Rev 6 - 11/04/2024

EU Declaration of Conformity
UK Declaration of Conformity

9
10
11
13
14
14
14
15
16
18
18
19
20
20
20
21
21
21
22
23
24
25
26
27

Page 2

28
29
30
31
32
33
34
35
CSA Compliance Statement

36

Supported Maintenance Guide

37

(Infinity 5010 - 40 & 9010 - 40 series)

Service Parts List

38

(Infinity 5010 - 40 & 9010 - 40 series)

Supported Maintenance Guide

39

(Infinity 5050 - 80 & 9050 - 80)

Service Parts List
(Infinity 5050 - 80 & 9050 - 80)

Page 3

40

6

SMG Guide Added

Page 4

Cleo Denholm

24/06/2024

Page 5

Page 6

Page 7

EU Declaration of Conformity

•

Low Voltage Directive 2014/35/EU

•

Electromagnetic Compatibility Directive 2014/30/EU

•

Restriction on the use of certain hazardous substances in electronic equipment
(RoHS) Directive 2011/65/EU as amended by EU 2015/863.

•

FCC 47 CFR Part 15 class A

Page 8

UK Declaration of Conformity

•

The Electrical Equipment (Safety) Regulations 2016 (SI 2016 / 1101) as amended.

•

The Electromagnetic Compatibility Regulations 2016 (SI 2016 / 1091) as amended.

•

The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012 (SI 2012 / 3032) as amended.

Page 9

WEEE Compliance Statement

Page 10

Page 11

Page 12

Page 13

Page 14

Page 15

Page 16

Page 17

½

Page 18

Page 19

Page 20

Page 21

Page 22

Page 23

Page 24

Page 25

Page 26

Page 27

Page 28

Page 29

Page 30

Page 31

Page 32

Page 33

Page 34

Page 35

CSA Compliance Statement
CSA Group is a Nationally Recognised Testing Laboratory (NRTL) in the U.S. and an
Accredited Certification Organisation (ACO) by Standards Council of Canada (SCC) in
Canada. They are qualified to test to CSA Group (CSA), American National Standards
Institute (ANSI), American Society of Mechanical Engineers (ASME), American Society
for Testing and Materials (ASTM), American Society of Sanitary Engineers (ASSE),
National Sanitation Foundation (NSF), Underwriters Laboratories (UL) and other
standards writing bodies.
All PEAK products that are subject to the CSA directive are compliant with the CSA
marking requirement. Such products are marked with the “CSA” symbol (shown below)
in accordance with CSA directives.

Page 36

Supported Maintenance Plan
Infinity 5010 - 40 & 9010 - 40 series

Introduction
The following is a guide for maintenance of the Infinity 5010-40 & 9010-40 series Nitrogen
Generator as provided for by the Peak Service Plan.

This procedure is to be performed on an annual basis.
1. Check that the LC/MS is not in use and that it is OK to disconnect the Gas Supply.
Check that the Gas Demand is turned OFF.
2. Shut the Air Supply Valve and turn the Generator OFF.
3. Remove both the side Access Panels.
4. Carefully open the RAC filter drain allowing the generator to slowly de-pressurize.
Confirm that the gauges return to Zero. Any pressure gauge that does not return
to zero may be damaged and must be replaced.

5. Replace the RAC Filter Element and re-assemble the filter.

Page 37

6. Unscrew the top and bottom covers from the breathing air filter.
7. Replace the Breathing Air Filter Elements.

8. Re-assemble the breathing air filter.
9. Carefully open the Air Supply Valve and turn the Generator ON.
10. Switch the LC/MS gas demand ON.

Service Parts List
Service Parts List 5010-40 & 9010-40

Part Number

Description

3302283 (00-0041*)

RAC Filter Element

1

3302280 (00-0042*)

Coalescing Element for BA Filter

1

3302281 (00-0043*)

Active Carbon Element for BA Filter

1

Quantity

Element part numbers with (*) are obsolete the 330228X part number should be ordered

Page 38

Supported Maintenance Plan
Infinity 5050 - 80 & 9050 - 80

Introduction
The following is a guide for maintenance of the Infinity 5050 -80 & 9050-80 Nitrogen
Generator as provided for by the Peak Service Plan.

This procedure is to be performed on an annual basis.
1. Check that the LC/MS is not in use and that it is OK to disconnect the Gas Supply.
Check that the Gas Demand is turned OFF.
2. Shut the Air Supply Valve and turn the Generator OFF.
3. Remove both the side Access Panels.
4. Carefully open the RAC filter drain allowing the generator to slowly de-pressurize.
Confirm that the gauges return to Zero. Any pressure gauge that does not return
to zero maybe damaged and must be replaced.

5. Replace the RAC Filter Element and re-assemble the filter.

Page 39

6. Unscrew the top and bottom covers from the breathing air filter.
7. Replace the Breathing Air Filter Elements.

8. Re-assemble the breathing air filter.
9. Carefully open the Air Supply Valve and turn the Generator ON.
10. Switch the LC/MS gas demand ON.

Service Parts List
Service Parts List 5050-80 & 9050-80

Part Number

Description

Quantity

3302283 (00-0041*)

RAC Filter Element

1

3302280 (00-0042*)

Coalescing Element for BA Filter

2

3302281 (00-0043*)

Active Carbon Element for BA Filter

2

Element part numbers with (*) are obsolete, the 330XXXX part number should be ordered.