)
Maximum relative humidity
70%
Inlet Conditions
Min/Max Air Inlet Pressure
Minimum Air Inlet Flow Rate
100psi/6.9bar-120psi/8.3 bar
26 l/min
53 l/min
Oil Content
<0.01mg per cubic meter
Min/Max Inlet Air Temperature
5oC (41o F)*- 25oC (77oF)*
*NOTE – When taken out of storage the Generator should be allowed to
acclimatize at room temperature for a minimum of 3 hours before operation.
Outlet Gas
Maximum Flow
28 l/min
14 l/min
Max Pressure
100psi/6.9 bar
Pressure Dewpoint
-70 °C / -94 °F
Particles
0.01 um
Start-up Time
16 hours
Electrical Requirements
PG14/28L Electrical Requirements
Electrical Connection
Pollution Degree
Universal 120 / 240 VAC - 50/60 Hz - 0.8A
IEC Euro Connector
2
Insulation Category
II
Replacement Fuse (UK only)
5A
General
Generator weight
PG14L – 14.4 kg (31.7 lb)
PG28L – 18.6 kg (41.0 lb)
Shipping weight
PG14L – 15.9 kg (35.0 lb)
PG28L – 20.1 kg (44.3 lb)
Page 9
PG Range User Manual
Unpacking
Although Peak Scientific takes every precaution with safe transit and
packaging, it is advisable to fully inspect the unit for any sign of transit
damage.
Check ‘SHOCKWATCH’ label for signs of rough handling prior to un-packing –
Any damage should be reported immediately to the carrier and Peak
Scientific or the Peak Partner from where the unit was purchased.
Follow the unpacking instructions posted on the side of the crate. It will require
two people to remove the unit from the shipping crate and to manoeuvre the
Generator onto the floor.
Please save the product packaging for storage or future shipment of the
Generator.
Note: Included with the Generator is a “Fittings Kit” containing mains power
leads for UK, EU and US also all the required fittings. Be careful not to discard
these with the packaging.
Page 10
PG Range User Manual
Contents
Each shipping box should contain the following: PG Generator
Mains Cable
Installation Guide
Unpacking Instructions
The PG 14L and 28L generator weigh approximately 14.4 and 18.6 Kg,
respectively, and as such should only be lifted using safe lifting practice.
1.
Open packaging, and remove foam.
2. Next, position your hands underneath the unit on either side, ready to
lift.
3. Ensuring your knees are bent and your back is straight, lift the unit to
the desired location.
Page 11
PG Range User Manual
Installation
Generator Environment
The Purge Gas Generator is designed for indoor use only. For
safety reasons, the unit requires to be wall mounted on a
steady and level surface. Please see enclosed Installation Guide
in the product packaging for correct installation instructions.
The minimum and maximum ambient operating temperatures are 5oC and 25oC.
Keep the unit in a well ventilated site away from direct sunlight.
Voltage and Power
The PG14/28L are fitted with an internal switch mode power
supply that will accept a power inlet from 100VAC - 240VAC,
50/60HZ. The current consumption is 80 mA.
Please ensure generator is positioned so as to permit easy disconnection if
required.
General Dimensions
PG14L
459.3
660
Page 12
162
196
582
PG Range User Manual
PG28L
459.3
910
Page 13
162
100
840
PG Range User Manual
External Connections
Connect the unit to a suitable electrical supply.
Attach a suitable air supply to the inlet port of the filter.
Note that the inlet and outlet air connections are ¼” BSP Female.
Attach the outlet of the generator to your instrument and ensure that you do
not draw any more than the specified amount of purified air from the system.
Input Filter
Input Port ¼” BSP Female
Page 14
Outlet Filter
Outlet Port ¼” BSP Female
PG Range User Manual
Electrical Connection
Connect the Generator to an appropriate 110 - 230 volt single-phase supply,
refer to the generator serial plate for input specification and ensure your supply
matches the requirements.
If the appropriate power cord is not supplied; a new plug, rated to at least 12
amps, can be fitted by a qualified electrician.
This unit is classified as SAFETY CLASS 1. THIS UNIT MUST BE
EARTHED. Before connecting the unit to the mains supply,
please check the information on the serial plate. The mains
supply must be of the stated AC voltage and frequency.
EARTH/GROUND (E):-
Green & Yellow
or
Green
LIVE (L)/PHASE (P):-
Brown
or
Red
Neutral (N):-
Blue
or
Black
Electrical requirements are 110 - 230VAC nominal +/- 10% depending on chosen
model. However, running continuously at voltages outwith this is not
recommended. Extended periods at extremes can have a detrimental effect on
the operation and life of the Generator.
If a substitute main supply cord is used, ensure that it has an adequate rating.
Failure to do so could cause damage to the generator.
The PG14/28L are fitted with an internal switch mode power
supply that will accept a power inlet from 100VAC - 240VAC,
50/60HZ. The current consumption is 80 mA.
Page 15
PG Range User Manual
Start-up Procedure
Connect the fitting to the input of the filter on the generator and connect to
your in house air supply. Restrict output to the manufacturer specification.
Ensure that the power to the Purge Gas Generator is turned on before starting
the air supply. Gradually introduce air pressure to the unit until the
recommended pressure has been reached.
Allow unit to vent to atmosphere for 16 hours before connecting to any
equipment.
The system is now operational and requires no further intervention.
Page 16
PG Range User Manual
Go Online or Complete and Return
We know that registering any of your recently purchased products is not the first
thing on your mind- but it is very important to both of us. Not all warranties are
alike and Peak Scientific stand out against other gas suppliers as we offer a
comprehensive, quick response, on-site warranty. This means that in the very
unlikely case that your gas generator develops a fault we have rapid support teams
on-hand around the world who are able to come to your lab and get you back up
and running in no time.
Register for your comprehensive 12 month on-site warranty with ease online at
www.peakscientific.com/register.
Alternatively, you can send the completed form to Peak Scientific by post or email
at warranty@peakscientific.com.
Important!
You have 1 month to register your Peak Scientific product from the date of
installation. Once registered the warranty will be honoured for a period of 12
months. If you wish to defer the installation of your generator, you must notify Peak
Scientific immediately by emailing warranty@peakscientific.com. For generators
that remain unregistered after 1 month from the shipment date, the warranty will be
considered active from the date of factory dispatch.
Page 17
PG Range User Manual
Normal Operation
Principal of Operation
The Purge Gas Generator works using Pressure Swing Adsorption (PSA).
PSA works on the principle that an adsorbent (such as the activated alumina
used in the PG series) has a differential adsorbing capacity at high and low
pressure. The Purge Gas Generator consists of two columns of adsorbent, one
at high pressure which adsorbs CO2 and moisture from compressed air, and
another at low pressure. The low-pressure column is fed with a slipstream of
the moisture and CO2-free air, known as the purge flow. This purge flow assists
in the regeneration of the adsorbent. After a fixed time, known as the “swing
time”, the high-pressure column depressurises and the pressure increases in the
low-pressure column. What was the low-pressure, regenerating column, then
assumes the role of the high-pressure adsorbing column, with the high pressure
column adopting the role of the low pressure, regenerating column. This
reversal of the roles of the columns can continue indefinitely rendering the
adsorbent columns maintenance free.
Cleaning
Clean the outside of the Generator only using warm soapy water and a clean
damp cloth. Ensure all excess fluid is thoroughly removed from the cloth prior
to use.
Cleaning should only be undertaken with the power switched
off and the power cord removed from the rear of the Generator.
Under no circumstances should any solvents or abrasive
cleaning solutions be used as these can contain fumes that
could be harmful to the Generator.
Page 18
PG Range User Manual
Service Requirements
Routine Maintenance
Servicing and/or repair of the Generator should only be
undertaken by a TECHNICALLY COMPETENT PERSON, with the
generator in its safely isolated condition.
Safely Isolated Condition; The unit is in a Safely Isolated
Condition when it is disconnected from its application, fully depressurised and isolated from the Electrical Supply. Directions
for isolating the generator are shown below.
Isolating the Generator
a. Switch off the unit.
b. Disconnect the unit from the mains supply.
c. Disconnect from the application.
Page 19
PG Range User Manual
Service Schedule
Service Interval
12 Months
Component
Inlet/Outlet Coalescer Filter Element
Inlet RAC Filter Element
Exhaust Silencers
Part No.
00-4424
00-4427
02-1033
Qty.
2
1
1
As an alternative to purchasing the 12 month service items individually an
Annual Service Kit is available as one part number. This contains all the filters
required for this Generator and offers a cost saving over buying the
components separately.
Purchase Interval
Component
Part No.
Qty.
12 months
PG14-28L- Annual Service Kit
08-8222
1
Service Plans
Peak Scientific offer two service plans. The Complete Service Plan, specifically
designed for Generators operated in critical environments, also includes full
breakdown cover, guaranteed response times and Generator upgrades if
available. Our Standard Service Plan, covering the basic needs of our
Generators, features special deals on spare parts and breakdowns.
If you want to know more about our Service Plan options and how we ensure
that your instrument can run with the maximum uptime and performance,
please contact us at maintenance@peakscientific.com
Page 20
Peak Scientific UK
Fountain Crescent
Inchinnan Business Park
Inchinnan
PA4 9RE
Scotland, UK
Peak Scientific North America
19 Sterling Road
Suite #1
Billerica, MA 01862
Peak Scientific Africa
PO Box 478
Somerset Mall
7137
USA
Peak Scientific India
202, Amsri Shamira
Old Lancer Line
Opp. St. Mary’s Degree College
S.D. Road Secunderabad
500 025, India
Tel: +44 (0)141 812 8100
Fax: +44 (0)141 812 8200
Tel: +1 866 647 1649
Fax: +1 978 608 9503
Tel: +91 40 2780 0663
Fax: +91 40 2780 0663
Tel: +27 (0)2185 16542
Fax: +27 (0)8654 64473
Peak Scientific Germany
Herriotstrasse 1
60528 Frankfurt
Peak Scientific Mexico
Solon 352
Col. Los Morales Polanco
11530 Mexico, D.F.
Peak Scientific Australia
PO Box 65
Belmont
Victoria 3216
Germany
Peak Scientific China
Room 606 Building 1
Lane 2277 Zuchongzhi Road
Pudong New Area
Shanghai
201203, China
Mexico
Australia
Tel: +49 (0)69 677 33 490
Fax: +49 (0)69 677 33 200
Tel: +86 21 5079 1190
Fax: +86 21 5079 1191
Tel:
Fax:
Tel:
Peak Scientific Taiwan
4F.-6, No.736
Zhongzheng Rd.
Zhonghe Dist.
New Taipei City
Peak Scientific Brazil
Peak Scientific Brasil
Av. Quieroz Filho
1700 – torre Sunny-Conj. 602
São Paulo SP Brasil
Peak Scientific Japan K.K.
2-7-56, 2F Fuji Building 28
Kita Aoyama, Minato-Ku
Tokyo, Japan
107-0061
Peak Scientific Singapore
3 Science Park Drive
#03-14 The Franklin
Science Park Drive 1
Singapore, 118223
Tel: +886 2 8226 2383
Fax: +886 2 8226 9499
Tel: +1 866 647 1649
Tel: +81 3-6864-0468
Tel: +65-6777 1966
Fax: +65-6777 1978
+1 866 647 1649
+1 978 608 9503
South Africa
+61 1300 965 352